ANALOG DEVICES ADE8165 Service Manual

Narrow-Band Power-Line Communications
ADE8165
PLC_RX+
PLC_RX–
12-BIT
ADC
DEMODULATOR
MODULATOR
DAC
PLC_TX
37
38
6
PHY
ZX
20
RX_LED
11
TXEN
21
DLL
UART
EXTERNAL
MEMORY
INTERFACE
NL
WITH NETWORK
MANAGEMENT FUNCTIONS
RX TX RS485_OE EVENT
10
V
DD
15
LDO
V
INTD
16
DGND
14
DGND
17
RST
19
AVDD36AGND35V
REF
34
AGND
ADE8165
5
RXEN
33
XTAL0
24
XTAL1
25
OSC
VMON
39
07841-001
22
23
A1/MISO SPISCLK
30
A0/MOSI
27
SPICSL
26
28 29
Master Modem IC with Networking Stack

FEATURES

Narrow-band power-line communications IC
Integrates PHY through networking layer Simple host interface
Application layer
Supports DL/T 645-1997 or -2007 China-specific protocol as well as passthrough option
Networking layer
Master/slave architecture Designed to work with ADE8155 slave PLC modem ICs Supports
Dynamic routing Automatic discovery of authenticated devices Logical address management
Data link layer
Automatic baud rate negotiation Up to 63-byte packet support
Physical layer
CPFSK modulation Choice of two frequency bands
Carrier frequencies: 105.5 kHz and 118.7 kHz Carrier frequencies: 74.9 kHz and 84.2 kHz
Up to 800 bps on a 1-phase network and 2400 bps on a
3-phase network Zero-crossing synchronized receive/transmit 6-byte physical address for logical address assignment
Communication interface
UART Option to use DL/T 645-1997 or -2007 China-specific application layer interface
Package and temperature range
40-lead 6 mm × 6 mm LFCSP Fully specified for −40°C to +85°C operation

GENERAL DESCRIPTION

The ADE8165 incorporates a high performance ADC and DAC to create a very robust CPFSK power-line communications IC complete with networking functionality. The ADE8165 master modem IC is designed to work with the ADE8155 slave modem IC for a complete power-line communication system.
In an advanced metering infrastructure (AMI) scenario, the ADE8155 slave modem IC is used to connect the energy meter to the power line. Then the ADE8165 master PLC modem is used near the transformer to communicate with multiple meters on one phase. The power-line communication is independent on each phase; therefore, three ADE8165 master PLC modem ICs are used in a PLC module within the concentrator to read meters on all three phases.
A UART communication interface is supported.
For more information on the ADE8165, contact your local sales office at Analog Devices, Inc.