FEATURES
Narrow-band power-line communications IC
Integrates PHY through networking layer
Simple host interface
Application layer
Supports DL/T 645-1997 or -2007 China-specific protocol
as well as passthrough option
Networking layer
Master/slave architecture
Designed to work with ADE8155 slave PLC modem ICs
Supports
Dynamic routing
Automatic discovery of authenticated devices
Logical address management
Data link layer
Automatic baud rate negotiation
Up to 63-byte packet support
Physical layer
CPFSK modulation
Choice of two frequency bands
Carrier frequencies: 105.5 kHz and 118.7 kHz
Carrier frequencies: 74.9 kHz and 84.2 kHz
Up to 800 bps on a 1-phase network and 2400 bps on a
3-phase network
Zero-crossing synchronized receive/transmit
6-byte physical address for logical address assignment
Communication interface
UART
Option to use DL/T 645-1997 or -2007 China-specific
application layer interface
Package and temperature range
40-lead 6 mm × 6 mm LFCSP
Fully specified for −40°C to +85°C operation
GENERAL DESCRIPTION
The ADE8165 incorporates a high performance ADC and
DAC to create a very robust CPFSK power-line communications
IC complete with networking functionality. The ADE8165
master modem IC is designed to work with the ADE8155 slave
modem IC for a complete power-line communication system.
In an advanced metering infrastructure (AMI) scenario, the
ADE8155 slave modem IC is used to connect the energy meter
to the power line. Then the ADE8165 master PLC modem is
used near the transformer to communicate with multiple
meters on one phase. The power-line communication is
independent on each phase; therefore, three ADE8165 master
PLC modem ICs are used in a PLC module within the
concentrator to read meters on all three phases.
A UART communication interface is supported.
For more information on the ADE8165, contact your local sales
office at Analog Devices, Inc.
FUNCTIONAL BLOCK DIAGRAM
Rev. Sp0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
Figure 1.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113 ©2010 Analog Devices, Inc. All rights reserved.