Amx MSD-431 User Manual

QUICK START GUIDE
Sleep Button Microphone
Left LED
Right
LED
Backbox
(side view)
Locking tab
Locking tab
Press down on the bottom edge (now pointed upwards)
Rotate Backbox back and lift off of panel
Invert Backbox/panel on a soft surface
with thumbs to release panel
1
2
3
Backbox
Backbox knockouts (X2)
Locking tabs (X2)
Flange holes for optional securing screws (not included)

Overview

The MSD-431-L 4.3" (Landscape) Wall Mount Touch Panel (FG2265-03) features brilliant 24-bit color depth, PoE connectivity, and streaming video, and supports Bluetooth keyboard and mouse via the optional MXA-BT Bluetooth Adapter.
FIG. 1 MSD-431-L
MSD-431-L SPECIFICATIONS
Dimensions (HWD) 3 3/8" x 5 1/16" x 2 5/8" (86mm x 128mm x 66mm)
Weight • 0.65 lbs (.295 Kg), with Backbox
Power Consumption • Full-On: 5W (max)
External Power Supply Required
Certifications • FCC Part 15 Class B
Environmental • Temperature (Operating): 32° F to 104° F (0° C to 40° C)
Included Accessories
• 0.5 lbs (.225 Kg), without Backbox
•Typical: 3W
• Standby: 2W
Optimal performance requires use of one of the following AMX PoE power supplies (not included):
• PS-POE-AF-TC, PoE Injector, 802.3AF Compliant (FG423-83)
• NXA-ENET8-2POE, Gigabit PoE Ethernet Switch (FG2178-63)
• CE EN 55022, 55024, 60950­1
• IEC 60950-1
• IC CISPR 22 Class B
• Temperature (Storage): 4° F to 140° F (-20° C to 60° C)
• Humidity (Operating): 20% to 85% RH
• Humidity (Storage): 5% to 85% RH
• Power ("Heat") Dissipation: On: 13.6 BTU/hr Standby: 10.9 BTU/hr
• Installation Template 4.3" S Series (68-2265-02)
• Shutdown: 0.7W
• Start-Up Inrush Current: Not applicable due t o Po E st an dard
• C-Tick CISPR 22 Class B
• UL 60950-1
• VCCI CISPR 22 Class B
•RoHS
•WEEE

Power Over Ethernet

Power for the MSD-431-L is supplied via Power Over Ethernet (PoE), utilizing an AMX-certified PoE injector such as the PS-POE-AF-TC PoE Injector (FG423-83) or other approved AMX PoE power source. The incoming Ethernet cable should be connected to the RJ-45 port on the MSD-431-L.

MSD-431-L Installation

The MSD-431-L may be installed as either a retrof it installation in to drywall or other similar
thickness material. (0.5" minimum), or inserted into the rough in box or rack mount kit. Once
installed, the MSD-431-L is contained within a clear outer housing known as the Backbox (FIG. 2). The clear plastic Backbox is designed to attach the panel to most standard wall materials.
The Backbox is removed from the panel prior to installing it into a wall or removed to use the optional Multi Mount accessory MSA-MMK-43 (FG2265-13).
Note: For typical mounting surfaces, such as drywall, use the locking tabs as the primary method for securing the Backbox to the surface. For thin walls or solid surfaces, use mounting screws (not included).
FIG. 2 MSD-431-L BACKBOX
MSD-431 4.3" Modero S

Removing the MSD-431-L Backbox

The clips on the bottom edge of the Backbox lock down the MSD-431-L and must be unlatched in order to remove the Backbox from the touch panel.
1. Hold the Backbox/panel inverted on a soft surface with the panel facing away from you.
2. Press down on the top edge of the Backbox to flex it and unhinge the touch panel.
FIG. 3 MSD-431-L BACKBOX REMOVAL
3. Rotate the top of the Backbox away from the panel and lift it away from the touch panel.
Note: For additional information on removing the Backbox on the MSD-431-L panel after wall mount installation has been completed, refer to the S-Series Touch Panels Instruction Manual.

Backbox Considerations

Note: For flat surface mounting the touch panels to glass, marble, or other smooth surfaces without drilling or cutting, refer to the MSA-MMK-43 (FG2265-13) Multi Mount Kit documentation at www.amx.com.
The Backbox has two locking tabs (one on top and one on bottom) to help lock the Backbox to the wall. Extend these locking tabs AFTER the Backbox is inserted into the wall.
FIG. 4 MSD-431-L
• When installing the Backbox, make sure that the assembly is in the correct position (arrow up) and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be difficult without having access to the back o f the wall or causing damage to the wall.
• In order to ensure a stable installation of the MSD-431-L, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm). The mounting surface should also be smoo th and flat.

Installing the Backbox

Use the included Installation Template (68-2265-02) to ensure proper placement.
Warning: Using the Installation Template to select the final placement of the Backbox is highly recommended. The outside edges of the template are the same dimensions as the touch panel, which allows you to troubleshoot possible conflicts with wall edges, doors, and other potential obstacles.
1. Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.
2. After ensuring proper placement, cut out the mounting surface for the Backbox, using the (included) Installation Template as a guide.
CAUTION: Making sure the actual cutout opening is slightly smaller than the provided dimensions is highly recommended. This provides a margin of error if the opening needs to be expanded. Too little wall material removed is always better than too much.
3. Thread the incoming Ethernet and Micro-USB wiring (if Micro-USB access is desired) from their terminal locations through the surface opening (FIG. 5).
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
4. Remove the Backbox knockouts (FIG. 4) and thread the incoming wiring through the knockout holes.
5. Thread the incoming Ethernet and Micro-USB wiring (if USB or Micro-USB access is desired) from the surface opening and through the knockouts.
Note: The Micro-USB port cannot be used while the touch panel installed in th e Back box . The MSD-431 must be removed from the wall and the Backbox in order to access the Micro-USB port.
6. Push the Backbox into the mounting surface ensuring that the locking tabs lie flush against the Backbox and that the Backbox goes freely into the opening.
7. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug.
®
Series Wall Mount Touch Panel
93-2265-03 REV: J
FIG. 5 MSD-431-L BACKBOX INSTALLATION
Knockout
Backbox
Locking tab
RJ45
Port
Micro-USB
Port
CAUTION: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the tab screws, such as with powered screwdrivers, can strip out the locking tabs or damage the Backbox.
• Apply enough pressure to the screw head to keep the box flush with the wall: this ensures that the locking tabs will tighten up against the inside of the wall.
• The Backbox is clear to allow visual confirmation that the tabs have been extended and are gripping the wall, as well as in assisting with removal if necessary.
• For additional strength, #4 mounting screws (not included) may be secured through circular holes located at the left and right flanges of the MSD-431-L (FIG. 5). In order to prevent damage to the touch panel, make sure that these are flush with the Backbox.

Installing the Touch Panel

1. Insert each connector into its corresponding location along the back of the device (FIG. 6).
FIG. 6 REAR OF THE MSD-431-L IN A BACKBOX
2. Attach the panel connections to their terminal locations and applying power to test wiring.
Note: Do not disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before being inserted into the mounting surface.
• Verify that the panel is receiving power and is functioning properly.
• Remove power before continuing with the installation.
3. Latch the panel onto the top hoo ks on the Backbox and push it down onto the bo ttom snaps. Press gently but firmly on the ends until the snaps “click” to lock it down.
Note: If a gap is observed between the panel and the Backbox, or binding is felt while locking down the panel, stop and verify there are no cables in the way. Do not force the panel into position, or the touch screen or the panel electronics may be damaged.
4. Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master.

Conf iguring and Programming

S Series touch panels are equipped with a Settings menu that provides the ability to set and configure various features on the panels. To access the Settings menu, press and hold the Sleep button on the top of the panel for 3 seconds. This invokes an on-screen prompt to release the button to enter the main Settings page.

Accessing the Configuration Page

1. From the Settings menu, select Configuration. If the Configuration page is password protected, this opens a password keypad.
2. Enter the panel password into the keypad (the default is 1988) and select OK to access the page.
• To reboot the panel, press and hold the text under the Reboot section for two seconds.
• To shut down the panel, press and hold the text under the Shutdown section for two seconds.

Setting the Panel’s Device Number and Device Name

In the Configuration page:
1. Press Panel to open the Panel Conf iguration page.
2. In the Device Name page, ensure that the Synchronize Device Names button is not selected, and click it to deselect it if it is.
3. Press Device Number to open the Device Number keypad.
4. Enter a unique Device Number assignment for the panel and press OK.
5. Press the Device Name field to open the Device Name keypad.
6. Enter a unique Device Name assignment for the panel and press OK.
7. Click the arrow on the top left of the page once to return to the Configuration page and twice to return to the Settings page.

Accessing the Connection & Networks Page

1. From the Settings menu, select Connection & Networks. If the page is password protected, this opens a password keypad.
2. Enter the panel password into the keypad (the default is 1988) and select OK.

Conf iguring the Panel’s IP Address

The first step is to conf igure the panel’s communication parameters. This only conf igures the panel to communicate with a network, and it is still necessary to tell the panel with which Master it should be communicating.
Network Communication With a DHCP Address
In the Connection & Networks page:
1. Select Network Connection to open the Network Connection page.
2. Toggle the DHCP/Static field until the choice cycles to DHCP. This action causes all fields on the page (other than Host Name) to be greyed-out.
3. Select Host Name to open the Host Name keyboard. Enter the new host name and click
OK.
Setting Static IP Information
When usi ng DHCP settings for a panel, the DHCP server will automatically populate almost all of the Network Connections page fields, with the exception of Hostname. When setting the panel for Stati c, however, this information must be entered manually. To enter the network connection information:
1. In DHCP/Static, press the field until the entry reads “Static”. This enables all of the editable Network Connections page fields.
2. Select the IP Address field to open the Wire d IP Address keypad.
3. Enter the server’s IP address and click OK.
4. Repeat this procedure with the other fields on the Network Connections page.
5. When finished, the new connection information will be visible in the Network Connections page.

Connecting to a NetLinx Master

To establish the type of connection to make between the panel and NetLinx Master:
1. In the Connection & Networks page, select Master Connection to open the Master Connection page.
2. Press Mode to toggle through the available connection modes (Auto, URL or Listen):
CONNECTION MODES
Mode Des cription Procedures
URL The device connects to the target
Master’s IP address via a TCP connection.
Listen This mode allows the panel to
“listen” for the Master’s communication signals. Note that in this mode, the System Number and Master IP/URL fields are read-only.
Auto Use this mode when both the panel
and the NetLinx Master are on the same Subnet.
3. If you have enabled password security on your Master, you need to set the username and password within the device.
a. Select Username to open the Master User keyboard. b. Set your Username and select OK. c. Select the Password to open the Master Password keyboard. d. Set your Master Password and select OK. e. Press the Back button twice to return to the Settings page.

Related Software and Additional Documentation (at www.amx.com)

• Programming the Modero S Series touch panels requires the use of the latest versions of NetLinx Studio and TPDesign4, both available to download at www.amx.com. Refer to the NetLinx Studio and TPDesign4 online help for information.
• For additional information on the MSD-431-L panel, refer to the S-Series Touch Panels
MSD/T-1001, MSD/T-431 & MSD/T-431 Instruction Manual.
• For detailed information on the Settings menu as well programming information and instructions on upgrading firmware, refer to the Modero S Series Programming Guide.
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port Number, and Username/Password (if required by the Master).
3) Press OK to save changes.
1) Select Listen in the Mode menu.
2) Confirm the panel’s IP address is on the Master’s URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name can be used to locate the panel on the Master (particularly useful for DHCP connections where the IP address can change).
1) Select Auto in the Mode menu.
2) Enter the System Number and Username and Password (if applicable).
3) Press OK to save changes.