AMX RDA-ENC6B, RDA-ENC12B, ENC12B User Manual

Installation Guide
RDA-ENC6B and ENC12B Dimmer Enclosures w/Breakers
The RDA-ENC6B (FG606-13) and RDA-ENC12B (FG606-14) enclosures provide secure mounting for all AMX Lighting and ProLink controllers, and lighting modules. These enclosures contain circuit breakers.
TOP VIEW
0.75"
(19.05 mm)
6.0"
(152.4 mm)
SIDE VIEW
RDA-ENC6B
24.0"
(610 mm)
18.0"
(457.2 mm)
24.0"
(610 mm)
RDA-ENC12B
Top, side, and bottom views are the same for both enclosures.
These enclosures are CE, UL, and C-UL approved. They include circuit breakers and terminals for multi-phase wiring.
They also provide 18 knockouts for 1/2", 3/4", and 1" conduits.
RDA-ENC6B Configurations:
- ENC6B/120 20 A Breakers
- ENC6B/240 10 A Breakers
RDA-ENC12B Configurations:
- ENC12B/120 20 A Breakers
- ENC12B/240 10 A Breakers
RDK Configurations:
- RDK-ENC6B with 1 RDC-PDC
- RDK-ENC12B/240 2 RDC-PDC
Sample RDK-ENC12B kit shown with 2 RDC-PDC
Note:
LINE INPUTS: 120 A MAX PER TERMINAL
Use 75° C copper conductors only. Torque terminals to 44 in-lbs.
BOTTOM VIEW
FIG. 1 Top, front, bottom, and side views of the RDA-ENC6B and RDA-ENC12B enclosures
• For indoor use only.
• Mount on vertical surface only.
• Maintain 12" (304.88 mm) minimum clearance above and below the enclo­sure.
• Route class 1 conductors through upper conduit knockouts.
• Route class 2 conductors through lower conduit knockouts.
• Use 75°C (167°F) copper conductors only.
• Install filler plate #28-10500 (RDA-EFP) in all unused openings.
• Install only UL approved modules (see the UL Number Cross Reference to AMX Lighting ID table on page 2).

Enclosure Weights:

• RDA-ENC6B: 16.5 lbs. (7.48 kg)
• RDA-ENC12B: 17.5 lbs. (7.94 kg)

Dimensions between center lines (from FIG. 2):

RDA-ENC6B:
• A to B = 16.0" (406.4 mm)
• B to C = 22.88" (581.2 mm)
RDA-ENC12B:
• A to B = 16.0" (406.4 mm)
• B to C = 22.88" (581.2 mm)
Radia enclosures must be mounted on a vertical surface with a minimum of 12" (304.8 mm) clearance above and below the enclosure.
Configuration for right and left mounting brackets for all Radia enclosures.
Maximum mounting screw size: #12
FIG. 2 Bracket configuration
Top sl ot
Bottom slot
A to B
B to C

Specifications

• Maximum input wire #1/0 AWG (50mm²)
• Maximum line input is 120 A (per terminal)
• Torque input wire to 44 in-lbs. (5.0 N/m)
• Wire stripping length: 0.67 inches (17 mm)
• Input 1 feeds channels 1, 4, 7, and 10
• Input 2a feeds channels 5 and 11
• Input 2b feeds channels 2 and 8
• Input 3 feeds channels 3, 6, 9, and 12
• Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty, Hydraulic-Magnetic
The following section cross references the UL ID module numbers and AMX Lighting module IDs.
The modules identified are the only ones that can be used in the RDA-ENC6B and RDA-ENC12B enclosures.
UL Number Cross Reference to AMX Lighting ID
UL ID AMX ID UL ID AMX ID UL ID AMX ID
28-10100 RDC-DC/120 28-10200 RDM-INC 28-10300 RDM-MR60
28-10110 RDC-DC/240 28-10210 RDM-2INC 28-10310 RDM-MDM
28-10120 RDC-DC/277 28-10220 RDM-INC50 28-10340 RDA-CHK
28-10130 RDC-PDC/120 28-10230 RDM-ZC,
28-10133 RDC-PDC/240 28-10240 RDM-ZC50 28-10360 RDM-DPSM
RDM-2ZC
28-10350 RDM-FDB
RDM-2FDB RDM-3FDB RDM-HFDB

Lighting Application Drawings

UL Number Cross Reference to AMX Lighting ID (Cont.)
UL ID AMX ID UL ID AMX ID UL ID AMX ID
28-10140 RDD-DM6/120 28-10260 RDM-SWM,
28-10150 RDD-DM6/240 28-10270 RDM-HSW,
28-10160 RDD-DM6/277
28-10170 RDA-PSM/120
RDM-2SWM, RDM-3SWM
RDM-2HSW, RDM-3HSW
28-10370 RDM-DC,
RDM-2DC, RDM-3DC
RDM-HDC
FIG. 3 ENC6B and ENC12B Power Distribution
Note:
LINE INPUTS: 120 A MAX PER TERMINAL
Use 75° C copper conductors only. Torque terminals to 44 in-lbs.
FIG. 4 ENC6B and ENC12B Input Terminal Block Wiring
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
AMX reserves the right to alter specifications without notice at any time.
93-0606-13 REV: B
10/08
Loading...