Amtrol WELL-X-TROL User Manual 2

Page 1
WELL-X-TROL PROFESSIONAL
Pre-Pressurized
Water System
Tanks
Page 2
WELL-X-TROL®Professional
the industry
WELL-X-TROL®Professional redefined the industry with its advanced engineering and
innovative product design including the pre-pressurized well tank, sealed-in air charge,
and unique water chamber design. With proven performance since 1963, WELL-X-TROL
Professional continues to deliver unparalleled results making it
of professionals
that result in consistent, reliable performance, including design elements that prevent tank
corrosion and reduce wear and tear on the well pump.
Features and Benefits
Exclusive butyl diaphragm, along with the 100% corrosion resistant virgin polypropylene liner, are secured by a positive hoop ring seal for added strength and reliability. This totally integrated system outperforms other types of water chamber designs.
in today’s market.WELL-X-TROL Professional offers many unique features
the most trusted choice
The stainless steel air valve is welded rather than threaded to prevent loss of air pressure.
The finest quality, custom mill steel is used in the deep drawn dome
for extra strength while keeping tank weight to a minimum.
More choices mean more flexibility
WELL-X-TROL Professional offers more options and sizes
than any other well tank manufacturer, including both
vertical and horizontal designs, and sizes ranging
from 2 gallons to 119 gallons so you can
configure a system that’s right for any application.
First on Industry Safety Standards
WELL-X-TROL Professional tanks were the first to meet all industry standards for quality
The butyl diaphragm in all models
and safety meets EPA requirements for potable water as defined in the Safe Drinking Water Act of
1986. The entire tank which includes the gin polypropylene liner
vir
and acceptance fittings for a 100% corrosion
resistant water reservoir is listed by NSF International Standard 61.
.
, butyl diaphragm,
Page 3
Advanced
design features
continue to set industry standards
Stainless steel air valve is welded in position rather than mechanically
threaded to prevent loss of air pressure and to minimize stress on the well’s pump system. It also carries a tamper-evident warning label.
Deep-drawn steel domes offer twice the strength of rolled steel while
minimizing weight.
Unique positive hoop ring seal secures diaphragm and liner for added
strength and reliability.
Heavy duty butyl diaphragm features seamless construction for uniform
strength and flexibility. It conforms exactly to the shell configuration without stretching, creasing, or forming bubbles or corners that could trap water or sediment. Butyl is the best known elastomer to prevent air loss.
Heavy duty butyl diaphragm is extremely resistant to bacterial growth and
meets FDA requirements for potable water supply.
Virgin polypropylene liner provides a 100% corrosion resistant, non-metallic
rigid water reservoir that is listed by NSF International Standard 61.
Stainless-steel system connection withstands aggressive water.
Exclusive welding process eliminates interior rough spots and sharp edges
which prevent damage to the diaphragm and liner.
Dome
Hoop
Diaphragm
Liner
Each finished tank is pressure tested for safety
Each finished tank is pre-pressurized to the most common pump cut-in
pressure.
Exterior appliance-like finish looks attractive while protecting the tank from
the elements.
.
Dome
Stainless-steel System Connection
Stand
Page 4
esp(Effective System Protection):
maximum system output with
minimal pump starts
The ESP sizing procedure covers modern residential water-use habits, increased off-peak demands and the general increase in water use that have occurred over the past twenty-five years.
ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping pump starts to a minimum.
Choose the amount of protection you need.
ESP I: Tank selection is based on approximately one minute minimum pump running time.
This is recommended for pumps up to 3/4 H.P.
ESP II: Tank selection is based on approximately two minute minimum pump running time. This is recommended for 3/4 H.P. or larger pumps.
ESP Sizing Table
OPERATING PRESSURE - PSIG
PUMP DISCHARGE ESP I ESP II RATE GPM (Approx.) 20/40 30/50 40/60 20/40 30/50 40/60
5 WX-202 WX-202 WX-202 WX-202XL WX-205 WX-205
7 WX-202 WX-202 WX-202XL WX-205 WX-250 WX-251
10 WX-202XL WX-205 WX-205 WX-251 WX-251 WX-255
12 WX-205 WX-250 WX-250 WX-251 WX-255 WX-255
15 WX-250 WX-250 WX-251 WX-255 WX-302 WX-350
20 WX-251 WX-251 WX-255 WX-350 WX-350 (2) WX-255
25
30 WX-255 WX-302 WX-350 (2) WX-255 (2) WX-302 (2) WX-350
35
40
WX-251
WX-302
WX-350 WX-350 (2) WX-255 (2) WX-350 (2) WX-350 (3) WX-302
WX-255
WX-350 WX-350 (2) WX-302 (2) WX-350 (2) WX-350
WX-302
(2) WX-251
(2) WX-255 (2) WX-302
Page 5
WELL-X-TROL Professional
tank operation
time-tested design
WELL-X-TROL Professional has a sealed in air chamber that is pre-pressurized before it leaves our factory. Air and water do not mix.
1
When the pump starts, water enters the WELL-X-TROL Professional. Only usable
2
water is stored.
When the pressure in the chamber
ts ar
e assur
essure, the pump
3
, minimum
er
at
ed.
hes cut-out pr
eac
r stops. The WELL-X-TROL Professional is filled.
When water is demanded, pressure in the air chamber forces water into t
he system. Since WELL-X-TROL Professional consistently delivers the maximum usable w
ar
t
p s
pum
4
Page 6
WELL-X-TROL Professional
residential
models
In-Line Models
Dimensions Total Max. System Drawdown Shipping
Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
(ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
& WX-102 is 20 PSIG and Sys. Conn. is 3/4" NPTM.
Dimensions Total Max. System Drawdown Shipping
22
26
essure for WX-205 thru WX-350 is 38 PSIG and Sys. Conn. is 1 1/4" NPTF.
ge Pr
56 3/8 81.0 0.41 32.6 27.5 23.8 103
47 1/4 86.0 0.54 34.6 29.2 25.3 123
Ultra TUF-KOTETMexcept WX-104-S, WX-201, and WX-252.
Stand Models
Model
No.
WX-101 8 12 5/8 2.0 0.45 .8 .7 .6 5 (0.6)
WX-102 11 15 4.4 0.55 1.8 1.5 1.3 9 (1.2)
WX-103 11 22 1/4 7.6 0.42 3.1 2.6 2.2 15 (1.8)
WX-104 15 3/8 17 3/4 10.3 1.00 4.1 3.5 3.0 20 (2.6)
WX-200 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22 (3.3)
echarge Pressure for WX-101
Pr Precharge Pressure for WX-103 is 30 PSIG and Sys. Conn. is 3/4" NPTM.
echarge Pressure for WX-104 and WX-200 is 30 PSIG and Sys. Conn. is 1" NPTM.
Pr Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F. WX-101 and WX-102 models available with Ultra TUF-KOTE
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-104-S 15 3/8 19 1/4 10.3 1.00 4.1 3.5 3.0 23
WX-201 15 3/8 23 7/8 14.0 0.81 5.6 4.8 4.1 25
WX-202 15 3/8 31 5/8 20.0 0.57 8.0 6.8 5.9 33
WX-202XL 15 3/8 38 1/4 26.0 0.44 10.5 8.8 7.6 36
WX-203 15 3/8 46 1/2 32.0 0.35 —- 10.9 9.4 43
WX-205 22 29 5/8 34.0 1.00 13.7 11.6 10.0 61
WX-250 22 36 44.0 0.77 17.7 15.0 12.9 69
WX-251 22 46 3/4 62.0 0.55 24.9 21.1 18.2 92
WX-255
WX-252 22 62 1/4 86.0 0.39 34.6 29.2 25.3 114
WX-302
WX-350 26 61 7/8 119.0 0.39 47.8 40.5 35 166
echarge Pressure for WX-104-S thru WX-203 is 30 PSIG and Sys. Conn. is 1" NPTF.
Pr
echar
Pr Maximum Working Temperature is 200° F. Maximum Working Pressure for all models except WX-252 is 125 PSIG. Maximum Working Pressure for WX-252 is100 PSIG. All models available with All models except, WX-104S, WX-201, WX-252 are available with Pro-Access.
TM
exterior coating option.
Underground Models
Model
No.
WX-200-UG 15 3/8 22 14.0 0.81 5.6 4.8 4.1 22
WX-202-UG 15 3/8 30 20.0 0.57 8.0 6.8 5.9 30 (4.9)
WX-250-UG 22 33 3/8 44.0 0.77 17.7 15.0 13.0 60 (9.8)
WX-251-UG
Precharge Pressure for WX-202-UG is 30 PSIG and Sys. Conn. is 1" NPTF Coupling. Precharge Pressure for WX-205-UG and WX-251-UG is 38 PSIG and Sys. Conn. is 1 1/4" NPTF Coupling. Maximum Working Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
Diameter
(ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
22
Dimensions Total Max. System Drawdown Shipping
Height
44 1/8
olume
V
62.0
Accept.
0.55
20/40
24.9
40/60 Wt. (Vol.)
30/50
15.3 83 (13.9)
21.1
Page 7
WELL-X-TROL Professional
specialty residential
models
Pump Stand Models
Dimensions
Model
No. (ins) (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-105-PS 11 10 9/16 18 1/4 5.3 0.80 2.1 1.8 1.6 13
WX-200-PS 16 15 3/8 20 7/8 14.0 0.81 5.6 4.8 4.1 29
echarge Pressure is 30 PSIG and Sys. Conn. is 3/4" NPTM Fitting for 103-PS and 105-PS; and 1" NPTF Coupling for 200-PS.
Pr Maximum W
Height Width Length Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
orking Pressure is 125 PSIG and Maximum Working Temperature is 200° F.
Offset Connector Models
Model Diameter Height Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft)
WX-202-OC 15 3/8 29 20.0 .57 8.0 6.8 5.9 32 (5.0)
1” Barb Connection. 30 PSIG Precharge Pressure. 100 PSI Maximum Working Pressure. 200° (F) Maximum Working Temperature
Dimensions Total Max. System Drawdown Shipping
Total Max. System Drawdown Shipping
Space Saver Model
Model Height Width Length Volume Accept. 20/40 30/50 40/60 Wt. (Vol.)
No.
WX-202-H 28 5/8 15 3/8 15 1/4 20.0 0.57 8.0 6.8 5.9 33 (4.9)
Precharge Pressure is 30 PSIG. System connection is 1" NPTF (straight coupling connection). Maximum W
orking Pressure is 125 PSIG. Maximum Working Temperature is 200° F.
Dimensions Total Max. System Drawdown Shipping
(gals) Factor (gals) (gals) (gals) lbs (cu ft)
(ins)
(ins)
(ins)
Specialty Options
A new improved paint finish available only on WELL-X-TROL tanks. This new paint has been re-formulated for outdoor applications where acids, salts and moisture can harm regular paint. It is crack proof and impermeable to moisture.
PRO Access Stainless Steel System Connection piped thr on most WELL-X-TROL models. Indicate PRO Access when or
ough the stand is available
dering.
Page 8
®
AMTROL has
®
innovative ways
to help you grow your business
Water Treatment Technologies
Hydrogen Sulfide Removal System Arsenic Removal System
Boiler Expansion Tanks Water Heater Expansion Tanks Indirect-Fired Water Heaters
Ask for Quality. Ask for AMTROL®.
www.amtrol.com
Part# 9015-516 MC# 4380 (7/04) © 2004 AMTROL Inc. WELL-X-TROL is a registered trademark of AMTROL Inc.
Iron Removal System Water Softening and Filtration
Hydronic Technologies
Corporate Headquarters
1400 Division Road
arwick, RI 02893
est W
W
Telephone: 401-884-6300
Fax: 401-884-5276
AMTROL Canada, Ltd.
275 Shoemaker Street
Kitchener
Telephone: 519-748-1138
Fax: 519-748-4231
, Ontario N2E 3B3