Amtrol WELL-X1, WELL-X-TROL User Manual

INSTALLATION, OPERATION
& MAINTENANCE
INSTRUCTIONS
9013-0001 (3/08)
WELL-X-TROL® WELL-X1
INSTALLER: LEAVE THIS MANUAL WITH THE OWNER
IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.
READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL. FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
This is the safety alert symbol. It is used to alert you to personal injury hazards. Obey all safety instructions that follow this symbol to reduce the risk of possible injury or death as well as property damage.
West Warwick, Rhode Island 02893
1. TABLE OF CONTENTS
GENERAL SAFETY INFORMATION ........................................................... 2
COMPONENTS ...........................................................................................3
INSTALLATION AND SIZING CONSIDERATIONS ..................................... 4
INSTALLATION CONSIDERATIONS...........................................................5
PLUMBING .................................................................................................. 6
WIRING ........................................................................................................ 8
STARTUP & ADJUSTMENT ........................................................................ 9
PUMP PROTECTION & DIAGNOSTICS ...................................................13
TROUBLESHOOTING ............................................................................... 14
REPLACEMENT PARTS ........................................................................... 15
This Product, like most Products under pressure, may over time corrode. weaken and burst or explode, causing serious or fatal injury, leaking or flooding and/or property damage. To minimize risk, a licensed professional must install and periodically inspect and service the Product. A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage. Do not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure.
Chlorine & Aggressive Water: The water quality can significantly influence the life of this Product. You should test for corrosive elements, acidity, total solids and other relevant contaminants, including chlorine and treat your water appropriately to insure satisfactory performance and prevent premature failure.
NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
ELECTROCUTION AND EXPLOSION HAZARD! Before work is performed on the Product, turn off the power to the Product and release all pressure in the system.
As in all plumbing products and water storage vessels, bacteria can grow in this Product, especially during times of non-use. Consult your local plumbing professional regarding any steps you may wish to take to safely disinfect your home’s plumbing system.
DANGER! EXPLOSION HAZARD, WHEN THE WELL-X1™ HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY DUE TO A REQUIRED CHANGE IN THE PRESSURE SWITCH SETTING, FAILURE TO FOLLOW INSTRUCTION MANUAL CAN CAUSE A RUPTURE OR EXPLOSION, POSSIBLY CAUSING SERIOUS OR FATAL INJURY, AND/OR PROPERTY
DAMAGE. • DO NOT ADJUST THE PRE-CHARGE PRESSURE
IF THERE HAS BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-CHARGE PRESSURE COMPARED TO ITS INITIAL SETTING. THIS IS BECAUSE REDUCTION IN
PUMP CYCLE TIME CAN RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN TURN CAN MEAN THERE MAY BE INTERNAL CORROSION AND ANY RE-PRESSURIZATION OR ADDITIONAL PRESSURE COULD RESULT IN RUPTURE OR EXPLOSION, AND/OR PROPERTY DAMAGE.
RELIEF VALVE REQUIRED. A relief valve has been installed which is set to open at excessive pressures (100 psig or more). This will protect the Well-X1™ and other system components should the pressure switch malfunction and fail to shut the pump off. The relief valve is installed at the connection of the Well-X1™ to the system piping.
Before attempting any service and disassembly, shut off power to the pump. Ensure power is disconnected prior to removing motor. Ensure power is disconnected before cleaning is attempted.
This control is capable of running pumps to pressures that may exceed the limitations of system components. Never set the operation pressure higher than that of the safe system capacity.
This control can be adjusted to a narrow pressure differential. This can cause the pump to cycle rapidly with an improperly sized tank, leading to pump damage. This may require a larger pressure tank than normally used.
CALIFORNIA PROPOSITION 65 WARNING: This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/Contractor ­California law requires that this notice be given to consumer/ end user of this product.) For more information: www.
amtrol.com/prop65/htm
Every Well-X1™ is air tested to 125 psig,
the maximum working pressure for the Well-X1™.
The pump controller is not a disconnect. The pump may be activated at any time. The electrical system must be considered energized at all times unless the circuit breaker is open. The disconnect for the controller must break all incoming power lines. As with a mechanical pressure switch, when installed with three wire 230 vac pumps or any 3-phase pump, a standard pump motor starter or a relay must be used.
2
2. GENERAL SAFETY INFORMATION
3
3. COMPONENTS
The Well-X1™ combines all the standard well tank components in a single, easy to install package. The pressure tank, control and tank fittings are factory-installed. After removing from the carton, inspect the Well-X1™ for damage and ensure all components are present.
CONDUIT HOLES
PUMP & POWER WIRES
AIR CHARGING VALVE
RELIEF VALVE
MOUNTING KNOB
WATER CONNECTIONS(2)
CONTROL
PRESSURE
TANK
DRAIN
TANK TUBING
PRESSURE SENSOR TUBING
MOUNTING BRACKET
COVER
4
4. INSTALLATION AND SIZING CONSIDERATIONS
The Well-X1™ functions like a traditional pressure switch by cycling the pump on and off. The factory pressure settings are 40 psi cut-in and 60 psi cut-out. The controller allows these settings to be adjusted to best suit the application. The Well-X1™ can operate in two primary modes:
WELL-X1™ SELECTION FOR CONSTANT PRESSURE
Control Setting (cut-in/cut-out) (psi)
40/50 50/60 60/70 70/80
PUMP GPM
4
- WX1-203 WX1-203 WX1-203
5
WX1-203 WX1-203 WX1-250 WX1-250
7
WX1-250 WX1-250 WX1-251 WX1-251
10
WX1-251 WX1-251 WX1-302 WX1-302
12
WX1-251 WX1-302 WX1-302 WX1-302
15
WX1-302 WX1-302 - -
WELL-X1™ SELECTION FOR STANDARD SYSTEMS
Control Setting (cut-in/cut-out) (psi)
30/50 40/60 50/70 60/80
PUMP GPM
4
WX1-202 WX1-202 WX1-202 WX1-202
5
WX1-202 WX1-202 WX1-202 WX1-203
7
WX1-203 WX1-203 WX1-203 WX1-203
10
WX1-203 WX1-250 WX1-250 WX1-251
12
WX1-250 WX1-250 WX1-251 WX1-251
15
WX1-251 WX1-251 WX1-302 WX1-302
18
WX1-251 WX1-302 WX1-302 WX1-302
20
WX1-302 WX1-302 WX1-302 -
A. STANDARD OPERATION
Using a standard 20 psi differential, the Well-X1™ can be sized according to the chart below. In this application, the sizing and performance will be similar to a traditional pressure tank and mechanical switch combination.
B. CONSTANT PRESSURE MODE
The Well-X1™ control allows a narrow differential to provide consistent water pressure. The factory 20 psi differential can be reduced so the cut-in and cut-out pressures are within 10 psi. When installed as a constant pressure system, the chart below should be used to ensure the tank volume is sufficient to provide adequate cycle protection.
The maximum working pressure of the Well-X1™ is 125 psig. Do not
exceed the maximum working pressure.
5
5. INSTALLATION CONSIDERATIONS
LOCATION
The Well-X1™ is designed for indoor and outdoor installations. The NEMA 3R enclosure can be installed in direct weather. If installed outdoors, be sure the following conditions are met:
• Do not install where ambient temperatures can drop below freezing
or exceed 120° F.
• Ensure a Tuf Kote™ model is selected (Example: WX1-302TK)
for outdoor installations. This proprietary coating is specifically designed to withstand outdoor applications.
• Use water-tight: wiring conduit, wire nuts and conduit connections
as dictated by applicable codes and ordinances.
• Protect the piping from mechanical damage.
• Install the relief valve blow down tube where venting water will not
cause personal injury or damage the surrounding property.
• Drip Pan and Drain: To avoid leaking and/or property damage,
install with a drip pan connected to an adequate working drain kept clear at all times.
ORIENTATION
Ensure the installation meets all applicable local codes and is installed by a qualified professional. Additionally, the following should be noted.
• This unit is designed for vertical installation above ground only.
Do not install horizontally or directly bury the unit. The Well­X1™ may be installed below grade in a well pit or other suitable enclosure. Do not locate in an area where leaking or flooding could cause property damage to surrounding areas.
• Check codes to determine if there are any height requirements
pertaining to the Well-X1™. Particularly, ensure the bottom drain meets these requirements. If restrictions are imposed on the proximity of drain connections to the floor, the unit may be elevated on blocks or the bottom drain tube can be removed and plugged, after which a sampling tap may be installed in the water lines near the top of the Well-X1™.