Amtrol SPT-28, SPT-14, SPT-18, SPT-21, SPT-35 Installation & Operation Instructions

...
INSTALLATION & OPERATION
INSTRUCTIONS
West Warwick, Rhode Island 02893
SURGE-TROL
SURGE-TROL
Surge Arrestor SPT-7 thru SPT-70
For Models:
SPT-7
SPT-11
SPT-14
SPT-18
SPT-35
SPT-42
SPT-50
SPT-56
SPT-21
SPT-70
SPT-28
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL. FAILURE
TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
* All SURGE-TROL™ Series models come with a 1 year warranty. See back page for warranty information.
PN: 9017-140 (05/10)
MARK OF THE ORIGINATOR
TYPICAL INSTALLATION
PUMP
CHECK VALVE TO SYSTEM
SURGE-TROL
IMPORTANT GENERAL SAFETY INFORMATION
ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS
EXPLOSION OR RUPTURE HAZARD A
relief valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the Product Manual, whichever is less. Do not expose Product to freezing temperatures or temperatures in excess of 240° F. Do not exceed maximum allowable working pressure 275 psig. Do not adjust the pre­charge or re-pressure this Product except for any adjustments required at the time of initial installation, especially if Product is corroded, damaged or with diminished integrity. Adjustments to pre-charge must be done at ambient temperature only. Failure to properly size the Product or follow these instructions may result in excessive strain on the system leading to Product failure, serious or fatal personal injury, leakage and/or property damage.
This Product, like most Products under
pressure, may over time corrode. weaken and burst or explode, causing serious or fatal injury, leaking or flooding and/or property damage. To minimize risk, a licensed professional must install and periodically inspect and service the Product. A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage. Do not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure.
Chlorine & Aggressive Water. The water
quality can significantly influence the life of this product. You should test for corrosive elements, acidity, total
INSTALLATION AND OPERATION INSTRUCTIONS
solids and other relevant contaminants, including chlorine and treat your water appropriately to insure satisfactory performance and prevent premature failure. Note: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage present. If the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional. Current copies of the product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
GENERAL SAFETY INFORMATION ­ADDITIONAL SPECIFIC SAFETY ALERTS
APPEAR IN THE FOLLOWING INSTRUCTIONS.
CALIFORNIA PROPOSITION 65 WARNING:
This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/Contractor ­California law requires that this notice be given to consumer/end user of this product.) For more information: www.amtrol.com/ prop65/htm.
DO NOT USE OXYGEN - EXPLOSIVE!
Protect against freezing temperatures. Never pre-charge below 50% of maximum system pressure.
Diagram 1
Pre-Installation
1. Visually inspect the Surge-Trol for any damage. If damage exists return product for replacement.
2. Remove air cap.
3. For applications with pump start-up creating water hammer adjust the factory pre-charge setting to 15% below static pressure.
4. For applications with surge issues created by pump shut down adjust the factory pre-charge setting to 50% below static pressure.
5. For applications with quick closing valves, please consult manufacturer for tank location and pre-charge settings. (401) 535-1216.
6. Replace and tighten cap on air valve.
If adjusting the pre-charge pressure
higher than 55 PSIG the unit must be tied to the system immediately. Failure to do so could damage the bladder and void all warranties.
Installation
1. The Surge-Trol should be installed as close to the
offending xture as possible in applications where there are issues with a quick closing valve.
2. The Surge-Trol should be installed as close to the
pump as possible in surge applications.
3. Once the Surge-Trol is installed and the pre-charge
adjusted properly, check for any leakage. Make repairs if necessary
Maintenance
1. A qualied professional should check the complete
system, including the Surge-Trol, yearly and more frequently as the system ages.
Operation
1. The Surge-Trol is designed to provide surge protection
as well as provide a cushion to prevent water hammer depending on its application.
2. Water temperature is not to exceed 240°F. or fall
below 35°F.
3. The factory pre-charge setting is 25 PSIG and should
only be adjusted at the time of the installation.
4. System velocity shall not exceed 22 fps.