![](/html/c7/c7b0/c7b0dca6b1e6ce1fee3da5f1ea535fab5242fec643db00d92a6e627e12ce542b/bg1.png)
DIATROL
®
SHOCK SUPPRESSOR
INSTALLATION & OPERATION INSTRUCTIONS
Models D-7 through D-70
NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal
injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current
copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER
HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL
INJURY AS WELL AS PROPERTY DAMAGE.
READ CAREFULLY THE PRODUCT
INSTALLATION & OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE
MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR
PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.
THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED
PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES,
FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE
This Product, like most Products under pressure,
may over time corrode, weaken and burst or
explode, causing serious or fatal injury, leaking or flooding and/or property
damage. To minimize risk, a licensed professional must install and
periodically inspect and service the Product. A drip pan connected to an
adequate drain must be installed if leaking or flooding could cause
property damage. Do not locate in an area where leaking could cause
property damage to the area adjacent to the appliance or to lower floors
of the structure.
Chlorine & Aggressive Water. The water quality can significantly influence the life of this product. You should test for corrosive elements,
acidity, total solids and other relevant contaminants, including chlorine
and treat your water appropriately to insure satisfactory performance and
prevent premature failure.
EXPLOSION OR RUPTURE HAZARD. A relief
valve must be installed to prevent pressure in
excess of local code requirement or maximum working pressure
designated in the Product Manual, whichever is less. Do not expose
product to freezing temperatures or temperatures in excess of 240°F. Do
not adjust the pre-charge or re-charge this Product except during
installation or regular inspection. Replace the Product and do not adjust
the pre-charge if corroded, damaged or with diminished integrity.
Adjustments to pre-charge must be done at ambient temperature only.
Failure to properly size the product or follow these instructions may result
in excessive strain on the system and may lead to product failure, serious
or fatal personal injury, leakage, and/or property damage.
CALIFORNIA PROPOSITION 65 WARNING! This product contains a
chemical known by the State of California to cause cancer and to cause
birth defects or other reproductive harm. (California Installer/Contractor
- California law requires that this notice be given to consumer/end user
of this product.) For more information: www.amtrol.com/prop65.html
![](/html/c7/c7b0/c7b0dca6b1e6ce1fee3da5f1ea535fab5242fec643db00d92a6e627e12ce542b/bg2.png)
PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY
IMPORTANT GENERAL SAFETY INFORMATION -
ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.
Pre-Installation
1. Visually inspect the Diatrol® for any damage. If damage exists
return product for replacement.
2. Adjust pre-charge to equal 10% below system pressure.
3. Replace and tighten plastic cap on air fitting.
Installation
1. The Diatrol should be installed as close to the offending fixture
or source of water hammer as possible.
2. Once the Diatrol is installed, check the CWS line for any
leakage. Make repairs if necessary.
Maintenance
1. Aqualied professional should check the complete system,
including the Diatrol, yearly and more frequently as the system
ages.
Operation
1. The Diatrol is installed in the line as close to the offending fixture
as possible. Its sealed-in air pre-charge prevents water from
entering it until the system pressure exceeds the pre-charge
pressure. A properly pressurized tank will only allow a small
volume to enter its bladder under normal flow conditions.
2. When a sudden valve closure occurs, the resulting pressure
surge travels back from the valve to the bladder-type shock
suppressor forcing the bladder to expand into the air cushion.
3. The shock is absorbed by the compressing of the air. After
absorption of the shock, the system water pressure and the air
chamber pressure equalize at the static pressure level.
4. Water temperature is not to exceed 240°F or fall below 35°F.
Warranty
Diatrol models: One (1) Year Limited Warranty
Visit www.amtrol.com for complete warranty details.
1400 Division Road, West Warwick, RI USA 02893
T: 800.426.8765 F: 800.293.1519
© 2014 AMTROL Inc. Part #: 9017-130 (01/14)