Amprobe TMA-21HW, RLD-1 Catalog Page

TMA-21HW
TMA-21HW Hot Wire Anemometer
Hot wire anemometer technology eliminates bearings and rotating parts to make these meters durable and measurements stable and accurate. It’s the simple, safe way to monitor indoor air quality and measure air flow and temperature in residential, commercial and industrial air conditioning systems.
• 4' (1.2m) telescopic wand - no ladder needed for most commercial applications
• Measures air flow volume in CFM, CMM
• Instant average, 2/3 Vmax flow measurements
• Velocity m/s, ft/min, knots, km/hr, mph
• Relative humidity and temperature measurement
FEATURE TMA-21HW BEST ACCURACY
0.10 m/s
0.2 km/hr
Air Flow
Air Flow Volume
Temperature
Relative Humidity 0.0
Data-logging via USB
Wet Bulb / Dew Point
INCLUDED ACCESSORIES: Batteries (installed), hard carrying case, user manual, USB cable and PC software
10 ft/min
0.10 knots
0.12 MPH
0.000 CFM
0.000 CMM
- 4°F
(-20°C
• Data hold, min/max with time stamp
• Data memory and real-time function (99 sets)
• 512KB auto data-logging capacity
• USB interface
• Wet bulb and dew point
• Large backlight LCD display shows five parameters
^ 30.00 m/s ^ 110.0 km/hr ^ 6000 ft/min
^ 59.0 knots
^ 68.00 MPH
^ 999900 CFM ^ 999900 CMM
^ 140°F
^ 60°C)
^ 100% +/- 3%
+/- 3% of rdg +/-1% FS
+/- 3%
+/- 0.9°F (+/- 0.5°C)
RLD-1
Recommended Accessories
RLD-1 SENSOR Replacement Sensor (Replacement part)
TOP R ATE D
“Best tool for the job!”
In over 25 years of business, I've seen units with suspected refrigerant leaks but were too small to find. With the Amprobe RLD-1 refrigerant leak detector I can take the guess work out of finding and repairing a refrigerant leak. I recommend that if you are in the HVAC business this is a must have for every tool bag!”
- RLD-1 Customer reviews
RLD-1 Refrigerant Leak Detector
Troubleshoot air conditioning systems quickly and accurately with the RLD-1. State-of-the-art technology makes it easy to precisely pinpoint a wide variety of halogenated refrigerant leaks.
• Detects R-134a, R-404a, R-407c, R-410a, R-22, Freon and other refrigerants
• Sensitive gas sensor and advanced digital signal processing for high accuracy
• Built-in suction pump for precise sensor response
• Tri-color LED display and audio clearly indicate leaks
FEATURE RLD-1
Detectable Gases R-134a, R-404a, R-407c, R-410a, R-22, Freon
R-22, 134a Sensitivity H - 3g/year, M - 15g/year, L - 30g/year
R-4 04a, 407c, 410a Sensitivity H - 4g/year, M - 20g/year, L - 40g/year
Alarm Method Buzzer, Tricolor LED bar Indicator
Power Usage 2 C size (3V DC) Alkaline Batteries
Snake Tube Length 15.5” (40 cm)
INCLUDED ACCESSORIES: Batteries (installed), user manual, carrying case, leak check bottle, AC adapter
• High-Medium-Low (H/M/L) leak sensitivity selector
• Automatic zero and background compensation
• Low battery indication
• Ambient concentration reset
46
Loading...