Amprobe TIC 300 PRO Quick Start Guide

Meet The New Standard In Non-Contact, High Voltage Detection
The Amprobe TIC 300 PRO with VolTect
SELF-TEST
30 V to 1,500 V ac
High range
1,500 V to 122k V ac
LED lights
Shotgun adapter
for hot stick attachment
TIC 300 PRO with VolTect
TIC 300 PRO with VolTect™ Quick Start Guide
On/Off Button:
When the TIC 300 PRO is activated, the blue LED’s and audible alert will pulse at a slow rate, approxi­mately twice per second.
SELF-TEST Button: The TEST button should be used to ensure tool is operational. The TEST function will cause the blue LEDs and audible alert to pulse at a continuous rate on either LOW or HIGH range setting.
LOW Range Setting
1. Push ON/OFF button to turn the unit ON.
2. The unit will default to the high voltage setting when powered­up. A twice per second beep will be heard, and the blue LEDs will flash at the same rate.
3. Push the LOW range button, and the unit is ready for low voltage detection.
Sensitivity
Low Voltage
Voltage
(Phase to neutral with 890K Ohm load)
30 V 1.5”
75 V 6.5”
100 V 8.5”
120 V 10”
220 V 1’1”
500 V 1’7”
1000 V 2’10”
For complete information on the TIC 300 PRO, visit www.Amprobe.com/TIC300PRO
Detection Range
(From the TIP of probe to the target line)
Average
4. Place the probe tip of the TIC 300 PRO with VolTect™ near, but not touching the low (<1000 V) voltage source. See bottom table for range details.
5. If voltage is present, the blue LEDs and audible alert will pulse at an increased rate.
HIGH Range Setting
(> 1500 V and <122 kV) (TIC 410A Hot Stick must be used)
1. Push the HIGH range setting button.
2. Approach the probe tip near, but not touching the high volt­age conductor. See bottom table for details.
3. If voltage is present, the blue LEDs and audible alert will pulse at an increased rate.
High Voltage
Voltage
(Open Phase with no load)
1.5 kV 0.5”
2.0 kV 1”
4.0 kV 2”
10.0 kV 8”
15.0 kV 1’2”
20.0 kV 1’8”
25.0 kV 2’2”
Detection Range (From the TIP of probe to the target line)