Data Sheet
PRM-4
Phase Sequence and Motor
Rotation Tester
Identifies 3-phase sequence and open phase check
■
Motor shaft rotation indication protected by CAT III
■
circuitry
CAT III 600V rated for both testing segments
■
Meets current EN61010 safety requirements, CSA,
■
EN61557-7
Supplied with three CAT III rated color coded large
■
alligator clips and test leads
Zippered carrying case for portability
■
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
“No Hassle” warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
Included Accessories
Test Leads (red, green, and blue) with
alligator clips (TL-PRM-4), Soft Vinyl
Case, Users Manual, 9 V Battery
Optional Accessories
L-PRM-4 Replacement Test Leads
T
FP900 Replacement Fuses
Amprobe® Test Tools
www.Amprobe.com
PRM-4 Phase Sequence and Motor Rotation Tester
Data Sheet
General Specifications
Operating Environment 0 °C to 40 °C at < 80 % R.H.
Power Single standard 9 V battery
attery life Approximately 200 hours typical with carbon-zinc battery
B
L
ow battery indication The BATT LED does not come ON when TEST button is pressed
imensions (H x W x D) 153 mm x 72 mm x 35 mm (6.02 x 2.83 x 1.37 in)
D
Weight Approximately 218 g (7 oz) including battery.
Environment Indoor use
Altitude 2000 m (6561 ft.)
Overload protection 600 V ac
A
gency Approvals CE, cCSAus
afety Conforms to EN61010-1:2001
S
EMC Conforms to EN61326-1. This product complies with requirements of the following European Commu-
NEDA 1604
JIS 006P
IEC 6F22
CAT III 600V, Pollution degree 2, Class 2
CSA 22.2 -1010-1
EN61557-7
nity Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23 / EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to
unwanted signals that may be present within the measurement circuit. Users should exercise care and
take appropriate precautions to avoid misleading results when making measurements in the presence
of electronic interference.
Electrical Specifications
Function Range
Phase Sequence
Input Voltage 3 phase to phase inputs 100 V ac to 600 V ac max.
Frequency 45 to 70 Hz
O
perating Time 10 minutes ON maximum at 600 V ac
10 minutes OFF minimum at 600 V ac
3-Phase load Approx. 7 mA per phase of ac power source
Motor Rotation
Operating Time 10 minutes ON maximum
10 minutes OFF minimum.
Motor Rotation tester field 14 mA of 9 V battery
Amprobe® Test Tools
website: www.Amprobe.com
email: info@amprobe.com
Everett, WA 98203
Tel: 877-AMPROBE
Amprobe® Test Tools
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
©2008 Amprobe Test Tools. All rights re served.
2/2008 33 03533 Rev A