Amprobe PM-60 User Manual

Page 1
PM-60
Pocket Meter
Users Manual
• Mode d’emploi
• Bedienungshandbuch
• Manual d’Uso
• Manual de uso
Page 2
Page 3
PM-60
Users Manual
©2009 Amprobe Test Tools. All rights reserved. Printed in China
English
Page 4
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Repair
All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe® Test Tools distributor for an exchange for the same or like product. Please check the “Where to Buy” section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe® Test Tools Service Center (see next page for address).
Page 5
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 888-993-5853 Tel: 905-890-7600 Fax: 425-446-6390 Fax: 905-890-6866
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test Tools distributor for a nominal charge. Please check the “Where to Buy” section on www.amprobe.com for a list of distributors near you. Amprobe® Test Tools Europe In den Engematten 14 79286 Glottertal, Germany tel: +49 (0) 7684 8009 - 0 *(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
Page 6
PM-60 Pocket Meter
1
2
3
4
5
1). LCD Display
2). Hold function key
3). Function selection key
4). Range key
5). Function Selector
6). Test Leads
6
Page 7
CONTENTS
SYMBOLS ..........................................................................2
UNPACKING AND INSPECTION ........................................3
INTRODUCTION ................................................................ 3
OPERATION ....................................................................... 4
SPECIFICATION .................................................................8
MAINTENACE .................................................................... 13
TROUBLE SHOOTING ........................................................ 13
Battery Replacement ...................................................14
1
Page 8
SYMBOLS
Warning! Dangerous Voltage (Risk of electric
shock).
Caution ! Refer to the user’s manual before
using this Meter.
Double Insulation or Reinforced insulation
Alternating Current (AC).
Direct Current (DC).
Low battery indicator
Ground (maximum permitted voltage
between terminal and ground).
Please remove all the test leads before preforming maintenance, cleaning, battery
replacement, fuse replacement, etc
Complies with European Directives
Conforms to relevant Australian standards
Do not dispose of this pruduct as unsorted municipal waste.
Contact a qualified recycler for disposal
Warning!
To ensure safe operation and service of the Meter, follow
these instructions.
Failure to observe warnings can result in severe injury or death.
• Do not operate this meter in explosive gas
(material), combustible gas (material) steam or filled with dust.
• When using test leads or probes, keep your ngers
behind
the finger guards.
2
Page 9
• Use the Meter only as specied in this manual or
the protection by the Meter might be impaired.
• Always use proper terminals, switch position and
range for measurements.
• Do not apply more than the rated voltage, as
marked on Meter, between terminals or between any terminal and earth ground.
• To avoid false readings that can lead to electric
shock and injury, replace battery as soon as low battery indicator appears.
• Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance, continuity, diodes, or capacitance.
• To reduce the risk of re or electric shock; do not
expose this product to rain or moisture.
UNPACKING AND INSPECTION
Your shipping carton should include:
1 PM-60 Meter
2 Battery (GPA76P, 1.5V)
1 User’s Manual
If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange.
INTRODUCTION
This meter PM-60 can be measured voltage, resistance, frequency, capacitance, diode, current (uA) and
continuity; It is an electronic measuring instrument that
combines several measurement functions in one unit. PM-60 multimeter is portable hand-held devices useful for basic fault finding and field service work. It can be used to troubleshoot electrical problems.
3
Page 10
OPERATION
Auto Power Off
Display Hold
The internal sounder will operate continuously with LCD display flashing in two situations in the Data Hold mode:
1. The Meter measure a signal different from the LCD reading.
2. The measured signal is the same unit as the LCD reading and is larger 50 counts than the LCD reading.
4
Page 11
Auto Range / Manual Range
Selecting Function
5
Page 12
Resistor / Capacitor / Continuity / Diode
• For better measurement accuracy of small value
capacitance, subtract the residual capacitance of the Meter and leads from measurement.
• Under diode mode, LCD displays “bad” when
measuring a diode conducted at forward and reverse bias.
• LCD displays capacitance mode when no
measurement at Auto-sense mode.
• Under Auto-sense mode, do not measure a
broken component, a unknown component, or a component with mixed electrical characteristic, such as measuring a resistor and a capacitor in parallel. The meter may display incorrectly.
6
Page 13
AC V / DC / Hz / Duty
CAUTION
When connecting the test leads to the circuit or device,
connect the black lead rst, then connect the red lead ;
when removing the test leads, remove the red lead first, then remove the black lead.
Volt Sense
• The number of dashes displaying on the LCD
indicates the electric field intensity.
7
Page 14
• If no indication, voltage could still be present.
• Using only red test probe to work as mains voltage
indicator.
AC A / DC A
SPECIFICATION
General Specications
LCD display digits: 4000 counts digit large scale LCD
readout.
Measuring rate: 3 times / sec. Polarity Indication:Automatic, positive implied, Overrange display: “OL” or “-OL” Unit symbol
indication. Automatic power off time: Approximately 20 minutes after power on.
Low battery indicator: Display on LCD Power requirement: 1.5V x 2 batteries. Battery life: 50 hours (GPA76P)
Environmental Conditions
Indoor Use Calibration: One year calibration cycle Operating temperature: 0°C/32°F ~ 30°C/86°F (80% RH)
30°C /86°F ~ 40°C/104°F (75% RH) 40°C/ 104°F ~ 50°C/122°F (45%RH)
8
Page 15
Storage temperature: -20 to +60°C (-4°F to 140°F), 0 to 80% RH (batteries not fitted). Temperature coefcient: Add 0.2 x (Specified accuracy) / °C, < 18°C (64.4°F), > 28°C (82.4°F). Shock vibration: Sinusoidal vibration per MIL-T-28800E (5 ~ 55 Hz, 3g/0.007lb maximum). Drop Protection: 4 feet drop to hardwood on concrete floor. Overvoltage category: IEC 61010-1 300V CAT. ., 600V CAT. II.
CAT Application eld
The circuits are not connected to mains.
The circuits are directly connected to Low-
voltage installation.
The building installation.
The source of the Low-voltage installation.
Operating altitude: 2000m (6562 ft) Pollution degree: 2 EMC: EN 61326-1 Dimensions (WxHxD): 56 x 12 x 112 mm (2.2 x 0.5 x 4.4 in) Weight: 115g (0.25 lb) Accessories: Battery (installed), carry case and Instruction
Card.
Electrical Specications
Accuracy is ± (% reading + number of digits) at 23°C/73.4°F ± 5°C/41°F < 80% RH.
9
Page 16
Function Ranges Resolution Accuracy
400.0mV 0.1mV ± (1.5%+ 5 D)
4.000V 0.001V
ACV
Frequency Response: 50 ~ 500Hz AC Conversion Type: AC Coupled Average Sensing, RMS
Indication.
Input Impedance: 10M, <100pF. Overload protection: 600V rms.
Function Ranges Resolution Accuracy
DCV
Input Impedance: 10M, <100pF. Overload protection: 600V rms.
Function Ranges Resolution Accuracy
ohm
Open Circuit Voltage: 0.4V * There is a little rolling less than ± 2% Overload protection: 600V rms.
40.00V 0.01V
400.0V 0.1V
600V 1V
400.0mV 0.1mV ± (0.7%+ 5 D)
4.000V 0.001V
400.0V 0.1V
600V 1V ± (0.7%+ 5 D)
400.0 0.1 ± (0.9%+ 5 D)
4.000K 0.001K
400.0K 0.1K
4.000M 0.001M
40.00M* 0.01M
10
± (0.9%+ 5 D)
± (0.6%+ 2 D)40.00V 0.01V
± (0.9%+ 2 D)40.00K 0.01K
± (1.5%+ 5 D)
Page 17
CONTINUITY CHECK Continuity Threshold: Approx. <50 Continuity Indicator: 2.7 KHz Tone Buzzer. Input Protection: 600V rms..
Function Ranges Resolution Accuracy
40.00nF 0.01nF ± (5%+ 0.4nF)
400.0nF 0.1nF
Cap
Measuring Time: <30sec. (400.0µF range),
Overload protection: 600V rms.
Function Ranges Resolution Accuracy
Hz
Sensitivity: > 10Vp-p (40KHz range)
The signal must have positive and negative waveform of a cycle. Max. Sensitivity: 600V rms. Overload protection: 600V rms.
Function Ranges Resolution Accuracy
% 0.1 - 99.9% 0.1%
*: 30% Duty 70%,
4.000µF 0.001µF
40.00µF 0.01µF
400.0µF 0.1µF
<10sec. (40.0µF range), <3sec. (other range)
40.00Hz 0.01Hz
400.0Hz 0.1Hz
4.000KHz 0.001KHz
40.00KHz 0.01kHz
> 1.5Vp-p (other range)
± (2.9%+ 5D)
± (0.3%+ 5 D)
± (0.5%+ 10
D)*
11
Page 18
Square Wave (5 Hz ~ 1KHz) Sensitivity: 1.5Vp-p Overload protection: 600V rms.
Function Ranges Resolution Accuracy
ACA
400.0µA 0.1µA
4.000mA 0.001mA
± (1.5%+ 5 D)
Frequency Response: 50 ~ 500Hz AC Conversion Type: AC Coupled Average Sensing, RMS
Indication.
Input Impedance: Approx. 3K Overload protection: 600V rms.
Function Ranges Resolution Accuracy
DCA
400.0µA 0.1µA
4.000mA 0.001mA
± (0.9%+ 5 D)
Input Impedance: Approx. 3K Overload protection: 600V rms. DIODE TEST Test Current: Typical. 350µA Open Circuit Voltage: Max. 1.8V DC Input Protection: 600V rm.
- EMC: EN61326-1.
This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference.
12
Page 19
MAINTENACE
If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order
to isolate the cause of the problem.
1. Check the battery. Replace the battery
immediately when the “ symbol appears on the LCD.
2. Review the operating instructions for possible mistakes in operating procedure.
Except for the replacement of the battery, repair of the meter should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately Do not attempt to repair this Meter. It contains no user­serviceable parts. Repair or servicing should only be performed by qualified personnel.
TROUBLE SHOOTING
If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedure as described in this user’s manual.
If the instrument voltage-resistance input terminal has subjected to high voltage transient (caused by lightning or switching surge to the system) by accident or abnormal conditions of operation, the series fusible resistors will be blown off (become high impedance) like fuses to protect the user and the instrument. Most measuring functions through this terminal will then be open circuit. The series fusible resistors and the spark
13
Page 20
gaps should then be replaced by qualified technician. Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service.
Battery Replacement
Refer to the following figure to replace the batteries: