PC-5
Power Adaptor
The PC-5 Power Adaptor is supplied as an optional
accessory for the Amprobe DM-5 Power Quality
Analyzer. The PC-5 provides power to the instrument
from the circuit under test.
Power supply input terminal
(VN, V1)
Power switch
• Inspect the power adaptor before and after
using it to ensure that it is in good working
condition.
• Power off the power adaptor before connecting
to DM-5.
• Connect the power adaptor to DM-5 rst, then
connect to the circuit under test.
• Use supplied DM-5 test leads (TL-DM-5) only.
• Never disconnect the power adaptor when it is
energized during measurement.
• Remove all cords/leads from the power adaptor
before replacing the fuse.
• Replace a blown fuse with the exact replacement
part only.
• Do not operate the power adaptor with covers
removed or with the case open. Hazardous
voltage exposure is possible.
Plug (VN, V1)
DM-5
Power plug
SYMBOLS
Caution! Risk of electric shock.
Caution! Refer to the explanation in this
W
manual.
The equipment is protected by double
T
insulation or reinforced insulation.
Fuse.
I
Underwriters Laboratories (applies to
Canada and U.S.A.)
Do not dispose this product as unsorted
municipal waste. Contact aqualied
=
recycler.
SAFETY INFORMATION
W
Warning!
To avoid possible electric shock or personal injury:
• If the power adaptor is used in a manner not
specied by the manufacturer, protection
provided by the power adaptor may be affected.
• Do not connect the power adaptor to any circuit
which exceeds AC 240 V.
• Do not use the power adaptor around explosive
gas, vapor, or in damp or wet environments.
• Do not use the power adaptor if it appears
damaged. Inspect the power adaptor before
use. Look for cracks or missing plastic. Pay
particular attention to the insulation around the
connectors, cord and enclosure.
USING PC-5
Do not connect the power adaptor to
circuits which exceed AC 240 V.
Connect the PC-5 power adaptor according to below
steps:
1. Ensure the power adaptor switch is OFF.
2. Connect the plugs of the power adaptor to VN
and V1 terminals on DM-5 and power plug to the
power connector on DM-5 respectively.
3. Connect the test leads to VN and V1 terminals of
the power adaptor.
4. Connect the alligator clips of the test leads to the
circuit under test.
5. Power ON the PC-5 power adaptor
6. Power ON the DM-5.
>240 V
④
①③ ⑤
②
⑥
21
Disconnect the PC-5 power adaptor:
1. Switch the PC-5 power adaptor OFF.
2. Remove the alligator clips/test leads from the
circuit under test.
3. Remove the test leads from VN and V1 terminals
of the PC-5 power adaptor.
4. Remove the PC-5 power plug from the power
connector on DM-5 and remove the plugs of the
power adaptor from VN and V1 terminals on
DM-5 respectively.
FUSE REPLACEMENT
W
Warning!
Ensure the PC-5 is disconnected from energized
circuit and is disconnected from DM-5.
For safety, only use the exact replacement
parts.
To replace a fuse:
1. Ensure the unit is in the OFF position.
2. Loosen the screw on the fuse cover and remove
the fuse cover.
3. Remove the fuse and replace with exact fuse
replacement (F 0.5 A / 600 V, Ø6.3 x 32 mm) only.
4. Put the fuse cover back and tighten the screw.
SPECIFICATIONS
Cable length Approx. 180 mm
Max input voltage 240 Vrms
Rated rating
Fuse rating
Dimension
(L x W x H)
Weight 0.12 kg (0.26 lb)
Accessory
100 to 240 Vac, 45 to 65 Hz,
20 VA max.
AC 500mA / 600V, Fast acting,
6.3 x 32mm
Approx. 76 x 55 x 46 mm
(excludes the cord and plug)
1 x Fuse (installed), instruction
manual
3 4
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in
material and workmanship for one year from the date
of purchase unless local laws require otherwise. This
warranty does not cover fuses, disposable batteries
or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or
handling. Resellers are not authorized to extend any
other warranty on the behalf of Amprobe. To obtain
service during the warranty period, return the product
with proof of purchase to an authorized Amprobe
Service Center or to an Amprobe dealer or distributor.
See Repair Section for details. THIS WARRANTY IS YOUR
ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER
EXPRESS, IMPLIED OR STATUTORY - INCLUDING IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE
OR MERCHANTABILITY, ARE HEREBY DISCLAIMED.
MANUFACTURER SHALL NOT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow
the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of
liability may not apply to you.
Repair
All Amprobe returned for warranty or non-warranty
repair or for calibration should be accompanied
by the following: your name, company’s name,
address, telephone number, and proof of purchase.
Additionally, please include a brief description of the
problem or the service requested and include the
test leads with the meter. Non-warranty repair or
replacement charges should be remitted in the form
of a check, a money order, credit card with expiration
date, or a purchase order made payable to Amprobe.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check
your battery before requesting repair. During
the warranty period, any defective test tool can
be returned to your Amprobe distributor for an
exchange for the same or like product. Please check
the “Where to Buy” section on www.Amprobe.com
for a list of distributors near you. Additionally, in the
United States and Canada, in-warranty repair and
replacement units can also be sent to an Amprobe
Service Center (see address below).
Non-Warranty Repairs and Replacement – US and
Canada
Non-warranty repairs in the United States and
Canada should be sent to an Amprobe Service Center.
Call Amprobe or inquire at your point of purchase for
current repair and replacement rates.
In USA In Canada
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 888-993-5853 Tel: 905-890-7600
Fax: 425-446-6390 Fax: 905-890-6866
11/2015, 6006999 A ©2015 Amprobe.