Amprobe DM-II-PLUS Data sheet

Page 1
Data Sheet
DM-II Plus
Power Quality Recorder
Amprobe’s DM-II PLUS is a full-featured three phase power quality recorder to maintain, diagnose and troubleshoot electrical systems. It measures and records a broad spectrum of power quality parameters. Easy to use, it’s capable of measuring and recording voltage, current, voltage anomalies (sags or surges), harmon­ics, energy and power (active, reactive and apparent), power factor (true and displacement), and frequency. This unique product comes as a complete kit with current transducers and an increased memory size for data storage, larger display size, and real-time downloading using Amprobe’s unique Download Suite software.
No hassle warranty
No waiting.
No shipping charges.
(note: $500 MSLP limit)
AC Current up to 1000A, AC Voltage, Active, Reactive and Apparent Power, Energy, Peak Demand & Power Factor
All readings are True RMS
5 built-in selectable languages: English, French, Italian, German and Spanish
User selectable rates allow recording from one hour to
several months
Works with single & three phase systems (Y & delta)
Readings and charts can be viewed on the DM-II LCD screen or downloaded to a PC
Capable of recording all parameters (single or three phase)
simultaneously
Optional transducers available for 100A and 3000A (flexible)
current capability.
Amprobe® Test Tools
www.Amprobe.com
Page 2
DM-II Plus Power Quality Recorder
General Specifications
Mechanical Features Dimensions: 444.5(L) x 273.05(La) x 190.5(H) mm
17.50”(L) x 10.75” (La) x 7.50”(H) Weight: 11.5 Lb (5.2kg) Internal power supply: 6 batteries 1.5V D size NEDA 13A, IEC L20R Battery Life: 22 hours External power supply Use only Amprobe power supply Adapter code DMT-EXTPS. Display: dot matrix with backlight resolution 128 x 128 dots (16384 dots) dot size 0.5mm x 0.5mm visible area 73mm x 73mm (2.9” x 2.9”) No. of samples per period 128 Clamp: Opening: 53 mm (2.15”) Maximum diameter of the cable: 50 mm (2.00”) Reference temperature: 23°C ± 1°C (73°F ± 2°F) Operating temperature: 0°C to 50 °C (32°F to 122°F) Relative humidity: <70% Storage temperature: -10°C to 60 °C (14°F to 140°F) Storage humidity: <80% Location: Indoor operation, < 2000 m EMC/EMI/ESD EN61326-1:2006
Safety
The instrument complies to the standards: EN 61010-1 :2002 Insulation: Class 2 / Pollution Degree 2 Over-voltage category: CAT III 370V~ (Phase-Earth) CAT III 635V~ (Phase-Phase) Clamps: IEC 61010-2-032 Ed. 2.0 Phase Sequence Detection: EN 61557-7:2003
Data Sheet
Specifications Accuracy
Voltage measurement (Autoranging)
Range Accuracy Resolution Input impedance 15-370V ±(0.5% + 2 digit) 0.2V 300kW (phase-neutral) 310-635V ±(0.5% + 2 digit) 0.4V 600kW (phase-phase)
Voltage Anomalies Detection (Manual Selection of Range)
Voltage Range Accuracy Resolution Input impedance 15-370V ±(0.5% + 2 digit) 0.2V 300kW (phase-neutral) 30- 635V ±(0.5% + 2 digit) 0.4V 600kW (phase-phase)
Current measurement (DM-II Plus only)
Range Accuracy Resolution Input impedance Protection against overloads
0.005-0.26V ±(0.5%+2digit) 0.0001V 100kW 5V 0.26-1V 0.0004V
Current measurement (Using DM-CT-HTA)
Range Accuracy Resolution Protection against overloads 5 to 1000 A ±(1.5% of range) 0.1 A 600 V
Minimal Current measurable is equal to 1.5% of Clamp Full Scale
Amprobe® Test Tools
73°F± 2°F (23°C ± 1°C) with relative humidity < 75%
www.Amprobe.com
Page 3
DM-II Plus Power Quality Recorder
Specifications, cont.
Current measurement (Using AM-FLEX 33)
Range Accuracy Resolution Protection against overloads 15 to 3000 A ±(1.5% of range) 0.1 A 600 V
Minimal Current measurable is equal to 1.5% of Clamp Full Scale
Power measurement (cos : 0.5c[positive] – 0.5i[negative])
Value Ranges Accuracy Resolution Active power 0 – 999.9W ±(1.5% + 2 digit) 0.1W 1kW – 999.9kW ±(1.5% + 2 digit) 0.1kW 1MW – 999.9MW ±(1.5% + 2 digit) 0.1MW Reactive power 0 – 999.9VAR ±(1.5% + 2 digit) 0.1VAR 1kVAR – 999.9kVAR ±(1.5% + 2 digit) 0.1kVAR 1MVAR – 999.9MVAR ±(1.5% + 2 digit) 0.1MVAR Apparent power 0 – 999.9VA ±(1.5% + 2 digit) 0.1VA 1kVA – 999.9kVA ±(1.5% + 2 digit) 0.1kVA 1MVA – 999.9MVA ±(1.5% + 2 digit) 0.1MVA Active energy 0 – 999.9Wh ±(1.5% + 2 digit) 0.1Wh 1kWh – 999.9kWh ±(1.5% + 2 digit) 0.1kWh 1MWh – 999.9MWh ±(1.5% + 2 digit) 0.1MWh Reactive energy 0 – 999.9VARh ±(1.5% + 2 digit) 0.1VARh 1kVARh – 999.9kVARh ±(1.5% + 2 digit) 0.1kVARh 1MVARh – 999.9MVARh ±(1.5% + 2 digit) 0.1MVARh
Cos measurement
Cos Resolution Accuracy (expressed in degrees) 0 to 0.20 0.01 0.6
0.21 to 0.50 0.01 0.7
0.51 to 0.80 0.01 1
Measurement of Harmonics Voltage
Range Accuracy Resolution DC – 25h ±(5.0% + 2 digit) 0.1V 26h – 33h ±(10.0% + 2 digit) 0.1V 34h – 49h ±(15.0% + 2 digit) 0.1V
The voltage harmonics will be null under the following threshold:
- DC: if <1V or <2% of 1st harmonic
- 1st harmonic: if <2V
- 2nd to 49th: if <1V or <2% 1st harmonic
Current
Range Accuracy Resolution DC – 25h ±(5.0% + 2 digit) 0.1A 26h – 33h ±(10.0% + 2 digit) 0.1A 34h – 49h ±(15.0% + 2 digit) 0.1A
The current harmonics will be null under the following threshold:
- DC: if <2% of 1st harmonic or < 0,2% of clamp full scale
- 1st harmonic: if < 0.2% of clamp full scale
- 2nd to 49th: if<2% 1st harmonic or < 0.2% of clamp full scale Setting the FLEX option the DC component will be ignored.
Frequency Measurement
Instrument set to 50Hz Range Resolution Accuracy 47 to 53 0.1Hz ±(1.0% + 1 digit) Instrument set to 60Hz Range Resolution Accuracy 57 to 63.6 0.1Hz ±(1.0% + 1 digit)
Data Sheet
www.Amprobe.com
Page 4
DM-II Plus Power Quality Recorder
Included Accessories
DMT-EXTPS External power supply 12VDC DM-CT-HT (code 1 pcs) 3 clamp meters 1000A/1V KITENERGY3 4 cables and alligators for voltage measurement Download Suite 2.2 1 Amprobe Custom Software CD C232NG1 Serial Cable
Optional Accessories
AM-FLEX33 Flexible current transducer, 3000 A DM-CT-100 Current transducer, 100A
Data Sheet
Amprobe® Test Tools
website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 tel: 877-AMPROBE
Amprobe® Test Tools Europe
In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0
Amprobe® Test Tools
©2007 Am probe Test Tools. All rights res erved. 2/2008 3306952 Rev A
www.Amprobe.comwww.Amprobe.com