Amprobe DM73C Operating Manual

Digital Multimeter
Pen Style DMM
Users Manual
Manual de uso
·
Mode d'emploi
·
Bedienungshandbuch
·
Manuale d'Uso
·
DM73CDM73C
1
CAT III - 300V
CAT II - 600V
V
Ω
MAX
OFF
V
H
Ω
SHIFT
DC
AC
0
10 3020
2
3
4
COM
Mk
mV
H S
Ω
+
DM73C
DIGITAL
MULTIMETER
5
6
DM73C
Digital Multimeter
Users Manual
Manual de uso
Mode d’emploi
Bedienungshandbuch
Manuale d’Uso
PN 2728873 August 2006
©Amprobe® Test Tools. All rights reserved. Printed in Taiwan.
DM73C
Digital Multimeter
Users Manual
Manual de uso
Mode d’emploi
Bedienungshandbuch
Manuale d’Uso

English

English
WARRANTY
Your Amprobe® product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe
®
Test Tools Service Center or
to a Amprobe
®
dealer or distributor. See Repair Section above for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY
- INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
1
CERTIFICATIONS AND PRECAUTIONS
The DM73C instrument is UL, cUL, and EN61010-1 certified for Installation Category II – 600V and Category III – 300V. It is recommended for use with local level power distribution, appliances, portable equipment, etc, where only smaller transient overvoltages may occur, and not for primary supply lines, overhead lines and cable systems. Do not exceed the maximum overload limits per function (see specifications) nor the limits marked on the instrument itself. Never apply more than 600VDC between the test lead and earth ground. Exercise extreme caution when: measuring voltage >20V // servicing CRT equipment. ■ Inspect DMM, test leads and accessories before every use. Do not use any damaged part. Never ground yourself when taking measurements. Do not touch exposed circuit elements or probe tips. Do not operate instrument in an explosive atmosphere.
EXPLANATION OF SYMBOLS
INTRODUCTION
The DM73C is a probe-type digital multimeter capable of measuring DC and AC voltage, resistance, diode and continuity. Its controls are: Volts (V), Ohms ( ), Diode Test and Continuity Beeper (
), On- Off, AC/ DC and Hold. (See page 3) 1. V - Ω input. 2. Function selector. 3. HOLD button. 4. SHIFT button for AC / DC or Diode /Continuity. 5. LCD Display. 6. COM input.
DANGER High Voltage
ATTENTION Refer to Manual
Protective Conductor Terminal
This Instrument has double insulation
Direct Current
Alternating Current
2
MEASURING PROCEDURES
Note: When connecting or disconnecting test leads to or from a
circuit, always first turn off power to the circuit under test and discharge all capacitors.
DC / AC Voltage Measurement
Set the Function switch to “V”. Select AC or DC by pressing the mode selector button (AC or DC is displayed). Connect the instrument to the circuit and read the measured voltage in the display.
Resistance Measurement
Set the Function switch to “ ”. Connect the instrument across the resistance and read the value in the display. When measuring high resistance values, take care not to touch the test leads.
Continuity Measurement
Set the Function switch to . Press the mode selector button once, so that appears (
) in the LCD. Connect the instrument across the device or wire to be tested. Beeper will sound when continuity is established. The beeper also sounds when changing functions, modes, or for Probe Hold.
Diode Measurement
Set the Function switch to . Press the mode selector button twice, so that appears (
) in the LCD. Connect the instrument across the device to be tested. The forward voltage drop of a good diode is about 0.6V. An open or reverse biased diode will read “OL”.
Data Hold
Push the HOLD button to “freeze” the measurement reading and then remove the test leads while the reading remains displayed. HOLD is useful when it is necessary to pay very close attention to your work. Pushing the HOLD button again releases the display.
3
Automatic Shutdown
This function causes the meter to enter power saving mode after approximately 10 minutes. Disable automatic shutdown by holding the shift button down while turning the meter on.
MAINTENANCE
In Case of Difficulties In the case of improper operation of the
meter, first review the operating instructions for possible errors in operation. Inspect and check test leads for continuity. Check the condition of the batteries. The battery “
” symbol appears when the voltage falls below the level where accuracy is guaranteed. Replace batteries immediately.
Battery Replacement
Warning: In order to avoid electrical shock,
remove the test lead before opening the case. To replace the batteries ( 2 – LR44) unscrew the battery hatch screw and remove the old batteries. Install the new batteries observing the diagram in the battery area.
Cleaning Procedure
Gently wipe dirt from the surface of the unit with a soft cloth moistened with a small amount of water or neutral cleanser. Do not use benzene, alcohol, acetone, ether, paint thinner, lacquer or ketone solvents on the units, under any circumstances as these may cause deformation or discoloration.
REPAIR
All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company’s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with
4
expiration date, or a purchase order made payable to Amprobe
®
Test Tools. In-Warranty Repairs and Replacement – All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe
®
Test Tools distributor for an exchange for the same or like product. Please check the “Where to Buy” section on www.amprobe.com
for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe
®
Test Tools Service Center (see below for address). Non-Warranty Repairs and Replacement – US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe
®
Test Tools Service Center. Call Amprobe® Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe
®
Test Tools Amprobe® Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 888-993-5853 Tel: 905-890-7600 Fax: 425-446-6390 Fax: 905-890-6866 Non-Warranty Repairs and Replacement – Europe European non-warranty units can be replaced by your Amprobe
®
Test Tools distributor for a nominal charge. Please check the “Where to Buy” section on www.amprobe.com
for a list of distributors near you. European Correspondence Address* Amprobe
®
Test Tools Europe P.O. Box 1186 / 5602 BD Eindhoven / The Netherlands *(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
5
SPECIFICATIONS
General Specifications
Display: 3- 3/ 4 digit LCD, 3400 count Measuring rate: 2.5/ second nominal Bargraph: 34 segments – updated 20 readings per second Operating Temp. range: 0 to 40° C, 80% RH Storage Temp. range: -20 to 60° C, 70% RH Environmental: Intended for Indoor use, Altitude up to 2000 m. Measurement Accuracy: x0.1/ C° Batteries: 2x LR44, SR44 or S76 Life: 100 hours nominal Auto Power Off: after 10 minutes Dimension: 7.8” x 1.1” x 1.4” Weight: .21 lb. Accessories: Operating manual, test lead with alligator clip, 2 batteries (installed), spare tip.
Approvals: Safety: Conforms to EN61010- 1: Cat II - 600V, Cat III – 300V ; Class 2, Pollution degree II; UL3111-1. EMC: Conforms to EN61326-1. The TL73B test lead and alligator clip is UL approved for use only with the DM73C.
This product complies with requirements of the following European Community Directives: 89/ 336/
EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should
6
exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference.
Electrical Specifications
Accuracy at 23°C ± 5°C, < 75 % RH, guaranteed for one year.
DC Volts
Ranges: 340mV, 3.4, 34, 340V, 600V Accuracy: ± (0.5% rdg + 2 dgt) Input Impedance: 340 mV range: >100M , other ranges: 10M Protection: 600VDC or AC rms
AC Volts
Ranges: 3.4V, 34, 340, 600V Accuracy: ± (1.5 % rdg + 8 dgt) (50 - 500Hz) Input Impedance: 10M Protection: 600VDC or AC rms.
Resistance
Ranges: 340 , 3.4, 34, 340 k , 3.4, 34 M Accuracy: 340 - 340k: ± (1.0 % rdg + 4 dgt)
3.4M: ± (1.5 % rdg + 4 dgt) 34 M: ± (3.0 % rdg + 5 dgt) Max. open circuit voltage: 340Ω range - 1.2V; all others: - 0.45V Protection: 500VAC or DC.
Diode Test
Range: 3.4V Accuracy: ± (2.0%rdg + 3 dgt) Resolution: 0.1mV in 3.4V range Short circuit current: 1.0mA Max open circuit voltage: 3.0VDC Audible indication: < 0.2V Overload prot.: 500VDC or AC rms
7
Continuity
Display response: <0.5s Continuity threshold: 35 Overload prot.: 500VDC or AC rms
Accessories / User Replaceable Parts
TL73B Test lead with alligator clip VC11 Vinyl Case TP73B Replaceable Probe tip Battery Type SR44, LR44, or S76
8
DM73C
Digital Multimeter
Users Manual
Manual de uso
Mode d’emploi
Bedienungshandbuch
Manuale d’Uso
Spanish

Español

GARANTIA
Su producto Amprobe® estará libre de defectos de material y mano de obra durante 1 año a partir de la fecha de adquisición. Esta garantía no cubre fusibles, baterías descartables o daños que sean consecuencia de accidentes, negligencia, uso indebido, alteración, contaminación o condiciones anormales de operación o manipulación. Los revendedores no están autorizados a extender ninguna otra garantía en nombre de Amprobe. Para obtener servicio durante el período de garantía, regrese el producto con una prueba de compra a un centro de servicio autorizado por Amprobe
®
de equipos de comprobación o a un concesionario o distribuidor de Amprobe. Consulte la sección Reparación que aparece más arriba para obtener detalles. ESTA GARANTÍA CONSTITUYE SU ÚNICO RESARCIMIENTO. TODAS LAS DEMÁS GARANTÍAS, TANTO EXPRESAS, IMPLÍCITAS O ESTATUTARIAS, INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE ADECUACIÓN PARA UN PROPÓSITO DETERMINADO O COMERCIABILIDAD, QUEDAN POR LA PRESENTE DESCONOCIDAS. EL FABRICANTE NO DEBERÁ SER CONSIDERADO RESPONSABLE DE NINGÚN DAÑO O PÉRDIDA TANTO ESPECIALES, INDIRECTOS, CONTINGENTES O RESULTANTES QUE SURJAN DE CUALQUIER CAUSA O TEORÍA. Debido a que ciertos estados o países no permiten la exclusión o limitación de una garantía implícita o de los daños contingentes o resultantes, esta limitación de responsabilidad puede no regir para usted.
1
SIGNIFICADO DE LOS SÍMBOLOS
Advertencias y Precauciones
Nota: El símbolo en el frontal del DM73C significa “Consulte las
instrucciones de uso”. Este instrumento está homologado según UL, cUL, y EN61010- 1 para la Categoría de Instalación II – 600V, Categoría de Instalación III – 300V. Su uso está recomendado en distribución local de energía, electrodomésticos, equipos portátiles, etc, donde solamente pueden producirse bajos niveles transitorios de sobre tensión; pero no en líneas principales de suministro, líneas aéreas y sistemas de cableado. No supere nunca los límites de entrada para las diferentes funciones (vea las especificaciones), ni los límites marca dos en el propio instrumento. No aplique nunca más de 600 V CC entre la punta de prueba y tierra. Extreme las precauciones: al medir tensión >20 V // al trabajar con pantallas TRC n Inspeccione siempre el multímetro, las puntas de prueba, los conectores y los accesorios antes de cada uso. No utilice ningún componente que esté dañado. No se ponga Ud. a tierra cuando esté tomando medidas. No toque partes expuestas de los circuitos. No utilice el instrumento en ambientes potencialmente explosivos.
Descripción
El DM73C es un multímetro digital de tipo sonda, con capacidad para medir tensión CC y CA, resistencia y continuidad. Tiene los siguientes controles: Voltios (V), Ohmios ( ), Prueba de Diodos y Tono de Continuidad(
), On- Off, AC/ DC y Retención (Hold). La
unidad destaca por su diseño reducido y ligero, con un manejo
¡Atención! Consulte las Instrucciones de Uso Puede haber tensión peligrosa en los terminales
Conexión a tierra
Este instrumento tiene doble aislamiento
Corriente continua
Corriente alterna