Amprobe DGC-1000A, GP-2A Catalog Page

GP-2A Ground Resistance & Resistivity Tester
DUAL RATED
For installation and troubleshooting, this instrument provides accurate and reliable measurements of ground resistance and soil resistivity to help you reduce power quality problems.
• Measures earth ground resistance with 3-point (fall of potential) or 2-point tests
• Calculates resistivity with 4-point test
FEATURE GP-2A
Ground Resistance
Ground Resistivity
AC Currrent
AC Volt age 0 V – 460 V
INCLUDED ACCESSORIES: User manual, batteries (installed), connection cables, 4 ground stakes, PC software and USB cable, carrying case
• Autoranging
• Store up to 999 measurements
• Create custom reports by downloading data to a PC
1999
Ω
314 k
Ω
m
240 V
GP-2A
Recommended
Accessories
AMPRB-ET4
Set Earth Testing Accessory Kit
(Replacement part)
DGC-1000A Clamp-on Ground Resistance Tester
User-friendly and accurate, the DGC-1000A helps you work safely without test leads or auxiliary electrodes. The on-board memory and data logging features improve efficiency.
• Accurate ground resistance measurements from
0.025 to 1500 Ohms
• True-RMS current and leakage current measurements
• Accurate readings in less than 10 seconds
• Audible alert if continuity beep if the resistance is below 40 Ohms
FEATURE DGC-1000A
Ground Resistance
Ground Resistivity
AC Currrent
AC Volt age
INCLUDED ACCESSORIES: Carrying case, user manual, resistance calibration plate, batteries (installed)
TOP R ATED
“Great instrument. An advantage to have.”
“On a motor grounding job where 800hp motors were failing on a continuous basis, we were able to pinpoint the lack of proper grounding that was causing harmonics and energizing armature shaft, to the point where it was reading 400v. On that job alone this tool proved invaluable and allowed the customer to save thousands on downtime and predictive maintenance. This tool will become a gem in your tool-bag just clamp it on and take live readings without breaking connections, I highly recommend it”
- DGC-1000A customer reviews
• Data logging capability - 116 records
• Individual data point recordings
• User selectable high and low ohm audible alerts
• Auto power-off (can be disabled)
• Low battery indicator
^
^
1500 Ω
30.00 A
0.025 Ω
0.2 mA
Power Quality / Insulation / Ground Resistance
DGC-1000A
35