Amprobe ACD-23SW Specifications

Data Sheet
ACD-23SW
Swivel Clamp Meter
New patented rotating head clamp design allows easy viewing of measurements in tight or inconvenient to reach places. Simply rotate the body of the meter to get an unobstructed view of the LCD display. Rich set of features and CAT III 600V safety reading for use in electrical and HVAC applications.
n TRMS Measurement
n 180 degree rotating head for the perfect display viewing
n Advanced VoltTect non-contact voltage detection
n Slim jaw design with one hand operation
n Measures AC Current up to 400 ACA, AC/DC, Voltage up to
600V, Resistance and Capacitance
n Temperature measurement
No hassle warranty
No waiting.
No shipping charges.
Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot.
(note: $500 MSLP limit)
n Audible continuity
n Auto and manual ranging respectively for quick checks and
precise measurements
n Auto power off
n Data hold
n Accommodates conductors up to 1.18” (30mm) in diameter
n Safety CAT III 600 V
n Test leads, battery (installed), Users Manual, Carrying Case
and type-K thermocouple are included with the product
Amprobe® Test Tools
www.Amprobe.com
ACD-23SW Swivel Clamp Meter
Data Sheet
General Specifications
Display 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity Automatic, positive implied, negative polarity indication. Overrange (OL) or (-OL) is displayed. Zero Automatic. Low battery indication The “ Auto power off Approx. 10 minutes. Measurement rate 2 times per second, nominal. Operating Environment 0°C to 50°C / 32°F to 122°F at <70% relative humidity. Storage Ttemperature -20°C to 60° / -4°F to 140°F, 0 to 80% R.H. with battery removed from meter. Accuracy Stated accuracy at 74°F ±8°F, <75% relative humidity. Temperature Coefficient 0.1 × (specified accuracy) per °F, (32°F to 66°F, 82°F to 122°F). Altitude 6561.7 Feet (2000m). Jaw opening capability 30mm (1.18 in) conductor. Power 1.5 volt battery x2, R03/SIZE AAA. Isolated battery compartment. Battery life 150 hours typical with carbon-zinc. 300 hours typical with alkaline. Dimensions 306 × 135 × 30mm (12 × 5.3 × 1.2 in). Weight Approx. 157g (1.26lb) including battery. Safety Designed to meet IEC 61010-1 (EN61010-1) and IEC 61010-2-032 (EN61010-2-032), CATIII 600V class II
and pollution degree 2 indoor use comply with CE , UL
“ is displayed when the battery voltage drops below the operating level.
Electrical Specifications
DC Volts
Ranges 400mV, 4V, 40V, 400V, 600V Resolution 0.1mV Accuracy ±(0.5% rdg + 2 dgts) Input Impedance 400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ Overload Protection 600V DC or AC rms to measure millivolts, use “RANGE “ button to manually select 400mV range.
AC Volts (50Hz - 500Hz)
Ranges 4V, 40V, 400V, 600V Resolution 1mV Accuracy ±(1.2% rdg + 5 dgts)
±(2% rdg + 5 dgts) on 600V range
Input Impedance 4V:10M Ω;40V~600V:9.1MΩ Overload Protection 600V DC or AC rms
AC Current (50Hz - 60Hz)
Ranges 40A , 400A Resolution 0.01A Accuracy ±(2.0% rdg + 10 dgts) 50 ~ 60Hz Overload Protection 400A AC