Data Sheet
ACD-20SW
Swivel Clamp Meter
New patented rotating head clamp design allows easy viewing of
the measurements in tight or inconvenient to reach places. Simply
rotate the body of meter to get an unobstructed view of the LCD
display. Reach set of features and CAT III 600V safety reading for
use in electrical and HVAC applications.
n 180 degree rotating head for the perfect display viewing
n Advanced VoltTect non-contact voltage detection
n Slim jaw design with one hand operation
n Measures AC Current up to 400 ACA, AC/DC Voltage up to
600V, Resistance and Capacitance
n Audible continuity
n Auto and manual ranging respectively for quick checks and
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
“No Hassle” warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
precise measurements
n Auto power off
n Data hold
n Diode Test
n Accommodates conductors up to 1.18” (30mm) in diameter
n Safety CAT III 600 V
n Test leads, battery (installed), Users Manual, Carrying Case
are included with the product
Amprobe® Test Tools
www.Amprobe.com
ACD-20SW Swivel Clamp Meter
Data Sheet
General Specifications
Display 3¾ digit liquid crystal display (LCD) with a maximumreading of 3999.
Polarity Automatic, positive implied, negative polarityindication.
Overrange (OL) or (-OL) is displayed.
Zero Automatic.
Low Battery Indication The “ “ is displayed when thebattery voltage drops below the operating level.
Auto Power Off Approx. 10 minutes.
Measurement Rate 2 times per second, nominal.
Operating Environment 0°C to 50°C / 32°F to 122°F at <70% relativehumidity.
Storage Ttemperature -20°C to 60° / -4°F to 140°F, 0 to 80% R.H. withbattery removed from meter.
Accuracy Stated accuracy at 74°F ±8°F, <75% relativehumidity.
Temperature Coefficient 0.1 × (specified accuracy) per °F,(32°F to 66°F, 82°F to 122°F).
Altitude 6561.7 Feet (2000m).
Jaw Opening Capability 30mm (1.18 in) conductor.
Power 1.5 volt battery x2, R03/SIZE AAA.
Isolated Battery Compartment.
Battery Life 200 hours typical with carbon-zinc.400 hours typical with alkaline.
Dimensions 306 × 135 × 30mm (12 × 5.3 × 1.2 in).
Weight Approx. 157g (1.26lb) including battery.
Safety Designed to meet IEC 61010-1 (EN61010-1) andIEC 61010-2-032 (EN61010-2-032) , CATIII 600V class II
and pollution degree 2 indoor use comply with CE , UL
Electrical Specifications
DC Volts
Ranges 400mV, 4V, 40V, 400V, 600V
Resolution 0.1mV
Accuracy ±(0.5% rdg + 2 dgts)
Input Impedance 400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ
Overload Protection 600VDC or AC rms To measure millivolts, use “RANGE “ button to manually select 400mV range.
AC Volts (50hz - 500hz)
Ranges 4V, 40V, 400V, 600V
Resolution 1mV
Accuracy ±(1.2% rdg + 5 dgts)
±(1.5% rdg + 5 dgts) on 600V range
Input Impedance 4V:10M Ω;40V~600V:9.1MΩ
Overload Protection 600 VDC or AC rms
AC Current (50hz - 60hz)
Ranges 40A , 400A
Resolution 0.01A
Accuracy ±(2.0% rdg + 6 dgts) 50 ~ 60Hz
Overload Protection 400A AC
Amprobe® Test Tools