Ampeg B-15R User Manual

OWNER’S GUIDE
Thank you for selecting the Ampeg B-15R Portaflex Bass Amplifier. Revived from the past and enhanced for the present, this limited production model offers all of the best features of the 1960’s classic plus more. In order to get the most out of your new amplifier, please read these instructions before its use.
FEATURES:
• 0db and -15dB Input Jacks • Tube Bias Select Switch • Patented “Flip Top” Enclosure
• Ultra High / Ultra Low Boosts • Impedance Selector (8/4 Ohms) • Ampeg Vintage 15” Speaker
• Three Band EQ • XLR Balanced Line Out Jack • 100 watts RMS
• Five Position Mid Freq Select • Line Out Level Control • All Tube Design
• Master Volume Control • Pre/Post Select Switch • Removable Dolly Board w/Casters
• Half-Power Switch • Ground Lift Switch • Proudly Made In America
OUT
IN
AS
NEEDED
AS
NEEDED
IN
IN
AS
NEEDED
AS
NEEDED
OUT
OUT
AS
NEEDED
AS
NEEDED
OUT
IN
AS
NEEDED
AS
NEEDED
SOME SUGGESTED SETTINGS:
JAZZ:
FUNK:
ROCK:
COUNTRY:
B-15R PORTAFLEX
B-15R PORTAFLEX
1 2
4
3
6 7 9 10 11 12 135 8
1,2: INPUT JACKS: Connect the signal cable from your instrument to either of these jacks: if your bass has active electronics, its output may be “hotter” than normal – the -15dB jack is padded to accommodate such sig­nals. If your bass has normal pickups, use the 0dB jack.
3,4: ULTRA HI / ULTRA LO BOOSTS: Engage these pushbutton switches to boost the highs or lows as desired. These switches activate the boosts at their “in” positions.
5: GAIN CONTROL: Adjust this control to suit your instrument’s signal level and your playing style – lower output levels and softer playing styles require a higher setting of the Gain control than high output and “hard” playing styles. Proper adjustment of this control will give you clean sound with the lowest noise.
6: BASS CONTROL: Adjust the low frequency output of the amp with this control: turn the control to the left for less; to the right for more. This control allows a range of ±25dB at 40Hz.
7: MID CONTROL: Adjust the midrange frequency out­put of the amp with this control: turn the control to the left
for less; to the right for more. This control allows a range of ±34dB at the selected frequency (see #8).
8: FREQUENCY: This control allows you to select one of five midrange frequencies: 200, 400, 900, 1.5k or
2.5kHz. The setting of this control determines the effec­tive range for the Mid control.
9. TREBLE CONTROL: Adjust the high frequency out­put of the amp with this control: turn the control to the left for less; to the right for more. This control allows a range of ±30dB at 4kHz.
10: MASTER: Set the overall output level of the amplifi­er with this control. When the Post/Pre switch (#22) is at the IN (“Post”) position, this control also affects the level at the Balanced Line Out jack (#24).
11: HALF-POWER SWITCH:For situations where lower playing volumes are appropriate, flip this switch to the “60W” (down) position. This, in effect, bypasses one-half of the output amplification devices, producing one-half the output power as before. Of course, when full output is desired, flipping the switch to the “100W” (up) position returns the amplifier to its original 100 watt state.
Note: In the 60 watt position the amplifier will deliver approximately 40 watts into the internal speaker. To deliver the full 60 watts into the internal 8 ohm speaker, set the impedance switch (#18) to the 4 ohm setting. Operation at either impedance setting is acceptable and will yield some variances in the tonality of the unit. Experiment with these settings to determine which sound best suits your personal taste..
12: STANDBY SWITCH: Activate the amplifier with this switch, after the Power switch has been turned on.
Always turn this switch off first, on last. Turn on the Power switch (#13) at least 30 seconds before turn­ing on the Standby switch. During breaks, turn the
Standby switch off, leaving the Power switch on. This helps promote longer tube life.
13: POWER SWITCH: Turn on the main AC power with this switch. Always turn this switch on first, off last.
Turn on the Standby switch (#12) at least 30 sec­onds after turning on the Power switch.
17
MODEL: SERIAL: LINE: V ~ Hz WATTS: MAX
B-15 B1500691242 120 60
14
20 21
24
22
23
15
16 18
19
14: AC LINE IN: Use the supplied power cord to connect the amplifier to a suitable source of A.C. voltage. This is a grounded, three-wire cord and must be connected to a properly grounded outlet. DO NOT attempt to defeat the ground connection of the power cord! See the serial number label for power ratings.
15: FUSE: This protects the amplifier from damage to overload conditions or power line surges. If the fuse blows, replace it only with the same size and type.
16. BIAS SELECT: Allows for instant bias adjustment when the TYPE of output tube is changed. The setting of this switch must match the type of tube being used! The amplifier is shipped with 6L6 tubes installed.
17. SPEAKERS: Connect the amplifier to the internal speaker and/or an extension speaker cabinet using these jacks. Use heavy duty speaker cables terminated with the proper connectors. The total speaker impedance can not be less than 4 ohms. (Be sure to match the Impedance Selector switch [#18] to the cabinet imped­ance.) The B-15R’s cabinet impedance is rated at 8 ohms.
18. IMPEDANCE SELECTOR: Use this switch to match the amplifier to the TOTAL impedance of your speaker cabinet(s). Use the following chart to determine the total impedance of parallel cabinets:
CABINET NUMBER OF TOT AL
IMPEDANCE CABINETS IMPEDANCE
16 ohms 2 8 ohms 16 ohms 4 4 ohms
8 ohms 2 4 ohms
19: LINE OUT: Used with the Line In jack (#20), this may serve as an effects loop: The signal from this jack would go to the input of the effect. Alternate uses for this jack include providing an unbalanced line level signal for con­necting to an external amplifier or mixing console. The signal at this jack is affected by the Master control (#10).
20: LINE IN: Used with the Line Out jack (#19), this may serve as an effects loop: The signal from this jack would come from the output of the effect. Alternate uses for this jack include providing a means to tap directly into the internal power amplifier, bypassing the input stages com­pletely.
21. LINE OUT LEVEL: This controls the output level of the signal at the Balanced Line Out jack (#24).
22: POST/PRE SWITCH: This switch determines whether or not the signal at the Balanced Line Out jack (#24) is affected by the settings of the tone and master level controls. With the switch at the OUT (“Post”) pos­tion, signal is affected; with the switch IN (“Pre”), the sig­nal is not affected.
23: LIFT/GND SWITCH: This switch lifts the ground of the Balanced Line Out jack (#24) at the IN position. Engage this switch only if there is excessive buzzing or hum coming from the amplifier due to ground loops.
24: BALANCED LINE OUT: This jack provides a bal­anced line level signal for connecting to a mixing console, recording device or external amplifier.
25: HIGH FREQUENCY ATTENUATOR: This three position rotary switch controls the output level of the inter­nal high frequency driver. Use the tip of a flatblade screw­driver to set this switch to the setting which best suits your tastes.
26: FULL RANGE INPUTS: These are the input jacks for the cabinet. Connect one of these jacks to the Speaker ouput of the amplifier; the other jack may be used to carry the amp signal to an extension cabinet if desired.
THE FRONT PANEL:
THE REAR PANEL:
25
26
SERIAL #
HIGH FREQUENCY
ATTENUATOR
FULL RANGE
INPUTS
OFF
47-267-01
–6 0
POWER HANDLING: 150 WATTS
IMPEDANCE: 8 OHMS
MADE IN THE U.S.A. BY SLM ELECTRONICS 1400 FERGUSON AVE. ST. LOUIS, MO 63133
B-15R
B-15R PORTAFLEX
TECHNICAL SPECIFICATIONS:
OUTPUT POWER RATING 100 watts @ 5%THD, 8 ohm load, 120VAC SPEAKER SIZE AND RATING Ampeg Vintage 15”, 8 ohm, 150 watt, 2” voice coil, 56 oz magnet
High Efficiency Piezo Tweeter, 8 ohm, 150 watt (w/network)
CROSSOVER FREQUENCY 3kHz ULTRA HIGH SWITCH 6dB Boost @ 4kHz ULTRA LOW SWITCH 10dB Boost @ 40Hz BASS CONTROL 25dB Range @ 40Hz MID CONTROL 34dB Range @ 200, 400, 900, 1.5k or 2.5kHz TREBLE CONTROL 30dB Range @ 4kHz INPUT IMPEDANCE 0dB: 3M ohms; -15dB: 47k ohms MAX. INPUT SIGNAL LEVEL ACCEPTED 0dB: 1V RMS; -15dB: 5.75V RMS TOTAL SYSTEM GAIN 50dB w/tones flat, Ultra Low and Ultra High off SIGNAL TO NOISE RATIO 90dB POWER REQUIREMENTS 120VAC, 60Hz, 400VA
100VAC, 50/60Hz, 400VA 230VAC, 50/60Hz, 400VA
DIMENSIONS 24”W x 16-1/2”D x 24-1/4”H w/amp flipped inside, w/out caster board
32-7/8” H w/amp flipped out, w/out caster board; 37-1/4” H w/caster board
WEIGHT: 117 lbs
Ampeg continually develops new products, as well as improves existing ones. For this reason,
the specifications and information in this publication are subject to change without notice.
Ampeg is proudly Made in America.
©1998 SLM Electronics, 1400 Ferguson Avenue,
St. Louis, MO 63133 U.S.A.
P/N 47-667-03 • 04/98
IMPORTANT SAFEGUARDS AND PRECAUTIONS:
All Ampeg products are designed for continuous safe operation, as long as common sense is used and steps are taken to help avoid certain problems. Abiding by the following rules can help prevent damage to your amplifier, yourself and others.
The amplifier is equipped with a three-pronged
AC power cord. To reduce the risk of electrical shock, NEVER remove or otherwise attempt to defeat the ground pin of the power cord.
Connect the amplifier ONLY to a properly ground-
ed AC outlet of the proper voltage for your amp.
Avoid sudden temperature extremes, rain and
moisture. Also, avoid sudden and intense impact. (If the unit has been subjected to any of the pre­ceeding abuses, have it looked at by an autho­rized service center.)
NEVER set the amplifier on a support that might
give out under its weight.
Always keep the total speaker impedance at or
above the rated load.
Unplug the amplifier before cleaning it. NEVER
spray liquid cleaners onto the amplifier. Wipe it with a slightly dampened, lint-free cloth to remove dirt and film.
Don’t use the amplifier if it has sustained damage
to the chassis, controls, or power cord. Refer the unit to an authorized service center for inspection.
Amplifiers capable of producing high volume lev-
els are also capable of inflicting permanent hear­ing loss or damage, if the exposure to such levels is prolonged. Such damage is progressive and irreversible!
THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELI­ABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENTACCIDEN­TALDAMAGES OR INJURY, PLEASE FOLLOW THESE PRE­CAUTIONARY GUIDELINES:
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEAT OR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROPERLY GROUNDED AC POWER OUTLET.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOIS­TURE.
CAUTION: NO USER-SERVICE­ABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SER­VICE PERSONNEL.
CAUTION: OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEV­ELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS CAN CAUSE PERMA­NENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PROTEC­TION IS RECOMMENDED IF UNIT IS OPERATED ATHIGH VOLUME.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER.
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL" “ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.” "REFERREZ-VOUS AU MANUAL D'UTILISATION" "UNBEDINGT IN DER BEDIENUNGSANLEITUNG NACHSCHLAGEN"
EXPLANATION OF GRAPHICAL SYMBOLS: EXPLICACION DE SIMBOLOS GRAFICOS: EXPLICATION DES SYMBÔLES GRAPHIQUES:
"DANGEROUS VOLTAGE" “VOLTAJE PELIGROSO” "DANGER HAUTE TENSION" "GEFAHLICHE SPANNUNG"
=
=
PRECAUCION
RIESGO DE CORRIENTAZO
NO ABRA
PRECAUCION PARA DISMINUOIR EL RIESGO DE CORRIENTAZO
NO ABRA LA CUBIERTA
NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO REPARAR
DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS
ATTENTION
RISQUE D'ELECTROCUTION
NE PAS OUVRIR
ATTENTION: POUR REDUIRE D'ELECTROCUTION NE PAS
ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE N'EST REPRABLE
PAR L'UTILISATEUR. POUR TOUTE REPARATION, S'ADRESSER A UN
TECHNICIEN QUALIFIE.
VORSICHT
ELEKTRISCHE SCHLAGGEFAHR
NICHT OFFENEN
VORSICHT: ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGEFAHR NICHT
DEN DECKEL ABENHMEN. INTERNE TEILE KONNEN NICHT VOM
BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM
WARTUNGSPERSONAL ZU UBERLASSEN.
ESTE APARATO HA SIDO DISE­NADO Y CONSTRUIDO PARA PROVEER ANOS DE OPERA­CION SEGURA Y CONFIABLE. PARAPROLONGAR LA VIDA DE ESTAUNIDAD E IMPEDIR DANOS ACCIDENTALES POR FAVOR SIGAESTAS INSTRUC­CIONES PREVENTIVAS:
PRECAUCION: PARA DISMINUIR EL RIESGO DE DESCARGAS ELECTRICAS: (1) NO ABRA LA CUBIERTA, (2) NO ES RECOMENDABLE REMOVER O DESACTIVAR LAPATADEL POLO A TIERRA DEL CABLE DE CORRIENTE, CONECTE COR­RECTAMENTE AUNA TOMA DE CORRIENTE A TIERRA.
ADVERTENCIA: PARA EVITAR DESCARGAS EL ECTRICAS O PELIGRO DE INCENDIO, NO DEJE ESTE APARATO EXPUESTO A LA LLUVIA O HUMEDAD.
PRECAUCION: NO HAY PIEZAS ADENTRO QUE EL USUARIO PUEDE REPARAR. DEJE TODO MANTENIMIENTO A LOS TÉCNI­COS CALIFICADOS.
PRECAUCION: NUESTROS AMPLIFICADORES PUEDEN PRODUCIR NIVELES DE PRE­SION DE SONIDO ALTO. EXPOSICION CONTINUADAA LOS NIVELES DE PRESION DE SONIDO ALTO PUEDE CAUSA DANO PERMANENTE ASU OIDO. ES ACONSEJADO QUE USE PRECAUCION ALUSUARIO Y ES RECOMENDADO PROTEC­CION PARALOS OIDOS SI LA UNIDAD ES OPERADAA VOLU­MEN ALTO.
CET ÉQUIPEMENT AVAIT ÉTÉ INVENTÉ ET ARRANGÉ POUR POURVOIR DES ANNÉES D'USAGE SAUF ET SÛR. POUR PROLONGER LA VIE DE CET APPAREILET POUR EMPÊCHER LES DOMMAGES ET LES TORTS ACCIDENTELS, SUIVEZ LES INSTRUCTIONS DE PRÉCAU­TION.
AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D'ÉLEC­TROCUTION: (1) N’OUVREZ PAS LE CHÂSSIS, (2) NE PAS ESSAYER DE SUPPRIMER LA BROCHE CORRESPONDANT À LA TERRE.
ATTENTION: POUR RÉDUIRE LES RISQUES D'UN FEU OU D'ÉLECTROCUTION, N’EX­POSEZ PAS L'APPAREIL À LA PLUIE OU À LA MOITEUR.
ATTENTION: IL N'Y A PAS D’ÉLÉMENTS RÉPARABLES DANS L'APPAREIL. CONSULTER UN TECHNICIEN QUALIFIÉ POUR LES RÉPARATIONS.
ATTENTION: NOS AMPLIFICA­TEURS SONT CAPABLES DE LA PRODUCTION DES NIVEAUX DE SON D'UNE HAUTE PRESSION. L'EXPOSITION CONTINUE AUX CES NIVEAUX PEUT CAUSER LA SURDITÉ PERMANENTE. LA PRUDENCE EST ADVISÉ À UTIL­ISATEUR ET LA PROTECTION DES OREILLES EST RECOM­MANDÉ SI L'APPAREILEST UTILISÉ À UN HAUT NIVEAU DE VOLUME.
www.ampeg.com