QUICK REFERENCE GUIDE: XG 850 Watt Series Programmable DC Power Supply (firmware v1.09 and below)
The XG is equipped with a rotary Adjust/Enter control to provide a streamlined front panel for faster setup. Set voltage and current quickly and easily using the rotary Adjust/Enter control and the 9-position Mode control. The information provided in this Quick Reference Guide is for basic usage of the front panel and for understanding the menu system. See the other side of this Quick Reference Guide for a map of the front panel menu system. For complete information on the XG, please refer to the XG 850 Watt Series Programmable DC Power Supply Operating Manual (Part number: M370078-01).
2. Constant Voltage Mode LED
3. Model Identification Label
4. Output Voltage Display
5. Constant Current Mode LED
6. Output Current Display
7. Alarm Indicator LED
8. Output On/Off Button
9. AUX On/Off Button
10.l 9-position Mode Control
VOLTS: Voltage Programming AMPS: Current Programming FLD: Foldback PRT: Protection SAV: Save User Setting Memory Locations RCL: Recall User Setting Memory Locations CAP: Current Analog Programming VAP: Voltage Analog Programming PGM: Programming
XG Front Panel Controls, Displays, and Indicators XG Rotary Adjust/Enter Control
General Procedures for Setting Up Features
To select a mode, rotate the 9-position Mode control to the desired mode.
To select the feature or setting, turn the rotary Adjust/Enter control to scroll through the different available settings of that mode.
The settings appear on the output display.
Press the rotary Adjust/Enter control to select the feature or setting.
Set each value using the rotary Adjust/Enter control. When the value has been selected, press the Adjust/Enter control to commit the
updated value.

Setting the Output Voltage and Current Limit Using Tracking Mode

To access the tracking mode where new values take effect as the rotary Adjust/Enter control is turned:
1. Select VOLTS or AMPS on the 9-position Mode control. The set point will blink and the unit will be in coarse tracking mode.
When VOLTS mode is selected, the voltage set point will blink in the output voltage display.
When AMPS mode is selected, the current set point will blink in the output current display.
2. Use the rotary Adjust/Enter control to adjust the set point.
3. Press the Adjust/Enter control to use fine adjust tracking mode. The set point blinks faster when the unit is in fine tracking mode.
4. Use the rotary Adjust/Enter control to fine tune the set point.
5. Once the set point has been selected, press the Adjust/Enter control to exit tracking.
Part Number M370078-04 Rev D January 2009 © 2007-2009 AMETEK Programmable Power, Inc. All rights reserved. www.programmablepower.com
Front Panel Menu System (firmware v1.09 and below) Front Panel Display Messages
y
y
g
g
r
r
)
)
y
r
)
y
g
g
g
VOL
CUR
FLD
PRT
SAV
RCL
CAP
VAP
PGM
Coarse CurrentTracking
CV CC
None
OVP UVP
Overheat Protection
Shutdown Logic
Select Preset
Select Preset
Off
Voltage Isolated
Voltage Non-Isolated
Resistive Isolated
Resistive Non-Isolated
Off
Voltage Isolated
Voltage Non-Isolated
Resistive Isolated
Resistive Non-Isolated
USB LAN
GPIB RS-232 RS-485
Slave Address (1-30)
Local Lock
Fold Delay Fold Delay
OVP CoarseAdjust OVP FineAdjust UVP CoarseAdjust UVP Fine Adjust
On/Off
1/0
Current APG Level Current APG Level Current APG Level Current APG Level
VoltageAPG Level VoltageAPG Level VoltageAPG Level
VoltageAPG Level
Address (1-30) Address (1-30) Address (1-30)
Data Rate Data Rate
On/Off
Coarse Volt Pre-SetCoarse Volt Tracking
Coarse Current Pre-Set
Legend:
Press rotaryAdjust/Enter control
when no modification of the tracking value has been made.
Press rotaryAdjust/Enter control
Rotate rotaryAdjust/Enter control
Address (1-30) Address (1-30)
Fine Volt Pre-SetFine Volt Tracking
Fine Current Pre-SetFine Current Tracking
Mode Control State
Setting/Value
0 1 AnPR AS AvAS CAPr CLr CC COn7 CU CRPC CrPU CShr Curr CUrrShAr deLa FOLD FLA FNPC FNPU FLd gpib HbPS In H rS LE C LE U Loc LOCL OCP O7P OUP OvPF OUPC OU7P POL PRO PSU r IS rCL RE rnIs SAFE Sd sLa
S rS U Is UN Is UUP UUPF UAPr UOL
Negative Polarit Positive Polarit Analog Programmin Power On Autostart Auxiliary Autostart Current Analog Programmin Clea Constant Current Controlle Constant Voltage Coarse Current Pre-set Mode Coarse Voltage Pre-set Mode Current Share (same as CUrrShAr Current Current Share (same as CShr Fold Dela Foldback protection triggered Flash Fine Current Pre-set Mode Fine Voltage Pre-set Mode Setting up Foldback trigge GPIB Interface Data rate (Kbps Interlock Hard Reset Current APG Level Voltage APG Level Lock Local Over Current Protection Over Temperature Protection Over Voltage Protection Over Voltage Protection fine adjustment OVP Calibration Output Protection Polarit Protection mode Power Supply Unit Isolated Resistive Analog Programmin Recall User Setting Memory Locations Remote Programming/Interface Non-Isolated Resistive Analog Safe Shutdown Slave Remote Interface Soft Reset Isolated Analog Voltage Programmin Non-Isolated Analog Voltage Under Voltage Protection Coarse Under Voltage Protection Fine Adjustment Voltage Analog Programmin Voltage