Ametek mAcal Specifications

signal
»
Sources and measures current
Allows for calibration of transmitters in a two­wire loop
»
Stable source
Internal 24 VDC supply for consistent loop power
»
High resolution
Read to 0.001 mA in the measurement mode
»
% of full scale reading
Displays a percentage to provide for easy analysis of results
milliAmp Calibrator
mAcal
»
Timesaving features
Fast one-key-one-function access to the features such as the step function or loop supply power
»
Large display
Includes large numbers for unit reading, a percentage display, and dedicated icons for calibrator status including a low battery indicator
»
Traceable calibration
For your confidence, the unit is supplied with a calibration certificate that is fully traceable to a national standards lab such as NIST or NPL
»
Complete marine program
Part of a complete program of marine approved temperature, pressure and signal calibrators; including temperature sensors
ISO 9001 Manufacturer
The mAcal milliAmp Calibrator is an economical and easy-to-use calibra­tion device for sourcing and measuring mA signals.
The instrument is designed specifically for 2-wire transmitter loops with 4 to 20 mA signals and it is delivered with traceable certification.
The display also indicates error codes. Visual warnings are displayed for loop mismatch, reverse polarity and over range. And is also equipped with a user adjustable automatic shut-off feature that prevents accidental battery discharge when the unit is not in use. A built-in, permanent fuse eliminates the need to replace the fuse in the case of overloads: no need to return the unit to the factory to reset or replace the fuse.
The mAcal provides loop power in the range of 0 to 45 VDC and the instrument is designed to generate a stable 24 VDC supply for the loop. The mAcal also reduces the time and complexity often associated with loop calibration. The instrument features special fixed steps for perform­ing linear and flow transmitter or valve positioner calibrations. The instru­ment has seven different built-in current values and the user may choose between manual or automatic steps with 10 or 30 seconds between steps. You can perform an entire test by placing the mAcal in the pro­cess loop and take readings from the control room.
Specification Sheet, SS-MACAL
PWR
Switch between external and internal loop power supply EXT. (the +24 VDC of the current loop is generated by an external power supply) and INT. (the +24 VDC of the current loop is gen­erated by the mAcal itself).
Mains adapter
Connection to mains adapter. 6 VDC, 230 mA.
Note : The mains adapter does not charge rechargeable bat­teries.
ON/OFF
Switching instrument on/off.
Auto shut-off to extend battery life (user programmable).
mA/% / setup
Alternating between readout in mA and %. If the key is held down for more than 2 sec., a change to SETUP takes place. Under SETUP this key is used to select next parameter.
Connection
Connection of + test lead
Connection
Connection of - test lead
Display
Shows numerical value in mA, %, V or sec., and for readout of error codes etc.
FUNC
This key allows for changing functions between SOURCE mA, MEASURE mA and MEASURE Volt function.
Step
The STEP function is acti­vated or de-activated.
Up arrow
Functions to increase entered values or to scroll up.
Auto
AUTO ramp or AUTO-STEP function is started or stopped.
Down arrow
Functions to decrease entered values or to scroll down.
JOFRA mAcal in softcase
The mAcal calibrator is available separately and are supplied in a handy softcase that allows for complete operation of the unit while in the case. The convenient internal arrangement offers you the space to store test leads.