Ametek IPI015G, IPI030C, IPI100A, IPI100C, IPI300C Data sheet

...
pressure
Industrial Pressure Indicator
IPI Mk. II
Intrinsically
» Wide pressure range
IPI015G 1 bar / 15 psi IPI030C 2 bar / 30 psi IPI100A 7 bar absolute / 100 psi IPI100C 7 bar / 100 psi IPI300C 21 bar / 300 psi IPI500C 35 bar / 500 psi IPI01KG 70 bar / 1,000 psi IPI02KG 140 bar / 2,000 psi IPI03KG 200 bar / 3,000 psi IPI05KG 350 bar / 5,000 psi IPI10KG 700 bar / 10,000 psi
» High accuracy
±0.05% of F.S. for positive pressure. Vacuum calibration to 35 bar / 300 psi. Compound ranges are indicated with “C” in type number
» A true field indicator
Lightweight and portable with full tempera­ture compensation, long battery life and large display for easy visibility
» IPILOG Data logging
Comprehensive data logging facilities. Log pressure and temperature data, triggered by time or threshold (option)
safe
» Complete marine program
Part of a complete program of marine approved temperature, pressure and signal calibrators; including temperature sensors
» ATEX and CSA certification
The IPI Indicator is ATEX and CSA certified and designed for use in potentially explosive environments
ISO 9001 Manufacturer
Specification Sheet SS-IPI Mk. II
The JOFRA IPI Mk. II brings together the ease of an analog gauge with the accuracy and easy-to-read display of a digital calibrator.
IPI Mk. II is ATEX and CSA certified for use in potentially explosive envi­ronments such as oil refineries, chemical plants and offshore platforms, where flammable gases are used or stored.
This series is designed to meet your pressure measurement application needs and make your work easier. The IPI offers 18 different pressure units, long battery life, high accuracy and serial communications. The accuracy of the IPI Mk. II rivals high-end pressure calibrators and is tem­perature compensated for workshop use or in process applications.
Combined with IPILOG, you get a high-performance solution for pres­sure data logging applications. Whether you need to log data on one IPI or many, IPILOG is easy to use and is a low-cost application that can handle all of your requirements. IPILOG configures the gauge to oper­ate in ad-hoc mode (field configuration) or download mode (computer configuration) for complete flexibility in configuring your data logging applications.
The IPI Mk. II is available as an indicator or in one of six test-ready sys­tems that are complete and equipped to meet your pressure measuring or testing needs.
Easy setup
Setup of the IPI Mk. II is fast and straight forward, through a menu-driven display. With minimal text and intuitive func­tions, the unit is simple enough to be used anywhere in the world, without the need for multilingual displays.
The CONFIG key is used in conjunction with the and functions above the ZERO and MAX/MIN keys to select and change different functions.
You can set one of 20 engineering units, change the auto­shutoff function setting, display the actual battery volt­age, display the actual temperature (in °C or °F), turn the dampening on or off, change the sample rate and set the Tare value. In addition to the 20 available engineering units on the IPI Mk. II, you can create your own unit to meet your measurement needs.
Easy-to-read display
The large, 5 1/2 digit, 0.65 in (1.65 cm) character display is large and easy-to-read, even from a distance. Icons indicate battery life and engineering units and a bar graph shows the percentage of scale reading. All of this information can be read in low light with the use of the backlight.
Auto-shutoff
The IPI Mk. II is delivered with the auto-shutoff active and set to 30 minutes. This feature can be reduced to 1 minute in 1 minute increments. This can be completely turned off in cases where a constant reading is necessary.
Serial communications
The IPI Mk. II has a serial port that is accessible though the back of the case. This feature uses standard ASCII com­mands to allow for extraction of data from the IPI Mk. II while taking readings. This requires the optional serial cable.
Hazardous location information / approvals
The standard in the European Union has been set with the 9/94/EC Directive, commonly called ATEX (“Atmosphères Explosibles,” French for explosive atmospheres).
The JOFRA IPI Mk. II is ATEX approved by KEMA as com­plying with the Essential Health and Safety Requirements related to the design and construction of equipment and protective systems intended for use in potentially explo­sive atmospheres given in Annex II in the directive, and with the following rating: II 3 G EEx nA IIB T6 (Ta=–10°C to +55°C).
The IPI Mk. II is also certified by CSA as conform­ing to relevant Canadian and USA standards with the following rating: Class 1, Div. 2, Groups A-D
See the definitions regarding hazardous locations in NFPA 70, Article 500 or CSA C22.1 Section 18. NFPA 70, Article 500 and CSA C22.1 Section 18.
Field recalibration
The IPI Mk. II does not need to be returned to the factory for calibration. If you have a reliable and accurate pressure reference or a local laboratory, you may recalibrate the unit locally. This feature is password protected.
Sampling rate
The IPI Mk. II sampling rate is user selectable. If you want to capture fast system transients, the unit can take a read­ing 10 times per second. Conversely, you may want to conserve battery life and only need periodic samples. This works well for in process and panel mounted applications. You can also choose the accepted instrument sampling rate of three samples per second.
Damping adjustment
The damping function can be turned on or off. This allows for readings to be integrated, which accounts for momentary changes such as those from pulsing sources.
Tare
Beyond zeroing the unit, you may have to account for residual pressure. The Tare feature allows you to take care of that error and prevent the manual calculation of the dif­ference. This can be used in combination with the custom engineering units to make the level measurements easier.
Temperature display and compensation
Because the IPI Mk. II is designed for in-process tasks, tem­perature compensation is included to make the job easier. This allows the unit to maintain accuracy over the measure­ment range. The measured temperature may be checked from the keypad.
2 www.jofra.com Industrial Pressure Indicator • IPI Mk. II
JOFRACAL Calibration Software
JOFRACAL ensures easy calibration of RTD´s, thermocouples, transmit-
ters, thermo switches, pressure gauges and pressure switches. JOFRACAL can be used with all JOFRA calibration instruments. When used with ASM-800 signal multi scanner, JOFRACAL can perform a simultaneous semi-automatic calibration on up to 24 pres­sure and/or temperature devices under test in any combi­nation.
JOFRACAL software controls the complete calibration procedure, stores the results and provides a calibration audit trail through hard-copy certificates. All calibration data is stored for each sensor to monitor drift and optimize recalibration intervals. A scheduler feature allows planning of future calibrations.
IPILOG Data logging software (Order Number 128494)
IPILOG is a high-performance solution for pressure data logging applications. Whether you need to log data from a single IPI Mk.II or many, IPILOG is a cost-effective applica­tion that can handle all your needs.
Using the download mode allows a wide range of configu­ration settings, including:
• Multiple interval selection options from 1 sec to 1 hour
• Data logging runs can range from a few seconds to several weeks
• Ambient temperature can be logged along with pres­sure for leak testing applications
• Four types of data capture mode allow you to log either all data or only the points you’re interested in
o Continuous (log all data at predefined intervals)
o Data high (log data only when it rises above a preset
value)
o Data low (log data only when it falls below a preset value)
o Delta trip (for detecting noise or transients in the pressure
signal)
• Number of data points to record (maximum of 8500)
• Type of data .Interval end .Average .Minimum .Maxi­mum .Median Average/Minimum/Maximum
When set to demand mode, you can easily set up and start data logging in the field using the keypad. The IPI Mk. II is very flexible and supports multiple data sets that can be mixed between demand mode and download mode. Con­nection is done via a RS232 / USB converter and allows IPILOG to retrieve the data and store it on your computer in a variety of formats:
• Plain ASCII text (.TXT)
• Comma delimited text (.CSV)
• Microsoft™ Excel™ Spreadsheet (
• Microsoft Excel Spreadsheet with template formatting (sample templates come with the IPILOG application and you can create your own to meet your specific requirements)
The data you get is reliable, accurate and easy to acquire and manage for a variety of applications, for example:
• Hydrostatic pressure testing
• Leak detection
• Transient pressure spike detection
• Well head pressure monitoring
• District heating systems
• Gas distribution
• Fresh water supply
• Wastewater treatment
• And many others…
requires Excel 2002 or later)
IPILOG delivery (Order Number 128494):
• CD with IPILOG program
• Spreadsheet templates
• Drivers and manual.
• RS232 cable, and USB to RS232 converter
www.jofra.com 3IPI Mk. II • Industrial Pressure Indicator
FUNCTIONAL SPECIFICATIONS
Pressure; compound ranges
bar .....................................................-0.82 to 2, 7, 21 or 35
psi .............................................. -12 to 30, 100, 300 or 500
Pressure; gauge ranges
bar ..................................... 0 to 1, 70, 140, 200, 350 or 700
psi ............................ 0 to 12, 1,000, 2,000, 5,000 or 10,000
Pressure; absolute ranges
bara ........................................................................0.07 to 7
psia .......................................................................... 1 to 100
Engineering units
User defined ................................... One user-definable unit
User selectable ........................................................ 20 units
(PSI, Bar, kg/cm2, inH2O (4°C, 20°C or 60°F), ftH2O (4°C, 20°C or 60°F), mmH2O (4°C and 20°C), cmH2O (4°C and 20°C), mH2O (4°C and 20°C), KPa, mBAR, inHg, mmHg, Torr)
Not all units are available in all ranges.
Pressure accuracy
Pressure ........................................................... ±0.05% F.S.
Full temperature compensation ......0 to 50°C / 32 to 122°F
Vacuum (100, 300, 500 psi indicator/
7, 21, 35 bar indicator) ...................... ±0.25% F.S.
Vacuum (30 psi indicator/2 bar indicator) .......... ±0.1% F.S.
F.S. (full scale) is the numerical value of the positive pressure range. Accuracy includes hysteresis, nonlinearity, repeatability, reference standard uncertainty and 1 year typical long-term sta­bility operated inside the rated temperature span and pressure range. Requiring frequently zeroing (Gauge/diff.) or entering of reference pressure (Absolute). Pressure accuracy ambient temp. (0 to 50°C / 32 to 122°F).
Serial communication interface
Connector .......................................................... Stereo jack
Serial ......... 0-3 VDC, 9600 baud, 8 data, no parity, 1 stop
Protocol ..................................... ASCll command language
Media compatibility
Liquid and gas compatible with 316 stainless steel.
Environmetal
Storage temperature ....................-20 to 70°C / -4 to 158°F
Operating temperature ...............-10 to 55°C / -14 to 131°F
Pressure connection
All ranges .....................................................1/4” NPT male
Adapter to 1/4” BSP male are included as standard.
Pressure overload
1 to 35 bar / 15 to 500 psi…….. ............................ 3X range
70 to 350 bar / 1,000 to 5,000 psi ........................ 2X range
700 bar / 10,000 psi …………… ......................... 1.5X range
Overload alarm ………………………………… OL on display Overload alarm range ……………………… …… 1.2X range
Display
Display .......................................................... Backlight, blue
Display resolution .......................... 5 digit floating decimal
Bar graph........................................ 20 segment, 0 to 100%
Display indicators ..............................Engineering units icon
...................................................Low battery indication icon
.............................. Battery life indication utilizing bar graph
............................................. Measured temperature display
Display update ........................................ Twice per second
Power supply
Battery .......................................................... (3) AA Alkaline
Battery life ......... 1500 operational hours without backlight
Battery life ......... 2000 operational hours without backlight
..............................................................at low sampling rate
Battery life .................150 operational hours with backlight
Low battery indicator .............................................at 3 VDC
Instrument dimensions
Indicator LxWxH ..... 125 x 111 x 38 mm / 4.9 x 4.4 x 1.5 in
Indicator weight (including battery) ................1.6 lb / 0.7 kg
Input port .......................................................1/4” NPT Male
Shipping dimensions
Indicator LxWxH ... 250 x 160 x 100 mm / 9.8 x 6.3 x 3.9 in
Indicator weight ..............................................1.8 lb / 0.8 kg
Instrument case
Rating ............................................................. NEMA 4/IP65
Approvals - IPI Mk. II system
CE Conformity ....................................................... EN61326
...................................EN60079-0: 2009, EN60079-15:2005
Ex approvals - IPI Mk. II indicator only
CSA ..........................................Class 1, Div. 2, Groups A-D
ATEX .................... II 3 G EEx nA IIB T6 (Ta=–10°C... +55°C)
4 www.jofra.com Industrial Pressure Indicator • IPI Mk. II
JOFRA IPI Mk. II PRESSURE RANGES
This table shows the resolutions that can be obtained by the IPI Mk. II throughout all engineering units.
Resolution obtained by the IPI indicator
IPI30C Vacuum to 30 psi Vacuum to 2 bar
IPI100A / IPI100C Vacuum to 100 psi Vacuum to 7 bar
IPI300C Vacuum to 300 psi Vacuum to 21 bar
IPI500C Vacuum to 500 psi Vacuum to 35 bar
Imperial ranges
psi -12.000 30.000 -12.00 100.00 -12.00 300.00 -12.00 500.00
inH
O@4°C -332.17 830.42 -332.2 2768.1 -332.2 8304.2 -332 13840
2
inH
O@20°C -332.76 831.89 -332.7 2773.0 -332.7 8318.9 -333 13865
2
inH
O@60°F -332.50 831.24 -332.5 2770.8 -332.5 8312.4 -332 13854
2
ftH
O@4°C -27.681 69.202 -27.68 230.67 -27.68 692.02 -27.7 1153.4
2
ftH
O@20°C -27.730 69.324 -27.73 231.08 -27.73 693.24 -27.7 1155.4
2
ftH
O@60°C -27.708 69.270 -27.71 230.90 -27.71 692.70 -27.7 1154.5
2
inHg@0°C -24.432 61.081 -24.43 203.60 -24.43 610.81 -24.4 1018.0
Torr -620.6 1551.5 -620.6 5171.5 -620 15514 -621 25858
Metric ranges
bar -0.8300 2.0000 -0.8300 7.0000 -0.8300 21.000 -0.830 35.000
mbar -830.0 2000.0 -830.0 7000.0 -830 21000 -830 35000
kPa -83.00 200.00 -83.00 700.00 -83.0 2100.0 -83.0 3500.0
2
kg/cm
cmH
O@4°C -846.4 2039.5 -846.4 7138.2 -846 21415 -846 35691
2
cmH
O@20°C -847.9 2043.1 -847.9 7150.8 -847 21452 -848 35754
2
mH
O@4°C -8.464 20.395 -8.464 71.382 -8.46 214.15 -8.46 356.91
2
mH
O@20°C -8.479 20.431 -8.479 71.508 -8.48 214.52 -8.48 357.54
2
-0.8464 2.0394 -0.8464 7.1380 -0.846 21.414 -0.846 35.690
mmHg@0°C -622.6 1500.1 -622.6 5250.4 -622 15751 -623 26252
Resolution obtained by the IPI indicator
IPI015G 0 to 15 psi 0 to 1 bar
Imperial ranges
psi 15.000 1000.0 2000.0 3000.0 5000.0 10000
inH
O@4°C 415.21 27681 55361 83042 N/A N/A
2
inH
O@20°C 415.95 27730 55459 83189 N/A N/A
2
inH
O@60°F 415.62 27708 55416 83124 N/A N/A
2
ftH
O@4°C 34.601 2306.7 4613.5 6920.2 11534 23067
2
ftH
O@20°C 34.662 2310.8 4621.6 6932.4 11554 23108
2
ftH
O@60°C 34.635 2309.0 4618.0 6927.0 11545 23090
2
inHg@0°C 30.540 2036.0 4072.1 6108.1 10180 20360
Torr 775.73 51715 N/A N/A N/A N/A
Metric ranges
bar 1.0000 70.000 140.00 200.00 350.00 700.00
mbar 1000.0 70000 N/A N/A N/A N/A
kPa 100.00 7000.0 14000 20000 35000 70000
2
kg/cm
cmH
O@4°C 1019.7 71382 N/A N/A N/A N/A
2
cmH
O@20°C 1021.5 71508 N/A N/A N/A N/A
2
mH
O@4°C 10.197 713.82 1427.6 2039.5 3569.1 7138.2
2
mH
O@20°C 10.215 715.08 1430.2 2043.1 3575.4 7150.8
2
1.0197 71.380 142.76 203.94 356.90 713.80
mmHg@0°C 750.06 52504 N/A N/A N/A N/A
IPI01KG 0 to 1,000 psi 0 to 70 bar
IPI02KG 0 to 2,000 psi 0 to 140 bar
IPI03KG 0 to 3,000 psi 0 to 200 bar
IPI05KG 0 to 5,000 psi 0 to 350 bar
IPI10KG 0 to 10,000 psi 0 to 700 bar
www.jofra.com 5IPI Mk. II • Industrial Pressure Indicator
IPI Mk. II, System A
• T-960, 0 to 2 bar (0 to 30 psi)
• T-970, 0 to 40 bar (0 to 580 psi)
This system includes the IPI Mk. II together with one pneumatic hand pump: T-960 or T-970. System A is an easy-to-use single-hand operated pressure system.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
A special quick connector between the pump and the unit makes it possible to separate the system in seconds and swivel the calibrator for easy viewing.
The IPI Mk. II used in System A is delivered calibrated in both pressure and vacuum.
T-960 and T-970 pump for system A
Both the T-960 and T-970 feature an extended range vol­ume adjuster for precise control of the pump pressure and a comfortable pistol grip handle.
Test medium.....................................................................Air
Operation .................................................................. Scissor
“O”-rings ..................................................................Buna-N
Wetted parts ..........Aluminum, brass, stainless steel, nylon,
Nylatron GS
Connection to test object..................Hose 0.6 m/24 in with
1/4” BSP and NPT female terminations
Size ................................ 21.6x12.1x6.2 cm / 8.5x4.8x2.4 in
Total system weight .....................................5.5 kg / 12.2 lb
Accessories
• Pressure hose for T-960/970, 0.5, 1.0, 2.0 or 5.0 meter
• Set of BSP female fittings, Teflon tape, packings
• Set of NPT female fittings, Teflon tape, packings
• Connections for APM-H pressure modules
• Fitting for APM-H pressure module
IPI Mk. II, System B
• T-965, -0.65 to 2 bar (30 psi)
• T-975, -0.91 to 40 bar (580 psi)
This system includes the dual func­tion pneumatic hand pump: T-965 or T-975 that can calibrate both vacuum and pressure applications by the push of one button.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
A special quick connector between the pump and the unit makes it possible to separate the system in seconds and swivel the calibrator for easy viewing.
T-965 and T-975 pump for system B
Both the T-965 and T-975 feature vacuum as well as pres­sure generation. A quick switch (valve) makes it easy to move between the two. A built-in release valve, volume adjuster for fine adjustment and dual pressure output enable a safe and simple operation. The unit offers both metric and imperial threads on the reference connection and the hose.
Test medium.....................................................................Air
Operation .................................................................. Scissor
“O”-rings ..................................................................Buna-N
Wetted parts ..........Aluminum, brass, stainless steel, nylon,
Nylatron GS
Connection to test object..................Hose 0.6 m/24 in with
1/4” BSP and NPT female terminations
Size ................................ 21.6x12.1x6.2 cm / 8.5x4.8x2.4 in
Total system weight .....................................5.5 kg / 12.2 lb
Accessories
• Pressure hose for T-960/970, 0.5, 1.0, 2.0 or 5.0 meter
• Set of BSP female fittings, Teflon tape, packings
• Set of NPT female fittings, Teflon tape, packings
• Connections for APM-H pressure modules
• Fitting for APM-H pressure module
IPI Mk. II, System C
• T-620, 0 to 200 bar (3,000 psi)
• T-620H, 0 to 350 bar (5,000 psi)
This system consists of an IPI Mk. II together with a hydraulic, high pres­sure hand pump T-620 or T-620H featuring an oil reservoir to prime the system.
System C is an easy-to-use single-hand operated cali­bration system. The system includes release valve and volume adjuster for fine adjustment to enable a safe and simple operation of the pump.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
Easy and fast connection between pump and calibrator makes it easy to use the pressure calibrator separately for other pressure test jobs.
T-620 and T-620H pump for system C
The T-620 and T-620H are specially designed for high­pressure applications. They have a built-in reservoir, vent valve, and volume adjuster for fine adjustment. The pump has a dual pressure output - one for the test object and one for the IPI Mk. II.
Test medium.....................................................................Oil
Operation .................................................................. Scissor
Reservoir capacity ....................................200 ml / 0.42 pint
Operation ..............................................................Pistol-grip
“O”-rings ..................................................................Buna-N
Wetted parts ..........Aluminum, brass, stainless steel, Lexan
Connection to test object..................Hose 0.6 m/24 in with
1/4” BSP and NPT female terminations
Size ................................ 21.6x12.1x6.2 cm / 8.5x4.8x2.4 in
Total system weight .....................................5.5 kg / 12.2 lb
Accessories
• Pressure hose for T-620/T-620H pumps
• 1 m or 2 m hose with 1/4” BSP female termination,
Max. pressure 350 bar (5,000 psi)
• AAA oil in qt. or gal. can
• Connections for APM-H pressure module
• Fitting 1/8” NPT male to 1/4” NPT male
• Fitting 1/8” NPT male to 1/8” NPT male
6 www.jofra.com Industrial Pressure Indicator • IPI Mk. II
IPI Mk. II, System D
• DOX/0 to 350 bar (5,000 psi) oil
• DWX/0 to 350 bar (5,000 psi) water
This system consists of an IPI Mk. II with a hydraulic, high-pressure screw pump.
The system is easy-to-use; place the pump on a flat sur­face and turn the handle to generate pressure. The system includes a 4-connection manifold for the test device, and optional fine adjustment volume adjuster, and reservoir for extra oil or water.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
Spindle pump for system D
The spindle pump is designed for easy generation of high pressure. Fine adjustment, extra fine volume adjuster, liquid reservoir, and fittings are optional. Spindle pumps may be delivered for 2 different test media: hydraulic oil or water.
Test medium.......................................... Hydraulic oil, water
Operation ........................................................Spindle pump
Reservoir capacity ....................................250 ml / 0.53 pint
“O”-rings ..................................................................Buna-N
Wetted parts ..................... Aluminum, brass, stainless steel
Connection to test object.................... 4 x 1/4” BSP female
Size ............................ 36.6x19.5x10.5 cm / 14.4x7.7x4.1 in
Total system weight ......................................11 kg / 24.3 lb
Accessories
• Extra fine adjuster, volume adjuster
• Reservoir set with seals, valve and bonded seal
• 1 or 2 m pressure hose (Max. 350 bar / 5,000 psi)
• 1.5 or 5 m pressure hose (Max. 700 bar/10,000psi)1
• Extension tube 120 mm (Max. 350 bar/5.000 psi)1
• Quick connector set, female 1/4” BSP to 1/4” BSP
• Fitting 1/4” BSP male to 1/4” NPT female
• Fitting 1/8” NPT male to 1/4” NPT male
• Fitting 1/8” NPT male to 1/4” BSP female
1
1/4” BSP female to 1/4” BSP male
1
IPI Mk. II, System E
• EXX/0 to 700 bar (10,000 psi)
This system consists of an IPI Mk. II together with a rugged, hydraulic, high pressure pump.
The system is easy-to-use and the hydraulic pump makes it very easy to prime the system. The system includes a 4-connection output manifold for two test devices and a fine adjustment volume adjuster is standard.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
Easy and fast connection between pump and calibrator makes it easy to use the pressure calibrator separately for other pressure test jobs.
High pressure hydraulic oil pump for system E
The pump is designed for high-pressure applications.
Test medium.....................................................................Oil
Operation ............................................................ Jack pump
Reservoir capacity .........................................500 ml / 1 pint
“O”-rings ..................................................................Buna-N
Wetted parts ..................... Aluminum, brass, stainless steel
Connection to test object.................... 4 x 1/4” BSP female
Size ............................ 36.5x20.0x14.2 cm / 14.4x7.9x5.6 in
Total system weight ......................................13 kg / 28.7 lb
Accessories
• 1.5 or 5 m pressure hose, (Max. 700 bar/10,000 psi)
• Quick connector set, female 1/4”BSP to 1/4” BSP
• Connections for APM-H
• Fitting 1/4” BSP male to 1/4” NPT female
• Fitting 1/8” NPT male to 1/4” NPT male
• Fitting 1/8” NPT male to 1/4” BSP female for
APM-H pressure module with Jack-pump alone
1
1/4” BSP female to 1/4” BSP male
1
IPI Mk. II, System F
• FOx/0 to 700 bar (10,000 psi) oil
• FWx/0 to 700 bar (10,000 psi) water
System F is an easy-to-use calibration system. The hydraulic pump makes it very easy to prime the system and contains 1.23 l of liquid.
The system includes a dual pressure output manifold for two test devices, a volume adjuster for fine adjustment and, dual volume control for rapid pressure.
The system comes in a carrying case with cut-outs for fit­tings, hose, Teflon tape, and the complete assembled unit.
The pump is designed for high-pressure applications up to 15,000 psi (1,000 bar). The system can be ordered with either oil or a water/alcohol mixture as pressure medium. There are three available seal packages for the system: Buna-N, Viton®, and EPT.
Hydraulic pump for system F
The Type T pump features a dual pressure output mani­fold, volume adjuster (up to 200 bar / 2,900 psi), relief valve and dual volume control for rapid pressure increase at lower pressures and easier pumping at higher pressures.
Test medium.......................................... Hydraulic oil, water
Operation ............................................................ Jack pump
Reservoir capacity ........................................1.23 l / 2.6 pint
“O”-rings ...........Buna-N (standard) or EPT/Viton (Optional)
Wetted parts ...................................... Stainless steel, Monel
Connection to test object....1/4” and 1/2” BSP teminations
1/4” and 1/2” PT female terminations
Size ................................ 79.4x22.9x50.8 cm / 31.3x9x20 in
Total system weight .................................... 18 kg / 39.7 lbs
Accessories
• 1.5 or 5 m pressure hose (Max. 700 bar/10,000 psi)
1
• AAA oil in qt. or gal. can
• Connections for APM-H pressure modules
• Union Body 1/4” NPT female for manifold pump T
• Fitting 1/8” NPT male to 1/4” NPT male
1
1/4” BSP female to 1/4” BSP male
www.jofra.com 7IPI Mk. II • Industrial Pressure Indicator
ORDERING INFORMATION
Order number Description
IPI Type
Mk. II Model
NONE No calibrator, pressure system only
Calibrated pressure range
015G 0 to 1 barg / 15 psig
030C -0.82 to 2 barg / 30 psig
100A 0.07 to 7 bara / 100 psia
100C -0.82 to 7 barg / 100 psig
300C -0.82 to 21 barg / 300 psig
500C -0.82 to 35 barg / 500 psig
01KG 0 to 70 barg / 1,000 psig
02KG 0 to 140 barg / 2,000 psig
03KG 0 to 200 barg / 3,000 psig
05KG 0 to 350 barg / 5,000 psig
10KG 0 to 700 barg / 10,000 psig
Calibration certificate
G NIST traceable calibration certificate
Accessories (Optional)
B Battery pack, 3 x rechargeable AA batteries and
multi voltage charger
Pressure system
IND Calibrator only
AXX Syst. A, T-960 pump, up to 2 bar/30 psi
AHX Syst. A, T-970 pump, up to 35 bar/500 psi
BXX Syst. B, T-965 pump, up to 2 bar/30 psi
BHX Syst. B, T-975 pump, up to 35 bar/500 psi
CXX Syst. C, T-620 pump, up to 200 bar/2,900 psi OIL
CHX Syst. C, T-620H pump, up to 350 bar/5,000 psi OIL
DOX Syst. D, 65-P016 pump, up to 350 bar/5,000 psi OIL
DWX Syst. D, 65-P017 pump, up to 350 bar/5,000 psi WATER
EXX Syst. E, 65-P014 pump, up to 700 bar/10,000 psi OIL
FWB Syst. F, T-1 pump, up to 700 bar/10,000 psi WATER/Buna-N
FWV Syst. F, T-1 pump, up to 700 bar/10,000 psi WATER/VITON
FWE Syst. F, T-1 pump, up to 700 bar/10,000 psi WATER/EPT
FOB Syst. F, T-1 pump, up to 700 bar/10,000 psi OIL
FOV Syst. F, T-1 pump, up to 700 bar/10,000 psi OIL/VITON
FOE Syst. F, T-1 pump, up to 700 bar/10,000 psi OIL/EPT
Sample order number
IPI Mk. II 300C G B BXX IPI Mk. II, -0.82 to 21 bar / 300 psi, NIST traceable certificate,
rechargeable battery pack, pressure system B, alu case with T-965 pump and accessories
STANDARD DELIVERY
IPI Mk. II indicator
Calibration certification performance traceable to NIST
Three AA batteries
Adapter to 1/4” BSP male
User manual
Protective rubber boot
A business unit of AMETEK Measurement & Calibration
AMETEK Test & Calibration Instruments
Technologies Division offering the following industry
leading brands for test and calibration instrumentation.
JOFRA Calibration Instruments
Temperature Calibrators
Portable dry-block calibrators, precision thermometers
and liquid baths. Temperature ranges from
-90°C(-130°F) to 1205°C(2200°F). Temperature sensors for industrial and marine use.
Pressure Calibrators
Convenient electronic systems ranging from -25 mbar to 1000 bar - fully temperature -compensated for problem-
free and accurate field use.
Signal Instruments
Process signal measurement and simulation for easy
control loop calibration and measurement tasks.
M&G Pressure Testers & Pumps
Pneumatic floating-ball or hydraulic piston dead weight
testers with accuracies to 0.015% of reading. Pressure
generators delivering up to 1,000 bar.
Lloyd Instruments
Materials testing machines and software from Lloyd
Instruments guarantees expert materials testing
solutions. The comprehensive program also cover s
Texture Analysers to perform rapid, general food testing
and detailed texture analysis on a diverse range of foods
and cosmetics.
Davenport Polymer Test Equipment
Allows measurement and characterization of moisture-
sensitive PET polymers and polymer density.
Chatillon Force Measurement
The hand held force gauges and motorized testers
have earned their reputation for quality, reliability and
accuracy and they represent the de facto standard for
force measurement.
Newage Testing Instruments
Hardness testers, durometers, optical systems and
software for data acquisition and analysis.
UK
AMETEK Calibration Instruments
Tel +44 (0)1243 833 302 jofra@ametek.co.uk
France
AMETEK S.A.S.
Tel +33 (0)1 30 68 89 40 general.lloyd-instruments@ametek.fr
Germany
AMETEK GmbH
Tel +49 (0)2159 9136 510 info.mct-de@ametek.de
Information in this document is subject to change without notice. ©2012, by AMETEK, Inc., www.ametek.com. All rights reserved.
Denmark
AMETEK Denmark
Tel +45 4816 8000 jofra@ametek.com
USA
AMETEK Mansfield & Green Tel +1 (800) 527 9999 cal.info@ametek.com
India
AMETEK Instruments India Pvt Ltd.
Tel +91 22 2836 4750 jofra@ametek.com
8 www.jofra.com
www.jofra.com
Singapore
AMETEK Singapore Pte Ltd
Tel +65 6484 2388 jofra@ametek.com
China
AMETEK Inc. - Shanghai
Tel +86 21 5868 5111
AMETEK Inc. - Beijing
Tel +86 10 8526 2111
AMETEK Inc. - Guangzhou
Tel +86 20 8363 4768 jofra.sales@ametek.com.cn
Pub code SS-IPI Mk. II Issue 1210
Loading...