Ametek HPC550Ex, HPC 552Ex Data sheet

p r e s s u r e
» Ex Safety Certifications
ATEX: II 2 G Ex ia IIB T3 Gb (Ta=-10°C to + 45°C) KEMA 10 ATEX 1068 X IECEx: Ex ia IIB T3 Gb (Ta=-10°C to +45°C) IECEx CSA 10.0013
» Wide pressure range
25 mbar to 700 bar FS (0.35 to 10,000 psi)
» High accuracy
±0.025% of reading +0.01% F.S.
» True field calibrator
Fully temperature compensated
Handheld Pressure Calibrator
HPC550Ex Family
Intrinsically
safe
» Single or dual sensor versions
Chose between HPC550Ex single senror calibrator, or HPC552Ex dual sensor cali­brator. A HPC552Ex might be an alternative to two separate calibrators, saving invest-
ment and cost of ownership
» Full set of intelligent features
Wide selection of useful functions and fea­tures. Damping, leak test, % error calcula­tion, min/max, switch test, etc.
» Thermometer
High accuracy thermometer, Pt100 sensor.
» Intrinsically Safety - Apparatus
- IECEx and EU Ex standards
JOFRA HPC550/552Ex are intended for use in explosively hazardous areas and designed to prevent ignition by electrical,
sparking or heating effects.
ISO 9001 Manufacturer
Specification Sheet SS-HPC550Ex
JOFRA HPC550/552Ex calibrators feature deadweight tester accuracy in a modern digital package.
The HPC550/552Ex can be used in a very broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems. Including potential hazardous areas in Oil, Gas and Chemical industries.
The HPC550/552Ex series has been designed to meet high accuracy pressure calibration applications and faciliate your tasks. HPC550/552Ex offers features such as user configurable information display, 15 different pressure units, transmitter supply, mA input, % error calculation, volt­age measurement, serial communication, and external pressure module capability. The accuracy of the HPC550/552Ex calibrators is specified in % of reading to ensure an even better accuracy and wider applicable pressure range. The HPC is temperature compensated from 0 to 45ºC/32 to 113ºF for on-site operation. It is a truly superior pressure calibrator for laboratory and field use, bringing laboratory accuracy into the field.
The pressure calibrator of choice in potential explosive atmospheres. The intrinsically safe HPC550/552Ex calibrators complies with ATEX / IECEx certifications and are an extension of JOFRA´s well known pressure cali­brator range.
HPC550/552Ex meet the needs of technicians who install, maintain, calibrate and troubleshoot equipment in petro-chemical plants, on oil platforms, in refineries, governmental bodies, commercial organizations and any location subject to the risk of potential explosion hazardous atmospheres.
Clear graphical display
Large backlit graphical display shows current status and mode, 1, 2 or 3 measurement windows, to suit your applications and demands.
Full set of features
Perform semi-automatic pressure switch tests, leak test, % error cal­culation, switch in HART resistor or other calibration tasks through the outstanding functions and features of the HPC550Ex.
Intuitive menu system
Combination of “soft keys” and cursor keypad ensures easy opera­tion.
Temperature measurement
High accuracy temperature measurement port by use of he optional Pt100 sensor. A superb instrument for easy and convenient tempera­ture measurement.
Electrical connections
HPC calibrators are well equipped and include inputs for mA, switches and temperature measurements.
Units
15 different engineering units on pressure measurements.
Zero
To keep high accuracy, a dedicated zero button is available to pro­vide convenient zero before test.
ON / OFF
Auto shut-off to expand battery life time (user programmable).
Pressure connections
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
What is an Ex area?
Ex areas can be known by different names such as “Hazardous Locations”, “Hazardous Areas” “Explosive Atmospheres”, and the like and relate to areas where flammable liquids, vapours, gases or combustible dusts are likely to occur in quantities sufficient to cause a fire or explosion.
The modern day automation of industry has meant an increased need to use equipment in Ex areas. Such equip­ment is termed “Ex equipment”.
What is ATEX?
The ATEX directive consists of two EU directives describ­ing which equipment and work environment is allowed in an environment with an explosive atmosphere.
ATEX derives its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.
Where does ATEX apply? All the 24 member coun­tries of the European Union, plus Norway, Iceland and Liechtenstein, are subject to the directives.
Where do you commonly use Ex equipment?
•Automotiverefuelingstationsorpetrolstations
•Oilrefineries,rigsandprocessingplants
•Chemicalprocessingplants
•Printingindustries,paperandtextiles
•Hospitaloperatingtheatres
•Aircraftrefuelingandhangars
•Surfacecoatingindustries
•Seweragetreatmentplants
•Gaspipelinesanddistributioncenters
•Woodworkingareas
•Sugarrefineries
What is IECEx?
The objective of the IECEx System is to facilitate interna­tional trade in equipment and services for use in explo­sive atmospheres, while maintaining the required level of safety, to offer:
• Internationalconfidenceintheproductassessmentpro-
• HPCExfamilyiscertifiedbyCSA,statingIECExbeing
• MaintainingInternationalConfidenceinequipmentand
cess
the certification of the future for America
services covered by IECEx Certification
2 www.jofra.com Handheld Pressure Calibrator HPC550Ex/552Ex
FUNCTIONAL SPECIFICATIONS
Pressure: compound ranges
bar .................................................................-0.96 to 1 or 2
bar .........................................................-0.82 to 7, 20 or 35
psi ................................................................. -14 to 15 or 30
psi .....................................................-12 to 100, 300 or 500
Pressure: gauge ranges
bar .........................................................70, 200, 350 or 700
psi ..........................................1,000, 3,000, 5,000 or 10,000
Pressure: absolute ranges
bar ............................................................. 0.025 to 1.1 or 2
bar ................................................................ 0.07 to 7 or 20
Input / output (18 to 28°C/65 to 82°F)
mA range ............................................................ 0 to 24 mA
mA accuracy .....................................±0.015% RDG + 2 µA
RTD range (ohms) ............................................. 84 to 140
RTD accuracy ................................ ±0.015% RDG + 0.02
RTD range RTC accuracy @ 0ºC/32ºF HART
(temperature) ................. -40 to 155ºC/-40 to 311ºF
®
resistor ........................................................... 250 Ω
(temperature) ........±0.10ºC/0.18ºF
Peak hold capture ........................................50 milliseconds
Switch test input ..................................................5V (<1mA)
Temperature effect outside 18 to 28°C/65 to 82°F ±0.001% F.S./°C.
Media compatibility
Nickel plated brass and 316 stainless steel
psi ............................................................... 0.35 to 16 or 30
psi ................................................................ 1 to 100 or 300
Pressure: differential ranges (HPC550Ex only)
mbar ......................................................... ±25, ±70 or ±350
psi ................................................................ ±0.35, ±1 or ±5
Engineering units (built-in)
User selectable ........................................................ 15 units
(bar, mbar, MPa, kPa, inHg@0°C, mmHg@0°C, kg/cm2, mmH2O@4˚C,
O@20˚C, psi, inH2O@4˚C, inH2O@20˚C, inH2O@60˚F, cmH2O@4˚C,
mmH
2
O@20˚C)
cmH
2
Pressure accuracy ambient temp. (18 to 28°C/65 to 82°F)
±25 mbar / 0.35 psi .......................................... ±0.10% F.S.
±70, 350 mbar / 1, 5 psi...................................±0.05% F.S.
All other pressure ranges ....... ±0.025% RDG + 0.01% F.S.
Vacuum ..........................................................±0.025% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference standard uncertainty, 1 Year typical long-term stability, operated inside the rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure­ments or enter the reference pressure for absolute measurements.
Pressure accuracy ambient temp. (0 to 45°C/32 to 113°F)
±25 mbar / 0.35 psi .......................................... ±0.15% F.S.
±70, 350 mbar / 1, 5 psi...................................±0.10% F.S.
All other pressure ranges ......... ±0.04% RDG + 0.01% F.S.
Vacuum ............................................................±0.05% F.S.
F.S. (full scale) is the numerical value of the positive pressure range. Temperature effect -10 to 0°C / 14 to 32°F ±0.005% F.S./°C.
Accuracy includes hysteresis, nonlinearity, repeatability and reference standard uncertainty, 1 Year typical long-term stability, operated inside the rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure­ments or enter the reference pressure for absolute measurements.
Environmental
Operating temperature .................. -10 to 45°C/14 to 122°F
Storage temperature ......................-20 to 60°C/-4 to 140°F
Ingress protection rating ...............................................IP54
Pressure connection
All calibrators ............................................ 1/8” BSP female
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
Pressure overload
Overload alarm ......... “OL” in display at approx. +20% F.S.
Power supply
Battery ................................................ 4 x 1.5 VDC Alkaline
Battery type ....................................AA, LR6, MN1500, AM3
Battery lifetime ...................... Typically more than 35 hours
Low battery indicator ..................................................... Yes
Instrument dimensions (LxWxH)
Calibrator ........................... 201x99x50 mm / 8.3x3.9x2.0 in
HPC550 weight (incl. battery) ......................635 g / 22.4 oz
HPC552 weight (incl. battery) ......................665 g / 23.5 oz
Calibrator, shipping .......... 243x180x80 mm/ 9.6x7.1x3.1 in
Calibrator weight, shipping .........................1.1 kg / 39.5 oz
Miscellaneous
Compliance: EN 60079-0 : 2009, EN 600079-11 : 2007 & CISPR 11, Edition 5.0 - 2009 Class “B”
Display
LCD ..................................................... Graphical (with light)
Display resolution ..................................................... 5 digits
Display update ...................................... 3 times per second
Ex Certifications
ATEX ..................... II 2 Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.........................................................KEMA 10 ATEX 1068 X
IECEx .......................... Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.............................................................. IECEx CSA 10.0013
www.jofra.com 3HPC550Ex/552Ex • Handheld Pressure Calibrator