Ametek HPC550Ex, HPC 552Ex Data sheet

p r e s s u r e
» Ex Safety Certifications
ATEX: II 2 G Ex ia IIB T3 Gb (Ta=-10°C to + 45°C) KEMA 10 ATEX 1068 X IECEx: Ex ia IIB T3 Gb (Ta=-10°C to +45°C) IECEx CSA 10.0013
» Wide pressure range
25 mbar to 700 bar FS (0.35 to 10,000 psi)
» High accuracy
±0.025% of reading +0.01% F.S.
» True field calibrator
Fully temperature compensated
Handheld Pressure Calibrator
HPC550Ex Family
Intrinsically
safe
» Single or dual sensor versions
Chose between HPC550Ex single senror calibrator, or HPC552Ex dual sensor cali­brator. A HPC552Ex might be an alternative to two separate calibrators, saving invest-
ment and cost of ownership
» Full set of intelligent features
Wide selection of useful functions and fea­tures. Damping, leak test, % error calcula­tion, min/max, switch test, etc.
» Thermometer
High accuracy thermometer, Pt100 sensor.
» Intrinsically Safety - Apparatus
- IECEx and EU Ex standards
JOFRA HPC550/552Ex are intended for use in explosively hazardous areas and designed to prevent ignition by electrical,
sparking or heating effects.
ISO 9001 Manufacturer
Specification Sheet SS-HPC550Ex
JOFRA HPC550/552Ex calibrators feature deadweight tester accuracy in a modern digital package.
The HPC550/552Ex can be used in a very broad range of applications from simple tool type jobs to complex calibration jobs in custody transfer systems. Including potential hazardous areas in Oil, Gas and Chemical industries.
The HPC550/552Ex series has been designed to meet high accuracy pressure calibration applications and faciliate your tasks. HPC550/552Ex offers features such as user configurable information display, 15 different pressure units, transmitter supply, mA input, % error calculation, volt­age measurement, serial communication, and external pressure module capability. The accuracy of the HPC550/552Ex calibrators is specified in % of reading to ensure an even better accuracy and wider applicable pressure range. The HPC is temperature compensated from 0 to 45ºC/32 to 113ºF for on-site operation. It is a truly superior pressure calibrator for laboratory and field use, bringing laboratory accuracy into the field.
The pressure calibrator of choice in potential explosive atmospheres. The intrinsically safe HPC550/552Ex calibrators complies with ATEX / IECEx certifications and are an extension of JOFRA´s well known pressure cali­brator range.
HPC550/552Ex meet the needs of technicians who install, maintain, calibrate and troubleshoot equipment in petro-chemical plants, on oil platforms, in refineries, governmental bodies, commercial organizations and any location subject to the risk of potential explosion hazardous atmospheres.
Clear graphical display
Large backlit graphical display shows current status and mode, 1, 2 or 3 measurement windows, to suit your applications and demands.
Full set of features
Perform semi-automatic pressure switch tests, leak test, % error cal­culation, switch in HART resistor or other calibration tasks through the outstanding functions and features of the HPC550Ex.
Intuitive menu system
Combination of “soft keys” and cursor keypad ensures easy opera­tion.
Temperature measurement
High accuracy temperature measurement port by use of he optional Pt100 sensor. A superb instrument for easy and convenient tempera­ture measurement.
Electrical connections
HPC calibrators are well equipped and include inputs for mA, switches and temperature measurements.
Units
15 different engineering units on pressure measurements.
Zero
To keep high accuracy, a dedicated zero button is available to pro­vide convenient zero before test.
ON / OFF
Auto shut-off to expand battery life time (user programmable).
Pressure connections
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
What is an Ex area?
Ex areas can be known by different names such as “Hazardous Locations”, “Hazardous Areas” “Explosive Atmospheres”, and the like and relate to areas where flammable liquids, vapours, gases or combustible dusts are likely to occur in quantities sufficient to cause a fire or explosion.
The modern day automation of industry has meant an increased need to use equipment in Ex areas. Such equip­ment is termed “Ex equipment”.
What is ATEX?
The ATEX directive consists of two EU directives describ­ing which equipment and work environment is allowed in an environment with an explosive atmosphere.
ATEX derives its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.
Where does ATEX apply? All the 24 member coun­tries of the European Union, plus Norway, Iceland and Liechtenstein, are subject to the directives.
Where do you commonly use Ex equipment?
•Automotiverefuelingstationsorpetrolstations
•Oilrefineries,rigsandprocessingplants
•Chemicalprocessingplants
•Printingindustries,paperandtextiles
•Hospitaloperatingtheatres
•Aircraftrefuelingandhangars
•Surfacecoatingindustries
•Seweragetreatmentplants
•Gaspipelinesanddistributioncenters
•Woodworkingareas
•Sugarrefineries
What is IECEx?
The objective of the IECEx System is to facilitate interna­tional trade in equipment and services for use in explo­sive atmospheres, while maintaining the required level of safety, to offer:
• Internationalconfidenceintheproductassessmentpro-
• HPCExfamilyiscertifiedbyCSA,statingIECExbeing
• MaintainingInternationalConfidenceinequipmentand
cess
the certification of the future for America
services covered by IECEx Certification
2 www.jofra.com Handheld Pressure Calibrator HPC550Ex/552Ex
FUNCTIONAL SPECIFICATIONS
Pressure: compound ranges
bar .................................................................-0.96 to 1 or 2
bar .........................................................-0.82 to 7, 20 or 35
psi ................................................................. -14 to 15 or 30
psi .....................................................-12 to 100, 300 or 500
Pressure: gauge ranges
bar .........................................................70, 200, 350 or 700
psi ..........................................1,000, 3,000, 5,000 or 10,000
Pressure: absolute ranges
bar ............................................................. 0.025 to 1.1 or 2
bar ................................................................ 0.07 to 7 or 20
Input / output (18 to 28°C/65 to 82°F)
mA range ............................................................ 0 to 24 mA
mA accuracy .....................................±0.015% RDG + 2 µA
RTD range (ohms) ............................................. 84 to 140
RTD accuracy ................................ ±0.015% RDG + 0.02
RTD range RTC accuracy @ 0ºC/32ºF HART
(temperature) ................. -40 to 155ºC/-40 to 311ºF
®
resistor ........................................................... 250 Ω
(temperature) ........±0.10ºC/0.18ºF
Peak hold capture ........................................50 milliseconds
Switch test input ..................................................5V (<1mA)
Temperature effect outside 18 to 28°C/65 to 82°F ±0.001% F.S./°C.
Media compatibility
Nickel plated brass and 316 stainless steel
psi ............................................................... 0.35 to 16 or 30
psi ................................................................ 1 to 100 or 300
Pressure: differential ranges (HPC550Ex only)
mbar ......................................................... ±25, ±70 or ±350
psi ................................................................ ±0.35, ±1 or ±5
Engineering units (built-in)
User selectable ........................................................ 15 units
(bar, mbar, MPa, kPa, inHg@0°C, mmHg@0°C, kg/cm2, mmH2O@4˚C,
O@20˚C, psi, inH2O@4˚C, inH2O@20˚C, inH2O@60˚F, cmH2O@4˚C,
mmH
2
O@20˚C)
cmH
2
Pressure accuracy ambient temp. (18 to 28°C/65 to 82°F)
±25 mbar / 0.35 psi .......................................... ±0.10% F.S.
±70, 350 mbar / 1, 5 psi...................................±0.05% F.S.
All other pressure ranges ....... ±0.025% RDG + 0.01% F.S.
Vacuum ..........................................................±0.025% F.S.
F.S. (full scale) is the numerical value of the positive pressure range.
Accuracy includes hysteresis, nonlinearity, repeatability and reference standard uncertainty, 1 Year typical long-term stability, operated inside the rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure­ments or enter the reference pressure for absolute measurements.
Pressure accuracy ambient temp. (0 to 45°C/32 to 113°F)
±25 mbar / 0.35 psi .......................................... ±0.15% F.S.
±70, 350 mbar / 1, 5 psi...................................±0.10% F.S.
All other pressure ranges ......... ±0.04% RDG + 0.01% F.S.
Vacuum ............................................................±0.05% F.S.
F.S. (full scale) is the numerical value of the positive pressure range. Temperature effect -10 to 0°C / 14 to 32°F ±0.005% F.S./°C.
Accuracy includes hysteresis, nonlinearity, repeatability and reference standard uncertainty, 1 Year typical long-term stability, operated inside the rated temperature span and pressure range.
For optimal performance “zero” the unit for gauge/differential measure­ments or enter the reference pressure for absolute measurements.
Environmental
Operating temperature .................. -10 to 45°C/14 to 122°F
Storage temperature ......................-20 to 60°C/-4 to 140°F
Ingress protection rating ...............................................IP54
Pressure connection
All calibrators ............................................ 1/8” BSP female
Adapters to 1/4” NPT male and 1/4” BSP female are included as standard.
Pressure overload
Overload alarm ......... “OL” in display at approx. +20% F.S.
Power supply
Battery ................................................ 4 x 1.5 VDC Alkaline
Battery type ....................................AA, LR6, MN1500, AM3
Battery lifetime ...................... Typically more than 35 hours
Low battery indicator ..................................................... Yes
Instrument dimensions (LxWxH)
Calibrator ........................... 201x99x50 mm / 8.3x3.9x2.0 in
HPC550 weight (incl. battery) ......................635 g / 22.4 oz
HPC552 weight (incl. battery) ......................665 g / 23.5 oz
Calibrator, shipping .......... 243x180x80 mm/ 9.6x7.1x3.1 in
Calibrator weight, shipping .........................1.1 kg / 39.5 oz
Miscellaneous
Compliance: EN 60079-0 : 2009, EN 600079-11 : 2007 & CISPR 11, Edition 5.0 - 2009 Class “B”
Display
LCD ..................................................... Graphical (with light)
Display resolution ..................................................... 5 digits
Display update ...................................... 3 times per second
Ex Certifications
ATEX ..................... II 2 Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.........................................................KEMA 10 ATEX 1068 X
IECEx .......................... Ex ia IIB T3 Gb (Ta=-10ºC to +45ºC)
.............................................................. IECEx CSA 10.0013
www.jofra.com 3HPC550Ex/552Ex • Handheld Pressure Calibrator
Function / Feature HPC550 HPC552
Single sensor high accuracy pressure calibrator
Dual sensor high accuracy pressure calibrator
mA measurement
Voltage measurement
24 VDC transmitter supply
High speed pressure switch test
Temperature measurement with external RTD sensor
JOFRA APM pressure module connection
RS232 communication - Service and maintenance only (not to be used in hazardous areas)
On-line calculation of sensor error %
Automatic leak test timer function
High speed min./max. hold
Delta / sum calculation on pressure measurements (HPC552Ex)
Display contrast adjustment
Instrument setup lock
Storage of 5 setups
Setup of automatic off timer
Setup of number of display windows / measurement channels
Setup of temperature sensor RTD type
Select display high or low resolution
Setup of backlight timer
HART resistor on/off
Normal or dampened display update rate
   
 
                           
JOFRA HPC Ex features a custom set up display, 1, 2 or 3 lines / measurement chancels, easy to configure for the indi­vidual task
4 www.jofra.com Handheld Pressure Calibrator HPC550Ex/552Ex
This table shows the resolutions that can be obtained by the HPC calibrators throughout all engineering units.
HPC550Ex/HPC552Ex Ranges and Overpressure Ratings
BAR
Range (bar) 25mbar 70mbar 350mbar 1 1.1 2 7 20 35 70 200 350 700
Burst pressure (bar) 1.4 1.4 7 20 20 20 70 133 133 677 677 677 1000
Proof pressure (bar) 70mbar 200mbar 1 2 2 4 14 40 67 200 400 677 1000
Static pressure (bar) 70mbar 7 7 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
PSI
Range (psi) 0.35 1 5 15 16 30 100 300 500 1000 3000 5000 10000
Burst pressure (psi) 10 10 100 300 300 300 1000 2000 2000 10000 10000 10000 15000
Proof pressure (psi) 1 3 15 30 30 60 200 600 1000 3000 6000 10000 15000
Static pressure (psi) 1 100 100 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
HPC550Ex/HPC552Ex Resolutions
psi 0.4000 1.0000 5.0000 15.000 16.000 30.000 100.00 300.00 500.00 1000.00 3000.00 5000.00 10000.00
bar 0.0689 0.0689 0.3447 1.0342 1.1032 2.0684 6.8947 20.684 34.474 68.947 206.84 344.74 689.47
mbar 27.579 68.948 344.74 1034.2 1103.2 2068.4 6894.8 20684 344.74 689.48 n/a n/a n/a
kPa 2.7579 6.8948 34.474 103.42 110.32 206.84 689.48 2068.4 3447.4 6894.8 2068.4 3447.4 68948
MPa 0.0028 0.0068 0.0344 0.1034 0.1103 0.2068 0.6894 2.0684 3.447 6.8948 20.684 34.474 68.948
2
kg/cm
cmH
O@4°C 28.124 70.309 351.54 1054.6 1124.9 2109.3 7030.9 21093 35154 70309 n/a n/a n/a
2
cmH2O@20°C 28.173 70.434 352.17 1056.5 1126.9 2113.0 7043.4 21130 35217 70434 n/a n/a n/a
mmH2O@4°C 281.24 703.09 3515.4 10546 11249 21093 70309 n/a n/a n/a n/a n/a n/a
mmH
O@20°C 281.73 704.34 3521.7 10565 11269 21130 70434 n/a n/a n/a n/a n/a n/a
2
inH2O@4°C 11.072 27.681 138.40 415.21 442.89 830.42 2768.1 8304.2 13840 27681 83042 n/a n/a
inH
O@20°C 11.092 27.730 138.65 415.95 443.68 831.89 2773.0 8318.9 13865 27730 83189 n/a n/a
2
inH2O@60°F 11.083 27.708 138.54 415.61 443.32 831.23 2770.8 83123 13854 27708 83123 n/a n/a
mmHg@0°C 20.686 51.715 258.58 775.73 827.44 1551.5 5171.5 15515 25858 51715 n/a n/a n/a
inHg@0°C 0.8144 2.0360 10.108 30.540 32.576 61.081 203.6 610.81 1018.0 2036.0 6108.1 10180 20360
0.0281 0.0703 0.3515 1.0546 1.1248 2.1092 7.0307 21.092 35.153 70.307 210.92 351.53 703.07
Proof pressure - maximum allowable pressure without a shift in calibration.
Burst pressure - sensor damaged or destroyed, some risk of personal injury.
Static pressure - differential units only. Maximum allowed common mode pressure between both points.
Compound ranges - the data for the 1 bar range also applies to the -1 to +1 bar compound range, the data for the 2 bar
range also applies to the -1 to +2 bar compound range.
Absolute ranges - the data for the 1.1, 2, 7 and 20 bar ranges also applies to the absolute pressure versions of those
ranges.
STANDARD DELIVERY (HPC Calibrator)
• HPC550Ex or HPC552Ex calibrator
• Traceable calibration certificate (NIST) with pressure
and vacuum performance
• 4 x 1.5 volt batteries
• Test leads: red and black
• User manual
www.jofra.com 5HPC550Ex/552Ex • Handheld Pressure Calibrator
ORDERING INFORMATION
Order number Description
HPC Type
550 Model
Pressure range
25MD ±25 mbar / 0.35 psi differential
70MD ±70 mbar / 1 psi differential
350MD ±350 mbar / 5 psi differential
001A 0.025 to 1.1 bar / 16 psi absolute
001C -0.96 to 1 bar / 15 psi gauge/compound
002A 0.025 to 2 bar / 30 psi absolute
002C -0.96 to 2 bar / 30 psi gauge/compound
007A 0.070 to 7 bar / 100 psi absolute
007C -0.82 to 7 bar / 100 psi gauge/compound
020A 0.070 to 20 bar / 290 psi absolute
020C -0.82 to 20 bar / 290 psi gauge/compound
035C -0.82 to 35 bar / 500 psi gauge/compound
070G 0 to 70 bar / 1,000 psi gauge
200G 0 to 200 bar / 2,900 psi gauge
350G 0 to 350 bar / 5,000 psi gauge
700G 0 to 700 bar / 10,000 psi gauge
Calibration certificate
G NIST traceable calibration certificate
Accessories (Optional)
C Soft case (Not to be used in hazardous areas)
I
T Temperature sensor Pt100
HPC 550 035C G CIT IND HPC550, -0.82 to 35 bar, NIST traceable certificate, soft case, interface kit,
Interface Kit 3.5 mm jack to RS232 - Service & maintenance only (Not to be used in hazardous areas)
Pressure system
IND Calibrator only
Sample order number
temperature sensor, calibrator only
6 www.jofra.com Handheld Pressure Calibrator HPC550Ex/552Ex
ORDERING INFORMATION
Order number Description
HPC Type
552 Model
Port 1 Port 2 Pressure range (Port 1 - lowest pressure, Port 2 - highest pressure)
001A 001A 0.025 to 1.1 bar / 16 psi absolute
001C 001C -0.96 to 1 bar / 15 psi gauge/compound
002A 002A 0.025 to 2 bar /30 psi absolute
002C 002C -0.96 to 2 bar / 30 psi gauge/compound
007A 007A 0.070 to 7 bar / 100 psi absolute
007C 007C -0.82 to 7 bar / 100 psi gauge/compound
020A 020A 0.070 to 20 bar / 290 psi absolute
020C 020C -0.82 to 20 bar / 290 psi gauge/compound
035C 035C -0.82 to 35 bar / 500 psi gauge/compound
070G 070G 0 to 70 bar / 1,000 psi gauge
200G 200G 0 to 200 bar / 2,900 psi gauge
350G 350G 0 to 350 bar / 5,000 psi gauge
700G 700G 0 to 700 bar / 10,000 psi gauge
Calibration certificate
G NIST traceable calibration certificate
Accessories (Optional)
C Soft case (Not to be used in hazardous areas)
I
T Temperature sensor Pt100
HPC 552 035C 350G G CIT IND HPC552, port 1: -0.82 to 35 bar, port 2: 0 to 350 bar, NIST trace-
Interface Kit 3.5 mm jack to RS232 - Service and maintenance only (Not to be used in hazardous areas)
Pressure system
IND Calibrator only
Sample order number
able certificate, soft case, interface kit, temperature sensor, calibra­tor only
www.jofra.com 7HPC550Ex/552Ex • Handheld Pressure Calibrator
ACCESSORIES
Useful soft case - Option C
Not to be used in hazardous areas!
The HPC550Ex can be delivered with a soft case as an option. The handy soft case is designed for protection during transport. The soft case has separate compartments for HPC550Ex (w/Velcro strap), test leads, test hoses, temperature probe, and JOFRA APM pressure module. A shoulder strap ensures convenient transportation when climbing lad­ders, etc. and the handy strap on the back makes it possible to hang the instrument on a valve, ladder etc. The manual and calibration documents fit into a pocket on the front of the soft case.
Interface kit - Option I
Not to be used in hazardous areas!
For Service and maintenance only
Special 3.5 mm jack to Sub D, RS232 interface cable for HPC550 and HPC552. Is used during recalibration / adjustment. No disassembly of the HPC is necessary for recalibration / adjustment.
Temperature sensor - Option T
To utilize the thermometer utility of the HPC500 family, a ruggedized handheld temperature sensor is available. The sensor comes as a ready­to-use probe with handle and coiled cable with LEMO connector for HPC550Ex and HPC552Ex. The sensor is built with a high accuracy Pt100 element, accuracy ±0.05ºC / ±0.27ºF. Sensor dimensions, without handle and cable, ø 4x200 mm/stainless steel.
AMETEK Calibration Instruments
is one of the world’s leading manufacturers and developers of calibration instruments for temperature, pressure and process signals as well as for temperature sensors both from a commercial and a technological point of view.
JOFRA Temperature Instruments
Portable precision thermometers. Dry-block and liquid bath calibrators: 5 series, with more than 25 models and temperature ranges from -90° to 1205°C / -130° to 2200°F. All featuring speed, portability, accuracy and advanced documenting functions with JOFRACAL calibration software.
JOFRA Pressure Instruments
Convenient electronic systems ranging from -25 mbar to 1000 bar (0.4 to 15,000 psi) - multiple choices of pressure ranges, pumps and accuracies, fully temperature-compensated for problem-free and accurate field use.
JOFRA Signal Instruments
Process signal measurement and simulation for easy control loop calibration and measurement tasks - from handheld field instruments to laboratory reference level bench top instruments.
JOFRA / JF Marine Instruments
A complete range of calibration equipment for temperature, pressure and signal, approved for marine use.
FP Temperature Sensors
A complete range of temperature sensors for industrial and marine use.
M&G Pressure Testers
Pneumatic floating -ball or hydraulic piston dead weight testers with accuracies to 0.015% of reading.
M&G Pumps
Pressure generators from small pneumatic “bicycle” style pumps to hydraulic pumps generating up to 1,000 bar (15,000 psi).
AMETEK Denmark A/S Gydevang 32-34 | 3450 Allerød | Denmark T: +45 4816 8000 | ametek@ametek.dk
Sales & Service: Europe, Asia, Africa, Middle East and South America
Information in this document is subject to change without notice. ©2011, by AMETEK, Inc., www.ametek.com. All rights reserved.
8 www.jofra.com
.. .becaus e c alibrat ion is a ma tte r of co nfi dence
AMETEK Mansfield & Green (North America)
T: +1 800 527 9999 | cal.info@ametek.com
AMETEK Singapore Pte. Ltd. (Singapore) T: +65 6 484 2388 | aspl@ametek.com.sg
AMETEK Inc. Beijing Rep. Office (China)
T: +86 10 8526 2111 | jofra@ametek.com.cn
AMETEK GmbH (Germany) T: +49 2159 9136 510 | info.mct-de@ametek.de
AMETEK Calibration Instruments (UK) T: +44 (0) 1243 833 302 | jofra@ametek.co.uk
www.jofra.com
Pub code SS-HPC550Ex Issue 1102
Loading...