American Standard T6179, T6180, T6181 User Manual

Installation
Instructions
THE
“”
COLLECTION
by
BATH/SHOWER
TRIM KITS
T6179 T6180 T6181
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
M968411A
ROUGHING-IN DIMENSIONS Installation for Bath/Shower, Shower only, or Valve only Trim.
Dimensions are for reference.
FINISHED WALL
5-1/8" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
TOP OF TUB RIM
7-1/2" REF.
1" MIN.
5-5/8" REF.
BOTTOM OF TUB
3/4" TO 2-3/8"
1/2" NPT
1/2" NPT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
7-1/8"
4"
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
1
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
Mount ESCUTCHEON (3) to valve body with SCREWS (4).
Push DIAL PLATE (9) over CAP (1) and into the three alignment holes in ESCUTCHEON (3)
Remove PIPE CAP (5) and PIPE PLUG (9) from shower pipe and tub filler pipe.
Install SHOWER ARM (6), SHOWER HEAD (7) and TUB FILLER SPOUT (8) by threading onto pipe nipples using teflon tape or pipe sealant.
Align HANDLE (10) and push onto VALVE STEM (11).
Insert HANDLE SCREW (13) and tighten securley.
Push INDEX BUTTON (12) into end of Handle (10).
6
7
9
A
Required Tools
Flat Blade Screwdriver
Phillips Screwdriver
Adjustable Wrench
Plumbers' Putty or Caulking
Channel Locks
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE
12
13
2
(3) ALIGNMENT
HOLES FOR DIAL PLATE
1
3
9
11
4
10
8
5
TO GAIN ACCESS TO VALVE FOR SERVICING
2
Remove HANDLE and TRIM. See step one and reverse assembly procedure.
HANDLE
and TRIM
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit. Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7) for debris. Clean inside sealing surfaces of VALVE BODY (8). Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see above for installing TRIM and HANDLE. If it still leaks, replace pressure balancing unit (M952100-0070A).
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly. Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective. Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down. Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE (1).
3
4
9
2
1
LARGE OUTLET
ROTATE 180
˚
5
6
8
7
ADJUST HOT LIMIT STOP
3
5
INLETS
BACK TO BACK INSTALLATION
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
3
9
7
1
5
1
3
3
1
0
1
5
1
5
1
4
3
2
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
5
1
3
1
1
9
7
5
3
1
1
4
(Larger Numbers)
0 1 3 5 7 9 11 13 15
9
7
5
3
1
COLDER
1
5
1
3
1
1
TEST INSTALLED FITTING
4
Turn VALVE (1) "off".
With HANDLE (2) in "off" position, turn on water supplies and check all connections for leaks.
Operate HANDLE (2) and flush water lines thoroughly. Pull DIVERTER (3) up and check SHOWER (4) for proper operation.
Check SPOUT (5) and SHOWER (4) connections for leaks.
4
5
M968411A
1
2
3
Loading...
+ 1 hidden pages