American Standard T555.502, T555.501, T555.500 User Manual 2

Installation
TOWNSQUARE
Instructions
BATH/SHOWER TRIM KIT
PRESSURE BALANCING BATH AND SHOWER TRIM KIT
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Required Tools
Phillips Screwdriver
Flat Blade Screwdriver
Adjustable Wrench
T555.500 T555.501 T555.502
Channel Locks
Certified to comply with ANSI A112.18.1
M968235 Rev. 1.5
Plumbers' Putty or Caulking
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to
wall, note roughing-in dimensions.
2" REF.
74" FOR HEAD CLEARANCE
18"
OPTIONAL
FINISHED WALL
1
8" REF.
7-1/4" REF.
1-3/4" REF.
1/2" I.P.S.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65'' AND 78''
7-5/8"
4"
BOTTOM OF
TUB
TOP OF
TUB RIM
1/2" COPPER
INSTALL TRIM
1
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
Mount ESCUTCHEON (3) to valve body with SCREWS (4).
Remove PIPE CAPS (5) from shower pipe and tub filler pipe.
Install SHOWER ARM (6), SHOWER HEAD (7) by threading onto pipe nipples using teflon tape or pipe sealant.
Install SLIP-ON TUB SPOUT (8). Tighten with
HEX WRENCH supplied.
7
INSTALL HANDLE
2
Install HANDLE BUSHING (1) onto CAP (2).
Find correct position of HANDLE (3) and push HANDLE (3) onto VALVE STEM (4).
Install HANDLE SCREW (5) and push in INDEX CAP (6).
Check proper operation of HANDLE.
Turn water supply on and test installed fitting. Operate valve and diverter spout.
6
5
2
1
3
5
4
8
ADJUST HOT LIMIT STOP
3
By restricting HANDLE rotation and limiting the
amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, you need to adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position
(coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
HEX WRENCH
A
1-3/4" REF.
1
5
6
2
4
3
3
7
9
5
1
3
1
1
3
0
1
5
1
5
1
3
4
2
1
5
1
3
1
1
9
7
5
3
1
2
4
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
5
1
3
1
1
9
7
5
3
1
1
M968235 Rev. 1.5