To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
RECOMMENDED TOOLS
Instructions
T480.508
T480.507
Certified to comply with ANSI A112.18.1
U.S. Patent No. D403,750
M 9 6 8 6 9 8
Phillips Screwdriver
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS
FOR REFERENCE ONLY
4" REF.
74" FOR HEAD
CLEARANCE
Plumbers' Putty or Caulking
FINISHED WALL
7" REF.
Adjustable Wrench
Teflon Tape
1-5/8" TO 3-1/4"
1/2" NPT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78''
5-1/8" REF.
TOP OF TUB RIM
BOTTOM OF TUB
7-5/8" REF.
4" REF.
1/2" COPPER

INSTALL TRIM
1
Remove PLASTER GUARD (1).
Push CAP (2) on valve, place ESCUTCHEON (3) and attach with SCREWS (4).
Install HANDLE (5) by pushing it onto CARTRIDGE STEM (6) and tightening SET SCREW
(7) from below.
Install SHOWER ARM (8) with FLANGE (9). Install SHOWER HEAD (10). See Step 2.
9
8
1
Check proper operation of HANDLE (5) and DIVERTER SPOUT (11).
INSTALL SHOWER HEAD ASSEMBLY
2
REMOVE SHOWER HEAD FROM HOUSING
Hold SHOWERHEAD (1) with one hand and HOUSING (2)
with the other as illustrated.
Rotate SHOWERHEAD (1) clockwise while holding HOUSING (2)
stationary. NOTE: The thread connection is a left hand
thread. Keep turning SHOWERHEAD (1) until it can be
removed from the HOUSING (2).
3
10
5
2
7
4
11
2
1
6
2a
2c
INSTALL HOUSING
Slide HOUSING (2) onto
SHOWER ARM (3).
3
2
INSTALL HOUSING TO SHOWER HEAD
Install HOUSING (2) onto SHOWER HEAD (1). Thread
HOUSING (2) counter-clockwise to install onto SHOWER
HEAD (1). Hand tighten only.
2b
INSTALL SHOWER HEAD
Rap SHOWER ARM (3) threads with Teflon tape.
Tighten SHOWERHEAD (1)
with an adjustable wrench.
Do not over tighten.
TEFLON TAPE
1
1
3
2
M 9 6 8 6 9 8 M 9 6 8 6 9 8 M 9 6 8 6 9 8

ADJUST HOT LIMIT STOP
3
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to
adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
"A"
ADJUSTMENT WHEN WATER IS TOO HOT
TEMPERATURE SETTING NUMBERS
"B"
ADJUSTMENT WHEN WATER IS TOO COLD
PRY RED RING FORWARD AND ROTATE CLOCKWISE
0
1
2
3
4
5
6
"A"
PRY RED RING FORWARD AND ROTATE
COUNTER-CLOCKWISE ONE CLICK
"B"
1
"RED RING"- HOT LIMIT SAFETY STOP
SERVICE
4
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
2
4
3
5
1
CARE:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.