Installation
Instructions
TENDENCE
BATH/SHOWER TRIM KIT
with EverClean™ Finish
Congratulations on purchasing your American Standard faucet with
EverClean finish found only on American Standard faucets.
EverClean Finish
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall,
note roughing-in dimensions.
T086.502
T086.501
T086.500
Certified to comply with ANSI A112.18.1
U.S. Patent No. D403,750
M968388 Rev. 1.1
7"
74" FOR HEAD CLEARANCE
1-5/8"" TO 3-1/4"
FINISHED WALL
1-1/2" REF.
1-1/2" MIN.
1/2" REF.
1/2" NPT
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
7-5/8"
48"
(OPTIONAL)
4"
5" REF.
BOTTOM OF TUB
1/2" NPT
TOP OF TUB RIM
INSTALL TRIM
1
Remove PLASTER GUARD (1).
Push CAP (2) on valve, place ESCUTCHEON HOLDER
(3) and attach with LONG SCREWS (4).
Place ESCUTCHEON (5) and attach with SHORT
SCREWS (6).
Choose one of the DECORATIVE RINGS (7)
and push it onto CAP (2).
Push HANDLE (11) onto cartridge stem
and tighten SET SCREW (12) from below.
NOTE: Lift handle to access SET
SCREW (12)
Install SHOWER ARM (8), SHOWER HEAD (9)
and DIVERTER SPOUT (10).
Check proper operation of HANDLE (11)
and DIVERTER SPOUT (10).
8
9
1
3
4
5
6
6
7
11
12
2
ADJUST HOT LIMIT STOP
TEMPERATURE SETTING NUMBERS
"B"
ADJUSTMENT WHEN WATER IS TOO COLD
PRY RED RING FORWARD AND ROTATE CLOCKWISE
"B"
ADJUSTMENT WHEN WATER IS TOO HOT
"A"
0
1
2
3
4
5
6
"RED RING"- HOT LIMIT SAFETY STOP
PRY RED RING FORWARD AND ROTATE
2
10
"A"
COUNTER-CLOCKWISE ONE CLICK
1
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to
adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
EverClean™ Finish Care Instructions
3
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with
clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
M968388 Rev. 1.1