American Standard T064.60X User Manual

Page 1
Installation
SERIN
T064.60X
BATH/SHOWER TRIM KIT WITH DIVERTER
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended Tools
Flat Blade Screwdriver
Pipe Wrench
Phillips Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note roughing-in dimensions.
Plumbers' Putty or Caulking
1-5/8" TO 3-1/4"
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
Adjustable Wrench
Certified to comply with ANSI A112.18.1
M968836 Rev.1.4
Channel Locks
5-5/8" REF.
74" FOR
HEAD CLEARANCE
OPTIONAL
TOP OF
TUB RIM
FINISHED WALL
8-1/8" REF.
7-1/4" D.
18"
BOTTOM OF
TUB
2-3/8"
6-3/4"
4"
1/2" NPT
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
80'' AND 86'
SHW
TUB
1/2" NPT
1/2" REF.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
"SEE ILLUSTRATION"
5-5/8"
INLETS
1/2" NPT
OUTLETS 1/2" NPT
1-3/4"
5-5/8"
THREADED INLETS (STOPS)
Page 2
INSTALL DIVERTER
1
When finished tiling the wall, remove PLASTER GUARD (1). Remove two screws that secure the DIVERTER LID (2) and remove Lid. Inspect the inside surface of diverter port. Diverter port must be free of any dirt. Clean if necessary.
Install DIVERTER (3) with SCREWS (4) removed with DIVERTER LID (2).
Operate DIVERTER (3). DIVERTER (3) should slide in and out smoothly.
1
INSTALL VALVE TRIM
2
DIVERTER
PORT
2
3
4
Figure 1. Push CAP (1) over VALVE CARTRIDGE (2) until seated against stop. Push CAP (3) over DIVERTER (4) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (5) onto CAP (1) and attach to valve body with SCREWS (6). Mount ESCUTCHEON SUPPORT (7) to ESCUTCHEON HOLDER (5) with SCREWS (8).
Figure 3. Install ESCUTCHEON (9) onto CAP (1) and push flush against finished wall. Escutcheon (9) will snap fit onto ESCUTCHEON SUPPORT (7).
5
7
1
Figure 1.
4
3
2
1
Figure 2.
9
1
6
8
Figure 3.
7
M968836 Rev.1.4
Page 3
ADJUST HOT LIMIT STOP
3
INSTALL HANDLE, DIVERTER KNOB, TUB
4
SPOUT AND SHOWER
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
3
7
9
5
1
3
1
1
3
0
1
5
1
5
1
4
4
2
TO GAIN ACCESS TO VALVE FOR SERVICING
5
(Larger Numbers)
0 1 3 5 7 9 11 13 15
COLDER
3
2
1
5
1
3
1
1
9
7
5
3
1
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
1
5
1
3
1
1
9
7
5
3
1
Unthread LEVER HANDLE, loosen SET SCREW and pull HANDLE off valve stem. To remove Escutcheon assembly reverse steps in Step 3.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit. Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8). Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see above for installing TRIM and HANDLE.
Thread DIVERTER KNOB (1) onto diverter stem. Hold ADAPTER (2) onto VALVE STEM (3) and install ADAPTER SCREW (4) through ADAPTER (2) into VALVE STEM (3).Tighten ADAPTER SCREW (4) to secure ADAPTER (2) to VALVE STEM (3).
Install HANDLE BASE (5) onto ADAPTER (2). Insert SET SCREW (6) into HANDLE BASE (5). Align HANDLE BASE (4) and tighten with HEX WRENCH (7) supplied.
Remove pipe cap and plug from shower and tub rough piping. Install SPOUT ESCUTCHEON (9) onto TUB SPOUT (10). Apply sealant or Teflon tape to threads of tub filler nipple. Thread TUB SPOUT (10) onto tub nipple. Install SHOWER ESCUTCHEON (11) onto SHOWER ARM (12). Apply sealant or Teflon tape to threads on both ends of SHOWER ARM (12) and thread longer leg of SHOWER ARM (12) into shower elbow. Thread SHOWER HEAD (13) onto SHOWER ARM (12).
5
CAUTION: Protect finish on SHOWER HEAD and ARM when installing.
1
11
SHR. ELBOW
PIPE
12
PLUG
13
1
5
4
3
6
2
TUB NIPPLE
7
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly. Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective.
9
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting.
10
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down. Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE (1).
4
LARGE OUTLET
ROTATE 180˚
1
5
6
8
7
5
3
9
2
INLETS
BACK TO BACK INSTALLATION
M968836 Rev.1.4
PIPE CAP
Page 4
M962818-YYY0A
DEEP ROUGH KIT
(NOT SHOWN)
SERIN
BATH/SHOWER TRIM KIT
WITH DIVERTER
MODEL NUMBER
T064.60X
M962641-0070A
ESCUTCHEON HOLDER
A912632-0070A
O-RING
A953929-0070A
DIVERTER KIT
M907053-YYY0A
CAP
M962493-YYY0A
SHOWER ARM & FLANGE
M953540-YYY0A
SHOWER HEAD
M907103-YYY0A
DIVERTER COVER
A950842-YYY0A
ESCUTCHEON WITH DIVERTER
M909917-YYY0A
DIVERTER KNOB
A918477-0070A
HANDLE SCREW
Replace the "YYY" with appropriate finish code
CHROME SATIN NICKEL
For toll-free information and answers to your questions, call:
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc. © AS America, Inc. 2008
Weekdays 8:00 a.m. to 7:00 p.m. EST
002 295
HOT LINE FOR HELP
1 (800) 442-1902
IN MEXICO 01-800-839-12-00
M918039-0070A
HANDLE ADAPTER
M962495-YYY0A
TUB SPOUT ESCUTCHEON
M962426-YYY0A
HANDLE KIT
M962209-YYY0A
SPOUT KIT
922388-YYY0A
STREAM STRAIGHTENER
M968836 Rev.1.4