Installation
Instructions
SERIN
™
T064.60X
BATH/SHOWER TRIM KIT WITH DIVERTER
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
To ensure that your installation proceeds smoothly-please read these
instructions carefully before you begin.
Recommended Tools
Flat Blade Screwdriver
Pipe Wrench
Phillips Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note
roughing-in dimensions.
Plumbers' Putty or Caulking
1-5/8" TO 3-1/4"
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH
CLEAR WATER. DRY WITH A SOFT COTTON
FLANNEL CLOTH.
Adjustable Wrench
Certified to comply with ANSI A112.18.1
M968836 Rev.1.4
Channel Locks
5-5/8" REF.
74" FOR
HEAD CLEARANCE
OPTIONAL
TOP OF
TUB RIM
FINISHED WALL
8-1/8" REF.
7-1/4" D.
18"
BOTTOM OF
TUB
2-3/8"
6-3/4"
4"
1/2" NPT
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
80'' AND 86'
SHW
TUB
1/2" NPT
1/2" REF.
DO NOT: DO NOT CLEAN THE PRODUCT WITH
SOAPS, ACID, POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH A COARSE
SURFACE.
"SEE ILLUSTRATION"
5-5/8"
INLETS
1/2" NPT
OUTLETS 1/2" NPT
1-3/4"
5-5/8"
THREADED INLETS (STOPS)

INSTALL DIVERTER
1
When finished tiling the wall, remove PLASTER GUARD (1).
Remove two screws that secure the DIVERTER LID (2) and
remove Lid. Inspect the inside surface of diverter port.
Diverter port must be free of any dirt. Clean if necessary.
Install DIVERTER (3) with SCREWS (4) removed with
DIVERTER LID (2).
Operate DIVERTER (3). DIVERTER (3) should slide in
and out smoothly.
1
INSTALL VALVE TRIM
2
DIVERTER
PORT
2
3
4
Figure 1. Push CAP (1) over VALVE CARTRIDGE (2) until
seated against stop. Push CAP (3) over DIVERTER (4) until
seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (5) onto CAP (1)
and attach to valve body with SCREWS (6). Mount
ESCUTCHEON SUPPORT (7) to ESCUTCHEON HOLDER (5)
with SCREWS (8).
Figure 3. Install ESCUTCHEON (9) onto CAP (1) and push
flush against finished wall. Escutcheon (9) will snap fit onto
ESCUTCHEON SUPPORT (7).
5
7
1
Figure 1.
4
3
2
1
Figure 2.
9
1
6
8
Figure 3.
7
M968836 Rev.1.4

ADJUST HOT LIMIT STOP
3
INSTALL HANDLE, DIVERTER KNOB, TUB
4
SPOUT AND SHOWER
By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a flat
blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4)
and NUMBERS (5) on HOT LIMIT STOP (1) for
indication.
3
7
9
5
1
3
1
1
3
0
1
5
1
5
1
4
4
2
TO GAIN ACCESS TO VALVE FOR SERVICING
5
(Larger Numbers)
0 1 3 5 7 9 11 13 15
COLDER
3
2
1
5
1
3
1
1
9
7
5
3
1
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
1
5
1
3
1
1
9
7
5
3
1
Unthread LEVER HANDLE, loosen SET SCREW and pull
HANDLE off valve stem.
To remove Escutcheon assembly reverse steps in Step 3.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2).
Remove three SCREWS (3) from FIXATION RING (4) and pull
out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of
PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside
sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1).
Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE.
Thread DIVERTER KNOB (1) onto diverter stem.
Hold ADAPTER (2) onto VALVE STEM (3) and install
ADAPTER SCREW (4) through ADAPTER (2) into
VALVE STEM (3).Tighten ADAPTER SCREW (4) to
secure ADAPTER (2) to VALVE STEM (3).
Install HANDLE BASE (5) onto ADAPTER (2). Insert
SET SCREW (6) into HANDLE BASE (5). Align
HANDLE BASE (4) and tighten with HEX WRENCH
(7) supplied.
Remove pipe cap and plug from shower and tub
rough piping.
Install SPOUT ESCUTCHEON (9) onto TUB SPOUT (10).
Apply sealant or Teflon tape to threads of tub filler
nipple. Thread TUB SPOUT (10) onto tub nipple.
Install SHOWER ESCUTCHEON (11) onto SHOWER
ARM (12). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (12) and thread longer
leg of SHOWER ARM (12) into shower elbow.
Thread SHOWER HEAD (13) onto SHOWER ARM (12).
5
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
1
11
SHR.
ELBOW
PIPE
12
PLUG
13
1
5
4
3
6
2
TUB
NIPPLE
7
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7)
and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of
piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.
9
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5).
Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
10
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up
and the large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting.
Top flange should butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
4
LARGE OUTLET
ROTATE 180˚
1
5
6
8
7
5
3
9
2
INLETS
BACK TO BACK INSTALLATION
M968836 Rev.1.4
PIPE
CAP

M962818-YYY0A
DEEP ROUGH KIT
(NOT SHOWN)
SERIN
™
BATH/SHOWER TRIM KIT
WITH DIVERTER
MODEL NUMBER
T064.60X
M962641-0070A
ESCUTCHEON HOLDER
A912632-0070A
O-RING
A953929-0070A
DIVERTER KIT
M907053-YYY0A
CAP
M962493-YYY0A
SHOWER ARM & FLANGE
M953540-YYY0A
SHOWER HEAD
M907103-YYY0A
DIVERTER COVER
A950842-YYY0A
ESCUTCHEON
WITH DIVERTER
M909917-YYY0A
DIVERTER KNOB
A918477-0070A
HANDLE SCREW
Replace the "YYY" with
appropriate finish code
CHROME
SATIN NICKEL
For toll-free information and answers to your questions, call:
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
Weekdays 8:00 a.m. to 7:00 p.m. EST
002
295
HOT LINE FOR HELP
1 (800) 442-1902
IN MEXICO 01-800-839-12-00
M918039-0070A
HANDLE ADAPTER
M962495-YYY0A
TUB SPOUT ESCUTCHEON
M962426-YYY0A
HANDLE KIT
M962209-YYY0A
SPOUT KIT
922388-YYY0A
STREAM STRAIGHTENER
M968836 Rev.1.4