American Standard T050.210 User Manual

Installation
Instructions
T050.210
TRIM KIT for CENTRAL THERMOSTAT with VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
6-11/16"
N
E
P
O
/
P
O
T
Certified to comply with ANSI A112.18.1M ASSE 1016
C
L
9-1/8"
Recommended Tools
Flat Blade Screwdriver
CARE INSTRUCTIONS:
To keep your new faucet looking new, please follow these simple care instructions:
DO: Simply rinse the faucet clean with clear water. Dry the faucet with a soft cotton cloth.
DO NOT: Do not use any abrasive cleaners, cloths, or paper towels. Do not use any cleaning agents containing acids, polish abrasives, or harsh cleaners or soaps.
Regular and routine cleaning will reduce the need for heavy cleaning and polishing. If heavy cleaning is required, the following procedures are recommended:
100
1-11/16" to 2-1/2"
Phillips Screwdriver
FINISHED WALL
Remove as much surface dirt and film using clear water and soft cotton cloth (as described above).
Use any of the following to remove tough surface film and build-up: Mild liquid detergents Clear ammonia free liquid glass cleaners Non-acidic, non-abrasive gentle liquid or fully dissolved powder cleansers mixed according to manufacturers directions. Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to thoroughly remove cleaner or polish and blot dry with a soft cotton cloth.
Failure to follow these care instructions may damage the Faucet's finish.
TRIM INSTALLATION
1
Push CAPS (1) over the O-RING SEALS (2).
Push ESCUTCHEON HOLDER (3) with lightly greased O-RING SEAL (4) over CAP (1).
Push on ESCUTCHEON (5) and attach with (60mm) SCREWS (6) to valve body.
2
1
4
3
N
E
P
O
/
P
O
T
1
4
6
5
HANDLE INSTALLATION
2
Push TEMPERATURE-CONTROL KNOB (1) with the red stop onto KNOB MOUNT (2). Push RING (3) onto TEMPERATURE-CONTROL KNOB (1) and attach with SCREW (4).
Push VOLUME-CONTROL KNOB (6) onto HANDLE ADAPTER (8). Push RING (3) onto VOLUME-CONTROL KNOB (6) and and attach with SCREW (7).
Press on KNOB CAPS (5).
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
3
Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:
Shut off water supply. Remove handle and rim Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 4.
TEMPERATURE CALIBRATION
4
Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5). Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE (5).
2
CHECK STOP
(RED TO BLUE)
4
104
1
109
112
8
60
50
2
5
6
3
ARROW
"B"
3
7
5
4
5
CHECK STOP
(BLUE TO RED)
1
ARROW
"A"
3
OPERATING THE VALVE
5
If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed.
If a temperature over 100 F is desired, pull the RED STOP BUTTON (1) away from the body of the MIXER UNIT and turn the TEMPERATURE KNOB.
This will increase the mixed water temperature up to the maximum limit previously selected in step 4.
1
1
0
0
907090-YYY0A
CAP
EN
P
O
/
P
O
T
953961-0070A
ESCUTCHEON CARRIER
918327-0070A
ESCUTCHEON CARRIER SCREWS
953946-YYY0A
ESCUTCHEON
TRIM KIT for CENTRAL
THERMOSTAT
WITH VOLUME CONTROL
MODEL NUMBER
T050.210
954026-YYY0A
VOLUME CONTROL HANDLE BASE
909750-YYY0A
HANDLE RING
918428-0070A
VOLUME CONTROL SCREW
918378-YYY0A
ESCUTCHEON SCREWS
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003
HOT LINE FOR HELP
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
953976-YYY0A
TEMPERATURE CONTROL HANDLE BASE
0
6
0 5
909750-YYY0A
HANDLE RING
060441-YYY0A
TEMPERATURE CONTROL HANDLE
Replace the "YYY" with appropriate finish code
CHROME POLISHED BRASS SATIN CHR/POL. BRASS (MIXAGE)
907065-YYY0A
HANDLE CAP
051313-YYY0A
VOLUME CONTROL HANDLE
918416-0070A
TEMPERATURE SCREW
002 099 295 299