American Standard T028.50X User Manual

Page 1
Installation
Instructions
DAZZLE
BATH AND SHOWER TRIM KITS
Thank you for selecting American-Standard... the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-­please read these instructions carefully before you begin.
Required Tools
T028.50X
ff
O
ot
H
Certified to comply with ANSI A112.18.1
M968834 REV 1.3
Phillips Screwdriver
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note roughing-in dimensions.
FINISHED WALL
5-1/8" REF.
7-7/8" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
Plumbers' Putty or Caulking
1/2" NPT
1-5/8"
to
3-1/4"
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
7-1/8"
Channel Locks
SHR. 1/2" NOM.
COPPER SWEAT
SWEAT INLETS
TUB 1/2" NOM.
COPPER SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM. COPPER SWEAT
3-3/8"
3-3/8"
OUTLETS 1/2" NPT
INLETS 1/2" NOM. COPPER
INLETS
SWEAT
4-1/16"
SWEAT INLETS (STOPS)
5-7/8"
INLETS 1/2" NPT
Teflon Tape
2"
4-1/16"
4-1/16"
INLETS 1/2" NOM. COPPER SWEAT
TOP OF TUB RIM
1-1/2"
REF.
5" REF.
BOTTOM OF TUB
1/2" NPT
THREADED INLETS
OUTLETS 1/2" NPT
5-7/8"
1/2" NPT
4"
3-3/8"
THREADED INLETS (STOPS)
Page 2
INSTALL TRIM
1
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
INSTALL HANDLE
2
Find correct position of HANDLE (1) and push HANDLE (1) onto VALVE STEM (4).
Install HANDLE SCREW (2) and push in INDEX CAP (3).
Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4).
Remove PIPE CAPS (5) from shower pipe and tub filler pipe.
Install SHOWER ARM with FLANGE (6) and SHOWER HEAD (7).
Install SLIP-ON SPOUT with FLANGE (8) and tighten with a 4mm (5/32") HEX WRENCH.
SHOWER ARM FLANGE
6
A
5
2
1
7
4
ff
O
3
Check proper operation of HANDLE (1).
Turn on water supply on and test installed fitting. Operate valve and diverter spout.
ff
O
4
1
2
3
Hot
t
o
H
8
5
SPOUT FLANGE
ADJUST HOT LIMIT STOP
3
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
4mm (5/32") HEX WRENCH.
4
(Larger Numbers)
0 1 3 5 7 9 11 13 15
1
0
1
5
1
3
1
1
9
7
5
3
1
COLDER
3
7
9
5
1
3
1
3
1
5
1
5
1
4
2
3
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
5
1
3
1
1
9
7
5
3
1
1
M968834 REV 1.3
Page 3
TO GAIN ACCESS TO VALVE FOR SERVICING
4
Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.
Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON.
Remove COVER by pulling straight out.
Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5).
Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
6
4
1
8
7
5
3
9
2
LARGE OUTLET
5
INLETS
ROTATE 180˚
BACK TO BACK INSTALLATION
CARE INSTRUCTIONS:
5
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
M968834 REV 1.3
Page 4
M962286-YYY0A
SHOWER ARM AND ESCUTCHEON WITH SEALS
DAZZLE
BATH AND SHOWER TRIM KITS
MODEL NUMBER
T028.50X
M953564-YYY0A
SHOWER HEAD
M907051-YYY0A
CARTRIDGE CAP
078016-YYY0A
ESCUTCHEON SCREWS
Off
ot
H
Replace the "YYY" with appropriate finish code
CHROME 002 SATIN 295
M962293-YYY0A
ESCUTCHEON KIT WITH SCREWS
M916529-YYY0A
LEVER HANDLE
A918657-0070A
HANDLE SCREW
M909732-YYY0A
SPOUT ESCUTCHEON
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc. © AS America, Inc. 2008
HOT LINE FOR HELP
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
M907024-YYY2A
INDEX BUTTON (ARROW)
M950226-YYY0A
DIVERTER SPOUT
M968834 REV 1.3
Loading...