Installation
Instructions
COPELAND
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TRIM KIT
Thank you for selecting American-Standard...the
benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
R510
1/2 NPT
R530
192.6mm
(7-9/16)
3/4 NPT
R510
1/2 NPT
R530
3/4 NPT
T005.730
86mm
(3-3/8)
34mm
(1-3/8)
25mm
(1)
Certified to comply with ANSI A112.18.1M
ASSE 1016
M968014
77mm
(3-1/16)
192.6mm
(7-9/16)
Recommended Tools
Flat Blade Screwdriver
CARE INSTRUCTIONS:
To keep your new faucet looking new, please follow
these simple care instructions:
DO: Simply rinse the faucet clean with clear water.
Dry the faucet with a soft cotton cloth.
DO NOT:
Do not use any abrasive cleaners, cloths, or
paper towels.
Do not use any cleaning agents containing
acids, polish abrasives, or harsh cleaners or
soaps.
Regular and routine cleaning will reduce the need for
heavy cleaning and polishing. If heavy cleaning is
required, the following procedures are recommended:
48mm to 68mm
(2 to 2-5/8)
Phillips Screwdriver
Remove as much surface dirt and film using clear
water and soft cotton cloth
Use any of the following to remove tough surface
film and build-up:
Mild liquid detergents
Clear ammonia free liquid glass cleaners
Non-acidic, non-abrasive gentle liquid or fully
dissolved powder cleansers mixed according to
manufacturers directions.
Non-abrasive liquid polishers
Once clean, rinse faucet again with clear water to
thoroughly remove cleaner or polish and blot dry with
a soft cotton cloth.
(as described above).
Failure to follow these care instructions may
damage the Faucet's finish.
TRIM INSTALLATION
1
Push CAP (1) over the O-RING SEAL (2).
Push ESCUTCHEON HOLDER (3) with lightly greased
O-RING SEAL (4) over CAP (1).
Attach the FIXATION PLATE (7) to the ESCUTCHEON
HOLDER (3) with the two SCREWS (5) provided.
Push ESCUTCHEON (6) flush against finished wall.
2
GREASE ESCUTCHEON
O-RING SEAL
1
3
4
HANDLE INSTALLATION
2
Install HANDLE BASE (1) onto TEMPERATURE CONTROL KNOB (2)
Install HANDLE ADAPTER (3) onto HANDLE BASE (1) and tighten
with SCREW (4).
Align HANDLE (5) and push onto HANDLE ADAPTER (3).
Tighten SET SCREW (6) in handle with HEX WRENCH (7) SUPPLIED.
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
3
Should the hot and cold water supply pipes have been transposed making
adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE
CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 4.
7
1
3
CHECK STOP
(RED TO BLUE)
6
2
4
6
5
7
CHECK STOP
(BLUE TO RED)
TEMPERATURE CALIBRATION
4
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3)
and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109˚F at the factory.
This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the maximum
mixed water temperature to 104˚F or 112˚F.
For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout
temperature is 100˚F. Check that arrow marking A on the KNOB MOUNT (3) still points
upward after adjusting the thermostat to 100˚F. If not, pull out the RED LOCKING DEVICE (5).
Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE (5).
OPERATING THE VALVE
5
Turn on water supply on and test installed fitting.
If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed.
See step 3 for TRANSPOSED SUPPLY PIPING.
Operate valve from off to cold to hot. Check temperature. If max mixed water
temperature is to hot or to cold see step 4 and re-calibrate the valve.
ARROW
"B"
4
104
109
112
1
ARROW
"A"
3
2
5
HOT
COLD
OFF
M968014
M962630-0070A
ESCUTCHEON HOLDER
A924335-0070A
FIXATION PLATE
COPELAND
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TRIM KIT
MODEL NUMBERS
T005.730
M907593-YYY0A
ESCUTCHEON KIT
A907090-YYY0A
CAP
023774-0070A
ESCUTCHEON SCREWS
Replace the "YYY" with
appropriate finish code
CHROME
BLACKENED BRONZE
SATIN NICKEL
M916586-YYY0A
HANDLE BASE
M918053-0070A
ADAPTER
M918349-0070A
SELF TAPPING SCREW
M962729-YYY0A
HANDLE KIT
002
068
295
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
HOT LINE FOR HELP
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
M968014