Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" FOR HEAD 
CLEARANCE
4-1/4" REF.
1-5/8" TO 3" 
18" OPTIONAL
4-7/8" REF.
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-1/2"
1-1/2"
6" REF.
OPTIONAL TO FINISHED 
FLOOR USUALLY 
BETWEEN 65'' AND 78'
"SEE ILLUSTRATION "
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions. 
PRESSURE BALANCING BATH 
AND SHOWER TRIM KITS
COPELAND
Installation
Instructions
T005.5XX
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS 
1/2" NPT
OUTLETS 
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM. 
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS 
1/2" NOM. 
COPPER 
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT 
INLETS
SWEAT 
INLETS (STOPS)
INLETS 
1/2" NOM. 
COPPER 
SWEAT
M968636 Rev 1.1
Thank you for selecting American-Standard...the benchmark 
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please 
read these instructions carefully before you begin.
 

M968636 Rev 1.1 M968636 Rev 1.1 M968636 Rev 1.1
7
8
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2. Figure 3.
3
5
6
4
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1) 
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1) 
and attach with LONG SCREWS (4). Mount ESCUTCHEON 
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT 
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8) 
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5) 
and press ESCUTCHEON (8) flush against finished wall. 
PLSTER 
GUARD
9
5
PIPE 
PLUG
PIPE 
CAP
1
4
3
2
SHR. 
ELBOW
TUB FILLER 
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub 
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with 
4mm Hex Wrench.
CAUTION: Protect finish on TUB SPOUT when 
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER 
ARM (3). Apply sealant or Teflon tape to threads on 
both ends of SHOWER ARM (3) and thread longer 
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
2
INSTALL TUB SPOUT, SHOWER HEAD, 
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and 
ARM when installing.
CAUTION: Protect finish on SHOWER 
HEAD and TUB SPOUT when installing.
4MM HEX 
WRENCH
 

SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets 
and MANIFOLD (5). 
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). 
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off" 
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full 
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount 
of hot water allowed to mix with the cold, the HOT LIMIT 
SAFETY STOP reduces risk of accidental scalding. To set 
the maximum hot water temperature of your faucets, all 
you need to do is adjust the setting on the HOT LIMIT 
SAFETY STOP. 
Use a flat blade screwdriver or your fingers to pull 
up and rotate red HOT LIMIT SAFETY STOP (1). 
Follow Step "A" or "B" to adjust min./max. discharge 
temperature. "0" being the hottest to "7" the coldest 
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE 
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT 
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX 
WRENCH
4
HANDLE INSTALLATION
3
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2) 
and tightening SET SCREW (3) from below with 2.5mm 
Hex Wrench supplied.
2
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A 
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
 

PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
M962606-YYY0A
SHOWER ARM
AND FLANGE
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
M953579-YYY0A
SHOWER HEAD
T005.5XX
COPELAND
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
M962607-YYY0A
HANDLE
M962427-0070A
ESCUTCHEON HOLDER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369  (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr od uct n ame s li ste d her ei n are t rad em ar ks of  Am er ic an St and ar d Inc . 
© Am eri ca n S ta nd ard I nc. 2 00 7
IN MEXICO 01-800-839-12-00
CHROME 
SATIN NICKEL 
BLACKENED BRONZE   
002 
295 
068
Replace the "YYY" with 
appropriate finish code