American Standard Pressure Balancing Bath and Shower Trim, T508.50X User Manual

Installation
PRINCETON
PRESSURE BALANCING
Instructions
T508.50X
BATH AND SHOWER TRIM KITS
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-- please read these instructions carefully before you begin.
RECOMMENDED TOOLS
Phillips Screwdriver
Plumbers' Putty or Caulking
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
3-5/8" REF.
5-1/2" REF.
4-7/8" REF.
Teflon Tape
1-5/8" TO 3-1/4"
1/2" NPT
Flat Blade Screwdriver
SHR. 1/2" NOM.
COPPER SWEAT
SWEAT INLETS
TUB 1/2" NOM.
COPPER SWEAT
INLETS
4-1/16"
Adjustable Wrench
INLETS 1/2" NOM. COPPER SWEAT
2"
4-1/16"
Certified to comply with ANSI A112.18.1
M968841 REV. 1.4
Channel Locks
74" FOR HEAD CLEARANCE
18" OPTIONAL
FINISHED
8-1/2" REF.
"SEE ILLUSTRATION "
1-1/2" REF.
5-1/8" REF.
TOP OF TUB RIM
BOTTOM OF TUB
OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 78'
6-3/4"
1/2" COPPER
4"
INLETS 1/2" NPT
3-3/8"
3-3/8"
OUTLETS 1/2" NPT
THREADED INLETS
SWEAT INLETS (STOPS)
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM. COPPER SWEAT
3-3/8"
5-7/8"
4-1/16"
INLETS 1/2" NOM. COPPER
OUTLETS 1/2" NPT
SWEAT
5-7/8"
1/2" NPT
THREADED INLETS (STOPS)
INLETS
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
INSTALL TRIM
1
When finished tiling the wall, remove PLASTER GUARD (3). Push on CAP (1).
Mount ESCUTCHEON (2) and with SCREWS (7).
4
5a
3
Install HANDLE (8) by pushing it onto CARTRIDGE STEM (9) and tightening SET SCREW (10) from below with 2.5mm
5
Hex Wrench supplied. Insert INDEX BUTTON (11).
Remove cap from tub supply and plug from shower pipe.
2
9
Install SHOWER ARM with FLANGE (4) and SHOWER HEAD (5, 5a).
Install DIVERTER SPOUT (6).
1
7
8
10
11
6
ADJUST HOT LIMIT STOP
2
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
"A"
ADJUSTMENT WHEN WATER IS TOO HOT
TEMPERATURE SETTING NUMBERS
"B"
ADJUSTMENT WHEN WATER IS TOO COLD
PRY RED RING FORWARD AND ROTATE CLOCKWISE
"B"
0
1
2
3
4
5
6
"A"
PRY RED RING FORWARD AND ROTATE
COUNTER-CLOCKWISE ONE CLICK
SERVICE
3
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.
1
"RED RING"- HOT LIMIT SAFETY STOP
4
5
1
2
3
M968841 REV. 1.4
Loading...