Installation
Instructions
ONE
T064.60X
BATH/SHOWER TRIM KIT WITH DIVERTER
Congratulations on purchasing your American Standard faucet with EverClean™ finish a features found oniy on American Standard faucets.
• One wipe effortlessly removes spots.
• Eliminates the need for cleaners and scrubbing.
• Permanent surface protectant remains beautiful
for the life of the faucet.
• EverClean™ available on: Polished Chrome, Satin Nickel, Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required Tools
Flat Blade Screwdriver
Pipe Wrench
ROUGHING-IN DIMENSIONS
■ To assure proper positioning in relation to wall, note
roughing-in dimensions.
Phillips Screwdriver Plumbers' Putty or Caulking Adjustable Wrench
-►M-5/8" TO 3-1/4"
Certified to compiy with ANSI A112.18.1
M968836
Channel Locks
5-5/8" REF.
74"FOR
HEAD CLEARANCE
OPTIONAL
FINISHED WALl^
18"
TOP OF^ TUB RIM \
BOTTOM OF
f
8-1/8" REF.
7-1/4" □. ac
h
-----
8-3/4"-
TUB
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
80" AND 86'
4-'
"SEE ILLUSTRATION"
1/2" NPT
1/2" REF.
4"
^ OUTLETS 1/2" NPT
INLETS
1/2" NPT
THREADED INLETS (STDPS)
Page 2
INSTALL DIVERTER
When finished tiling the wall, remove PLASTER GUARD (1). Remove two screws that secure the DIVERTER LID (2) and remove Lid. Inspect the inside surface of diverter port. Diverter port must be free of any dirt. Clean if necessary.
Install DIVERTER (3) with SCREWS (4) removed with DIVERTER LID (2).
Operate DIVERTER (3). DIVERTER (3) should slide in and out smoothly.
INSTALL VALVE TRIM
DIVERTER
PORT
Figure 1. Push CAP (1) over VALVE CARTRIDGE (2) until
seated against stop. Push CAP (3) over DIVERTER (4) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (5) onto CAP(1J
and attach with SCREWS [S). Mount ESCUTCHEON SUPPORT (7J to ESCUTCHEON HOLDER (5) with SCREWS (8).
Figure 3. Align PINS (10) on back side of ESCUTCHEON (11)
with the FOUR HOLES (12) in ESCUTCHEON SUPPORT (7) and press ESCUTCHEON (11) flush against finished wall.
Figure 1.
Figure 2.
M968836
Page 3
ADJUST HOT LIMIT STOP
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP 11J reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP llj.
Turn CARTRIDGE STEM (2) to the OFF position [coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1J. Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1J for indication.
(Larger Numbersl
□ 1 3 5 719 11 13 15l
INSTALL HANDLE, DIVERTER KNOB, TUB
O
SPOUT AND SHOWER
■ Thread DIVERTER KNOB (1) onto diverter stem.
■ Hold ADAPTER (2) onto VALVE STEM (3) and install
ADAPTER SCREW (4) through ADAPTER (2) into VALVE STEM (3J.Tighten ADAPTER SCREW (4) to secure ADAPTER (2) to VALVE STEM (3).
■ Install HANDLE BASE (5) onto ADAPTER (2). Insert SET SCREW (S) into HANDLE BASE (5). Align
HANDLE BASE (4) and tighten with HEX WRENCH
(7) supplied.
■ Thread LEVER HANDLE (8) into HANDLE BASE (5).
■ Remove pipe cap and plug from shower and tub rough piping.
■ Install SPOUT ESCUTCHEON (8) onto TUB SPOUT IIO).
■ Apply sealant or Teflon tape to threads of tub filler nipple. Thread TUB SPOUT (10) onto tub nipple.
■ Install SHOWER ESCUTCHEON (11) onto SHOWER
ARM (12). Apply sealant or Teflon tape to threads on both ends of SHOWER ARM (12) and thread longer leg of SHOWER ARM (12) into shower elbow.
■ Thread SHOWER HEAD (13) onto SHOWER ARM (12).
CAUTION: Protect finish on SHOWER HEAD and ARM when installing.
TO GAIIM ACCESS TO VALVE FOR SERVICING
Unthread LEVER HANDLE, loosen SET SCREW and pull HANDLE off valve stem. To remove Escutcheon assembly reverse steps in Step 3.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull
out PRESSURE BALANCING (5) unit. Clean SEALS (S) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean 0-RINGS (6). Remove CAPS (7J and check D-RINGS on inside of CAPS (7J. Clean inside sealing surfaces of VALVE BODY (8). Reessemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1J.
Tighten all screws. Turn on water supply and see above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly. Examine balancing unit and check condition of 0-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective. Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 1 B0‘ so that the inlets face up and the large outlet port faces down. Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE HJ.
ROTATE 180'
SHR.
ELBOW
BACK TO BACK INSTALLATION
M968836
Page 4
Лмпст Skmia^xl
M9G2818-YYY0A
DEEP ROUGH KIT
(NOT SHOWN]
ONE
BATH/SHOWER TRIM KIT
WITH DIVERTER
MODEL NUMBER
T064.60X
M982493-YYY0A
SHOWER ARM & FLANGE
M953540-YYY0A
SHOWER HEAD
M962494-0070A
ESCUTCHEON HOLDER
Replace the "YYY" with appropriate finish code
CHROME GG2 SATIN NICKEL
295
M907053-YYY0A -
CAP
M962495-YYY0A
TUB SPOUT ESCUTCHEON
M918039-0070A-
HANDLE ADAPTER
M962209-YYY0A
SPOUT KIT
M9G242G-YYY0A-
HANDLE KIT
A950849-YYY0A
ESCUTCHEON WITH DIVERTER
M909917-YYY0A
DIVERTER KNOB
I—A918477-0070A
HANDLE SCREW
922388-YYYOA
STREAM STRAIGHTENER
For toll-free Informetlon end enswers to your questions, cell:
IN CANADA 1-800387-0389 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2006
HOT LINE FOR HELP
1 [800)442-1902
Weekdays 8:00 e.m. to 8:00 p.m. EST
IN MEXICO 01-800939-12-00
Weekdays 8:00 e.m. to 7:00 p.m. EST