Installation
Instructions
MOMENTS
T506.50X
BATH/SHOWER TRIM KIT
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Recommended Tools
Flat Blade Screwdriver
Pipe Wrench
Phillips Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note
roughing-in dimensions.
FINISHED WALL
5-5/8" REF.
2-3/8"
8-1/8" REF.
"SEE ILLUSTRATION "
74" FOR
HEAD CLEARANCE
8-3/8"
18"
OPTIONAL
6-1/2"
3/4"" TO 2-3/8"
1/2" NPT
SHR
TUB
Plumbers' Putty or Caulking
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
SWEAT
INLETS (STOPS)
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
INLETS 1/2" NPT
3-3/8"
SWEAT
INLETS
Adjustable Wrench
INLETS
4-1/16"
5-7/8"
Certified to comply with ANSI A112.18.1
M968951 Rev. 1.4
Channel Locks
INLETS
1/2" NOM.
COPPER
SWEAT
2"
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
OUTLETS
1/2" NPT
5-7/8"
TOP OF
TUB RIM
1/2" NPT
1-1/2" REF.
4"
BOTTOM OF
TUB
3-3/8"
OUTLETS
1/2" NPT
THREADED INLETS
3-3/8"
INLETS
1/2" NPT
THREADED INLETS (STOPS)
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

INSTALL VALVE TRIM
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8)
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5)
and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
Figure 1.
9
5
1
3
5
4
Figure 2. Figure 3.
6
1
2
7
8
INSTALL TUB SPOUT, SHOWER HEAD,
2
SHOWER ARM WITH FLANGE
Remove pipe cap and plug from shower and tub
rough piping.
Install SPOUT ESCUTCHEON (1) onto TUB SPOUT (2).
Apply sealant or Teflon tape to threads of tub filler
nipple. Thread TUB SPOUT (2) onto tub nipple.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (3) onto SHOWER
ARM (4). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (4) and thread longer
leg of SHOWER ARM (4) into shower elbow.
Thread SHOWER HEAD (5) onto SHOWER ARM (4).
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
3
4
5
SHR.
ELBOW
PIPE
PLUG
2
TUB FILLER
NIPPLE
1-1/2" REF.
2
1
M968951 Rev. 1.4

ADJUST HOT LIMIT STOP
3
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
1
"A"
ADJUSTMENT WHEN
FORWARD AND ROTATE
COUNTER-CLOCKWISE
"A"
WATER IS TOO HOT
PRY RED RING
ONE CLICK
TEMPERATURE
SETTING
NUMBERS
"RED RING"- HOT
LIMIT SAFETY STOP
"B"
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
HANDLE INSTALLATION
4
INSTALL HANDLE ADAPTER
Push HANDLE ADAPTER (1) onto VALVE STEM (2).
Tighten set screw (3) with 2.5mm hex wrench
supplied.
2
1
3
2.5MM HEX
WRENCH
4b
INSTALL ADPATER
With a flat blade screwdriver thread ADAPTER (5)
onto SET SCREW (4) and tighten.
4a
INSTALL ADAPTER SCREW
With a flat blade screwdriver thread ADAPTER SCREW (4) into
HANDLE STEM ADAPTER (1) and tighten.
1
4
4c
INSTALL HANDLE
Align HANDLE (6) and install onto
HANDLE ADAPTER ASSEMBLY (7).
Tighten set screw (8) with 2.5mm
hex wrench supplied to secure HANDLE.
Push PLUG BUTTON (9)
into set screw access hole
in HANDLE (6).
7
5
4
SERVICE
5
If faucet drips, operate handle several times
from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced
flow in "full on" hot or cold. To clean inlets, first turn
off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4).
Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
6
CARTRIDGE
INLETS
8
9
2.5MM HEX
WRENCH
5
4
3
2
1
M968951 Rev. 1.4