FEATURES
American Standard sells comfort systems. Comfort is achieved through matching the correct equipment and controls. This thermostat is designed to provide the maximum comfort for your needs. Some of the basic offerings are:
Simple and easy to use. The and keys make it easy for you to change your temperature
setting.
Large digital display. You can easily read the current room temperature at a glance.
No need for batteries. Batteries are not required because your temperature settings are held permanently in memory.
2
Pub. No. 12-5018-01
69-1324
SETTINGS
Setting SYSTEM and FAN Switches
System and fan settings are controlled by using SYSTEM and FAN switches located on the bottom of the thermostat case.
First set the SYSTEM switch:
Cool: Normal setting for months when your
home needs cooling (air condition­ing). Digital display shows a snowflake when cooling is on.
Off: Both heating and cooling are off. Heat: Normal setting for months when your
home needs heating. Digital display shows a flame when heating is on.
Em. Ht.: Switch to this setting when your
home needs heat, but your equip­ment needs servicing or is not working properly. In this mode, the thermostat controls only the backup heat. The heat pump is off.
SYSTEM
Cool Off Heat Em.Ht.
SYSTEM SWITCH
3
Pub. No. 12-5018-01
M10274
69-1324
Then set the FAN switch:
Auto: Normal setting for most homes.
On: The fan runs continuously. Use for
Some systems may delay the fan turning on and off with the equip­ment.
improved air circulation and air quality.
FAN
Auto On
FAN SWITCH
M10273
Emergency Heat
The Emergency Heat feature allows you to “turn on” the electric heat section of the system by moving the system switch to the Em. Ht. position. The indicator flashes and
points to Em Ht when the system is in emergency heat mode. The
indicator may
also point to Aux Ht if the system calls for additional back-up heating.
INDICATOR
Em Ht Aux Ht
Set
Room
M10287
Auxiliary Heat
The auxiliary heaters assist the heat pump under normal conditions when low outdoor temperature occurs. The Aux Ht when the auxiliary heating equipment operates.
indicator points to
4
Pub. No. 12-5018-01
69-1324
Displaying Temperature Setting
NOTE: Your temperature setting can be set
The temperature setting and the room temperature display separately. The indicator points to Set when the temperature setting displays, and to Room when the room temperature displays. The thermostat displays room temperature unless or is pressed.
anywhere from 50° to 99°F (10° to 37°C).
1. To display the temperature setting on
the digital display, press either the ▲ or key once.
Set
Room
INDICATOR
M10275
Changing Temperature Setting
1. To lower the temperature setting, press
the key. When in the heating mode, lowering the temperature at night or during the day can lower your energy costs.
Set
Room
M10276
5
Pub. No. 12-5018-01
69-1324
2. To raise the temperature setting, press
the key. When in the cooling mode, raising the temperature before you leave for work or school also lowers your energy costs.
Set
Room
M10277
CAUTION
Equipment Damage Hazard. Can cause permanent damage to the compressor or other equipment.
To avoid possible equipment damage, do not operate cooling when outside temperature is below 50°F (10°C). See equipment manufacturer instruc­tions. To avoid possible compressor damage, allow the compressor to remain off for five minutes before restarting.
6
Pub. No. 12-5018-01
69-1324
TROUBLESHOOTING GUIDE
Symptom Action
Heating or Cooling will not come on.
Temperature setting is too warm or cool.
Check that the SYSTEM switch on the thermostat is set to Heat or Cool. Check if the circuit breaker is tripped—reset the circuit breaker. Check if the fuse is blown—replace the fuse. Check for air movement at the register. Check power to the heating or cooling equipment.
Adjust the temperature by pressing either the or key.
7
Pub. No. 12-5018-01
69-1324
LIMITED WARRANTY
Low Voltage Room Thermostats
This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Thermostat is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada.
If any part of your Thermostat fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will furnish, without charge, a new thermostat. Any local
transportation, related service labor and diagnosis calls are not included.
This warranty does not cover failure of your Thermostat if it is damaged while in your posses­sion or if the failure is caused by unreasonable use. In no event shall Warrantor be liable for incidental or consequential damages. In no event shall any implied warranty of merchandise
or fitness for use exceed the terms of the limited warranty stated above.
8
Pub. No. 12-5018-01
69-1324
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Parts will be provided by our factory organization or an authorized service organization in your area. All you need to do is look us up in the Yellow Pages or write to the address given below. If you wish further help or information concerning this warranty, contact:
American Standard Inc. Troup Highway Tyler, TX 75711-9010 Attention: Manager, After Sales Support
9
Pub. No. 12-5018-01
69-1324
CUSTOMER ASSISTANCE
For service, or answers to your questions, contact your local heating and cooling contractor.
10
Pub. No. 12-5018-01
69-1324
11
Pub. No. 12-5018-01
69-1324
Pub. No. 12-5018-01
H E A
T I N G & A I R
C O N D I
T I O N I N G
® U.S. Registered Trademark 69-1324 7-99 G.H. Printed in Mexico
H E A
T I N G & A I R
C O N D I
T I O N I N G
American Standard Inc. Troup Highway T yler , TX 75711-9010
Loading...