American Standard 6062.025, 6061.013, 6062.051, 6062.101, 6061.025 Installation Instructions Manual

...
Installation Instructions
SELECTRONIC
®
HARD-WIRED AC POWERED PROXIMITY URINAL FLUSH VALVE
0.125 0.25 0.5 & 1.0 GPF
Exposed Flushometer for 3/4" Top Spud Urinals
MODEL NUMBERS
6062.013
6062.025
6062.051
6062.101
6061.013
6061.025
6061.051
6061.101
Certified to comply with ASME A112.19.2M
© 2011 AS America, Inc.
Installation Instructions
M965218 REV 1.8
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l ea r n m or e ab ou t A me r ic an S ta nd ar d Fa uc e ts vi si t o ur we bs it e at : www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
Ins t a lla t i on I n str u c t io n s
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
8.
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
Supply Stop
9.
Installation Instructions
10.
Front Panel
11.
Power Supply
12.
10' Extension Cable for Multi-AC (6061.013, .025, .051, .101)
13.
Cable Extension, 27"
14.
Y Connector (6061.013, .025, .051, .101)
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
6
5
1
7
8
10
2
3
4
13
11
12
14
9
SELECTRONIC
HARD-WIRED AC POWERED PROXIMITY URINAL FLUSH VALVE
0.125 0.25 0.5 & 1.0 GPF
Certified to comply with ASME A112.19.2M
© 2011 AS America, Inc.
Installation Instructions
M965218 REV 1.8
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l e a rn m or e a b o ut A m e ri c a n S ta n d ar d F a uc e ts v is i t o u r w eb s i te at : www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
®
Exposed Flushometer for 3/4" Top Sp ud U ri n al s
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
MODEL NUMBERS
6062.013
6062.025
6062.051
6062.101
6061.013
6061.025
6061.051
6061.101
1
M965218 REV 1.8
Fig. 1
Roughing-in Dimensions
180
˚
Right or Left Hand Installation
See (Section 7) for converting Flush Val ve to Le ft Han d I nst all ati on.
116mm
MANUAL
OVERRIDE
BUTTON
293mm
(11-1/2")
(4-5/8")
*CRITICAL
LEVEL
-C-L-
152mm
(6") MIN.
72mm
(2-7/8")
-C-L-
305mm
(12" MAX.)
115mm - 134mm (4-1/2") - (5-1/4")
FOR 3/4" TOP SPUD FIXTURES
86mm (3-3/8)
SUPPLY DN 20mm (3/4" I.P.S.)
45
˚
409mm
(16-1/8")
SEE DETAIL “A”
51mm (2") HOLE FOR CONDUIT
FINISHED WALL
DETECTION ZONE
400mm-800mm
(15-3/4" TO 31-1/2")
NOTE: INSTALL PLASTER
RING SO THAT SCREW HOLES ARE ON THE LEFT AND RIGHT SIDE OF BOX.
57mm - 76mm (2-1/4") - (3")
15˚
FINISHED WALL
OPENING
GENERAL DESCRIPTION:
SELECTRONIC™ PROXIMITY TOILET FLUSH VALVE
Exposed Flushometer for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on AC power. Recommended operating pressure 20psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.
4" (102 mm) SQ. BOX DEVICE COVER (PLASTER RING)
3/4" (19 MM) HIGH Hubbel-RACO #779 OR EQUAL
OPTIONAL: w/Appleton #4SDI or EQUAL OUTLET BOX.
FINISHED TILE WALL
(BY CONTRACTOR).
DETAIL “A”
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
fixture. Consult Codes for details.
" (152mm) above
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring must be installed in accordance with applicable codes, regulations and standards.
• The use of water hammer arrestors is strongly recommended for commercial applications. All piping behind the walls should be properly secured and fastened.
• Water supply lines must be sized to provide an adequate volume of water for each fixture.
FINISHED PLASTER WALL
4" (102mm) SQ. X 2-1/8" (54mm) DEEP ELECTRICAL BOX
Hubbel-RACO #8231 OR EQUAL (BY CONTRACTOR).
4" (102mm) SQ. X 2-1/2" (64mm) DEEP OUTLET BOX
APPLETON #4SDI OR EQUAL (BY CONTRACTOR).
OR
Fig. 2
1
2
4
10'
3
6
5
8
7 9 10
• Flush all water lines prior to operation (See Step 6). Dirt and debris can cause flush valve to run continuously.
With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special finish on the Flushometer. DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.