![](/html/6d/6d47/6d47db5a168237feff4bf99fbfa22dcec103bba1c270f8a7414b00f846ef4c2f/bg1.png)
Installation Instructions
SELECTRONIC
®
HARD-WIRED AC POWERED PROXIMITY
URINAL FLUSH VALVE
0.125 0.25 0.5 & 1.0 GPF
Exposed Flushometer
for 3/4" Top Spud Urinals
MODEL NUMBERS
6062.013
6062.025
6062.051
6062.101
6061.013
6061.025
6061.051
6061.101
Certified to comply with ASME A112.19.2M
© 2011 AS America, Inc.
Installation Instructions
M965218 REV 1.8
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l ea r n m or e ab ou t A me r ic an S ta nd ar d Fa uc e ts vi si t o ur we bs it e at : www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
![](/html/6d/6d47/6d47db5a168237feff4bf99fbfa22dcec103bba1c270f8a7414b00f846ef4c2f/bg2.png)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
Ins t a lla t i on I n str u c t io n s
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after they
have been removed from the carton. Some items may be packaged partially assembled to other items.
8.
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
Supply Stop
9.
Installation Instructions
10.
Front Panel
11.
Power Supply
12.
10' Extension Cable for Multi-AC (6061.013, .025, .051, .101)
13.
Cable Extension, 27"
14.
Y Connector (6061.013, .025, .051, .101)
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR
EYE UNTIL INSTALLATION IS COMPLETE.
6
5
1
7
8
10
2
3
4
13
11
12
14
9
SELECTRONIC
HARD-WIRED AC POWERED PROXIMITY
URINAL FLUSH VALVE
0.125 0.25 0.5 & 1.0 GPF
Certified to comply with ASME A112.19.2M
© 2011 AS America, Inc.
Installation Instructions
M965218 REV 1.8
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l e a rn m or e a b o ut A m e ri c a n S ta n d ar d F a uc e ts v is i t o u r w eb s i te at : www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
®
Exposed Flushometer
for 3/4" Top Sp ud U ri n al s
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
MODEL NUMBERS
6062.013
6062.025
6062.051
6062.101
6061.013
6061.025
6061.051
6061.101
1
M965218 REV 1.8
![](/html/6d/6d47/6d47db5a168237feff4bf99fbfa22dcec103bba1c270f8a7414b00f846ef4c2f/bg3.png)
Fig. 1
Roughing-in Dimensions
180
˚
Right or Left Hand Installation
See (Section 7) for converting Flush
Val ve to Le ft Han d I nst all ati on.
116mm
MANUAL
OVERRIDE
BUTTON
293mm
(11-1/2")
(4-5/8")
*CRITICAL
LEVEL
-C-L-
152mm
(6") MIN.
72mm
(2-7/8")
-C-L-
305mm
(12" MAX.)
115mm - 134mm
(4-1/2") - (5-1/4")
FOR 3/4" TOP
SPUD FIXTURES
86mm
(3-3/8)
SUPPLY
DN 20mm
(3/4" I.P.S.)
45
˚
409mm
(16-1/8")
SEE DETAIL “A”
51mm (2") HOLE
FOR CONDUIT
FINISHED WALL
DETECTION ZONE
400mm-800mm
(15-3/4" TO 31-1/2")
NOTE: INSTALL PLASTER
RING SO THAT SCREW
HOLES ARE ON THE LEFT
AND RIGHT SIDE OF BOX.
57mm - 76mm
(2-1/4") - (3")
15˚
FINISHED WALL
OPENING
GENERAL DESCRIPTION:
SELECTRONIC™
PROXIMITY TOILET
FLUSH VALVE
Exposed Flushometer
for 3/4" Top Spud Fixtures
Exclusive, self cleaning piston-type
flush valve with proximity operation
and manual override. Operates on
AC power. Recommended operating
pressure 20psi (flowing) to 80 psi
(static). Can install left or
right-handed. Detection Zone can
also be adjusted manually, or with
optional remote control.
4" (102 mm) SQ. BOX DEVICE COVER (PLASTER RING)
3/4" (19 MM) HIGH Hubbel-RACO #779 OR EQUAL
OPTIONAL: w/Appleton #4SDI or EQUAL OUTLET BOX.
FINISHED TILE WALL
(BY CONTRACTOR).
DETAIL “A”
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
" (152mm) above
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring must be installed in
accordance with applicable codes, regulations and
standards.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
FINISHED PLASTER WALL
4" (102mm) SQ. X 2-1/8" (54mm) DEEP ELECTRICAL BOX
Hubbel-RACO #8231 OR EQUAL (BY CONTRACTOR).
4" (102mm) SQ. X 2-1/2" (64mm) DEEP OUTLET BOX
APPLETON #4SDI OR EQUAL (BY CONTRACTOR).
OR
Fig. 2
1
2
4
10'
3
6
5
8
7 9 10
• Flush all water lines prior to operation (See Step 6). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
2
M965218 REV 1.8