American Standard 6060.028WC User Manual

CADENZA™ WHIRLPOOL
6060.028WC Whirlpool featuring System II
• EverClean® System
• Pre-leveled tub bottom
• Two person design with center drain and dual lumbar ends
• Molded-in seat
• Wave style grab bar
• 2.1 HP, two speed, self-draining pump/motor with pulse feature
• Factory installed power cord and plug
• Ten multi-directional and ow-adjustable jets including:
- Two Ideal-ow jets
- Six body massage jets
- Two recessed back-rest jets
• Deck-mounted electronic control with 20 minute built-in timed safety shut off and Chrome Bezel
• Three silent air volume controls
• Factory installed Safe-T-Heater™ Whirlpool Heater
• Factory installed and tested whirlpool system
Nominal Dimensions: 1384 x 1384 x 546mm (54-1/2" x 54-1/2" x 21-1/2")
Compliance Certications ­Meets or Exceeds the Following Specications:
• Underwriters Laboratories - Hydromassage Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
CADENZA™
WHIRLPOOL
HIGH GLOSS
To Be Specied - Required:
Color: Bath Filler: (specify nish) Bath Drain: 1583.470 (specify nish)
To Be Specied - Optional:
Universal Tile Bead Kit: 751755-100 Corner Apron: 0707.200 (specify color) System II Control Bezel: 9861.100 (specify nish)
American Standard whirlpools and air baths with EverClean® incorporate a patented silver-ion additive right into the circulation piping to protect the pipes from mold, mildew, algae and fungus that could cause deterioration or staining of the pipes.
SEE REVERSE FOR PRODUCT DIMENSIONS AND SPECIFICATIONS
© 2008 AS America Inc.
For color/nish availability and other faucet choices, please see the Product Selector and Pricing Guide.
* NOTE: Safe-T-Heater™ is designed to maintain water temperature during operation. It will not heat cold water to desired bathing temperature.
H39
Revised 2/08
1949mm
(76-3/4 REF.)
546mm (21-1/2)
ROUGH FLOOR
495mm (19-1/2)
1384mm
(54-1/2)
1605mm
(63-3/16)
975mm (38-3/8)
1661mm
(65-3/8)
346mm (13-5/8)
SEAT AREA
254mm
(10)
114mm
(4-1/2)
PROVIDE ACCESS TO PUMP FOR SERVICE
ON ALL INSTALLATIONS
NOTE: APRON ASSEMBLY WILL PROVIDE REQUIRED
ACCESS FOR SERVICING
51mm (2)
89mm
(3-1/2)
C/L OF OVERFLOW
LEVELING STRINGER NOT FOR SUPPORT
PUMP
178mm x 381mm (7 x 15) CUTOUT
C/L OF DRAIN
143mm
(5-5/8)
OUTLINE OF
CUTOUT
C/L
ON/ OFF SWIT CH
83mm
(3-1/4)
1-1/2 N.P.T. THREAD
1-1/2 O.D. TAILPIECE
38mm (1-1/2)
INTEGRAL FEET SUPPORT
RECOMMENDED FITTING LOCATION 64 X 381mm (2-1/2 X 15)
E-Z-Install™ HEATER
INS TA LL ED S IZ E WEI GH T WEI GH T w/ WA TE R GAL . TO O VE RF LO W WHI RL PO OL M IN . OPERA TI NG V OL . BAT HI NG W EL L AT SUMP BAT HI NG W EL L AT RIM WAT ER D EP TH T O OVERF LO W FLO OR L OA DI NG (PR OJ EC TE D AR EA ) PTS .
CUBE (FT3)
GENERA L SPECI FICATI ONS FO R 6060 WHIRL POOL
WHIRLP OOL ELE CTRICA L SPEC IFICAT IONS
SYS TE M II P UM P
76- 3/ 4 x 65 -3 /8 x 21 -1 /2 I n. ( 19 49 x 16 61 x 5 46 mm )
105 L bs . (4 8 Kg .)
822 L bs . (3 70 K g.)
86 Ga l. ( 32 6 L)
71 Ga l. ( 26 9 L) 45 x 40 I n. ( 11 43 x 10 16 mm ) 49 x 43 I n. ( 12 45 x 10 92 mm )
15- 3/ 8 In . (3 91 mm)
24 Lb s. /S q. Ft . (114 Kg s. /S q. m)
41. 7
68. 4
2 .1 H P, 1 5. 6 AMPS, 12 0V .
CADENZA™
WHIRLPOOL
HIGH GLOSS
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA T YPE INSTALLATION. SUP­PORT OF BATH BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
OPTIONAL 2-WALL TILING BEAD KIT No.751755-100 MUST BE ORDERED SEPARATELY.
CUTOUT TEMPL ATE PROVIDED IN SHIPPING BOX. MAY BE REQUESTED SEPARATELY.
© 2008 AS America Inc.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
FITTINGS NOT INCLUDED, MUST BE ORDERED SEPARATELY.
IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING
SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.
H40
Revised 2/08
Loading...