PRIOLO 16-1/2" HEIGHT 1.28 GPF
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.
• Floor mount rear outlet ushometer valve toilet
• Vitreous china
• Meets denition for HET (High Efciency Toilet)
• High Efciency (4.8 Lpf/1.28 gpf)
• EverClean® surface inhibits the growth of
stain- and odor-causing bacteria, mold,
and mildew on the surface
• 16-1/2" rim height for accessible application
• Condensation channel
• Elongated bowl
• Powerful direct-fed siphon jet action
• Fully glazed 2-1/8" trapway
• 1-1/2" inlet spud
• 2 bolt caps
• 100% factory ush tested
❏ 3695.128 Elongated bowl only, top spud
❏ 3697.128 Elongated bowl only, back spud
❏ 3696.128 Elongated bowl only, top spud with
slotted rim for bedpan holding (White only)
❏ 3698.128 Elongated bowl only, back spud with
slotted rim for bedpan holding (White only)
PRIOLO 16-1/2" HEIGHT
1.28 GPF FLUSHOMETER TOILET
Component Parts:
❏ 047007-0070A Inlet spud (furnished with bowl)
❏ 481310-100 Bolt caps with retainers
(furnished with bowl)
Nominal Dimensions:
752 x 356 x 438mm
(29-5/8" x 14" x 17-1/4")
Recommended working pressure–between
25 psi at valve when ushing and 80 psi static
Fixture only, less seat and ushometer valve
Compliance Certications Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
• CAN/CSA International B45
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specied:
❏ Color: ❏ White ❏ Bone ❏ Linen
❏ Seat:
❏ American Standard #5901.100 Heavy duty open
front less cover
❏ American Standard #5905.100 Extra heavy duty
open front less cover
❏ Alternative Seat:
❏ Olsonite #95 open front seat less cover
❏ Church #9500C open front seat less cover
❏ Flushometer Valve:
❏ American Standard Selectronic™ #6065.121.002
DC Power (Top Spud)
❏ American Standard Selectronic™ #6065.221.007
DC Power (Back Spud)
❏ American Standard Selectronic™ #6067.221.007
AC Power (Back Spud)
❏ American Standard Selectronic™ #6068.221.007
Multi AC Power (Back Spud)
HET High Efficiency Toilet (1.28gpf/4.8Lpf)
© 2008 AS America Inc.
M67
Revised 11/08
730mm
(28-3 /4)
121mm
(4-3/ 4)
240mm
(9-1/ 2)
152mm
(6)
102mm
(4)
419mm
(16-1 /2)
470mm
(18-1 /2)
356mm
(14)
13mm
(1/2)
345mm
(13-5 /8)
646mm
(25-3 /8)
60m m
(2- 3/8)
136 mm
(5- 3/8)
752 mm
(29 -5/8)
C/L O F SEAT PO ST HOLES
140mm (5-1/2) CENTERS
FINIS HED WALL
1" N. P.T. OR 1 " C.W.T. SUPPLY
TO FL USH VALVE
(SUGG ESTED)
C/L OF 1/ 2”
DIA . HOLE S
1-1/ 2
SPUD
FINIS HED
FLOOR
13 x 25mm
slots
(1/2 x 1")
217mm
(8-1/ 2)
102mm
(4)
C/L OF
WAS TE
OUT LET
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
DIMENSIONS (Nominal) NOTE: Distance from floor to closet
flange centerline (rough-in) must be 4" (102 mm) with flange
surface flush to 1/16" (1.6mm) max. beyond finished wall.
240m m
(9-1 /2)
419m m
(16- 1/2)
438m m
(17- 1/4)
356m m
(14)
470m m
(18- 1/2)
217m m
(8-1 /2)
102mm
(4)
112 mm
(4- 3/ 8)
752 mm
(29 -5 /8)
C/L OF S EAT POST HOL ES
140m m (5 -1/2 ) CE NTER S
FINI SHED WAL L
C/L O F
WAS TE
OUT LE T
152m m
(6)
102m m
(4)
FINI SHED
FLOO R
13mm
(1/2 )
13 x 25m m
slot s
(1/2 x 1 ")
345m m
(13- 5/8)
646m m
(25- 3/8)
C/L O F 1 /2 ”
DIA . HOL ES
3695.016/3696.016
PRIOLO 16-1/2" HEIGHT
1.28 GPF FLUSHOMETER TOILET
3697.016/3698.016
© 2008 AS America Inc.
NOTES:
PRODUCT 3695.160 AND 3696.160 SHOWN, 3697.160 AND 3698.160
SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST
VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
FLUSHOMETER VALVE NOT INCLUDED WITH FIX TURE AND MUST BE
ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibilit y is
assumed for use of superseded or voided pages.
M68
Revised 11/08