American Standard 3697.016, 3695.016, 3696.016 User Manual

PRIOLO 16-1/2" HEIGHT 1.6 GPF
BARRIER FREE
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES - CHECK LOCAL CODES.
• Floor mount rear outlet ushometer valve toilet
• Vitreous china
• Low-consumption (6.0 Lpf/1.6 gpf)
• EverClean® surface inhibits the growth of stain- and odor-causing bacteria, mold, and mildew on the surface
• 16-1/2" rim height for accessible application
• Condensation channel
• Elongated bowl
• Powerful direct-fed siphon jet action
• Fully glazed 2-1/8" trapway
• 1-1/2" inlet spud
• 2 bolt caps
• 100% factory ush tested
3695.016 Elongated bowl only, top spud ❏ 3697.016 Elongated bowl only, back spud 3696.016 Elongated bowl only, top spud with
slotted rim for bedpan holding (White only)
3698.016 Elongated bowl only, back spud with
slotted rim for bedpan holding (White only)
PRIOLO 16-1/2" HEIGHT
1.6 GPF FLUSHOMETER TOILET
Component Parts:
047007-0070A Inlet spud (furnished with bowl)481310-100 Bolt caps with retainers
(furnished with bowl)
Nominal Dimensions:
752 x 356 x 438mm (29-5/8" x 14" x 17-1/4")
Recommended working pressure–between 25 psi at valve when ushing and 80 psi static
Fixture only, less seat and ush valve
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
• CAN/CSA International B45
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specied:
Color: White Bone Linen Seat: American Standard #5901.100 Heavy duty open
front less cover American Standard #5905.100 Extra heavy duty open front less cover
Alternative Seat: Olsonite #95 open front seat less cover Church #9500C open front seat less cover Flushometer Valve: American Standard Selectronic™ #6065.161.002
DC Power (Top Spud) American Standard Selectronic™ #6065.261.007 DC Power (Back Spud) American Standard Selectronic™ #6067.261.007 AC Power (Back Spud) American Standard Selectronic™ #6068.261.007 Multi AC Power (Back Spud)
© 2008 AS America Inc.
M65
Revised 11/08
BARRIER FREE
730mm
(28-3 /4)
121mm
(4-3/ 4)
240mm
(9-1/ 2)
152mm
(6)
102mm
(4)
419mm
(16-1 /2)
470mm
(18-1 /2)
356mm
(14)
13mm
(1/2)
345mm
(13-5 /8)
646mm
(25-3 /8)
60m m (2- 3/8)
136 mm (5- 3/8)
752 mm
(29 -5/8)
C/L O F SEAT PO ST HOLES 140mm (5-1/2) CENTERS
FINIS HED WALL
1" N. P.T. OR 1 " C.W.T. SUPPLY TO FL USH VALVE (SUGG ESTED)
C/L OF 1/ 2” DIA . HOLE S
1-1/ 2 SPUD
FINIS HED FLOOR
13 x 25mm
slots
(1/2 x 1")
217mm
(8-1/ 2)
102mm
(4)
C/L OF WAS TE OUT LET
DIMENSIONS (Nominal) NOTE: Distance from floor to closet flange centerline (rough-in) must be 4" (102 mm) with flange surface flush to 1/16" (1.6mm) max. beyond finished wall.
DIMENSIONS (Nominal) NOTE: Distance from floor to closet flange centerline (rough-in) must be 4" (102 mm) with flange surface flush to 1/16" (1.6mm) max. beyond finished wall.
240m m
(9-1 /2)
419m m
(16- 1/2)
438m m
(17- 1/4)
356m m
(14)
470m m
(18- 1/2)
217m m
(8-1 /2)
102mm
(4)
112 mm (4- 3/ 8)
752 mm
(29 -5 /8)
C/L OF S EAT POST HOL ES 140m m (5 -1/2 ) CE NTER S
FINI SHED WAL L
C/L O F WAS TE OUT LE T
152m m
(6)
102m m
(4)
FINI SHED FLOO R
13mm
(1/2 )
13 x 25m m
slot s
(1/2 x 1 ")
345m m
(13- 5/8)
646m m
(25- 3/8)
C/L O F 1 /2 ” DIA . HOL ES
3695.016/3696.016
PRIOLO 16-1/2" HEIGHT
1.6 GPF FLUSHOMETER TOILET
3697.016/3698.016
© 2008 AS America Inc.
NOTES:
PRODUCT 3695.160 AND 3696.160 SHOWN, 3697.160 AND 3698.160 SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. FLUSHOMETER VALVE NOT INCLUDED WITH FIX TURE AND MUST BE ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR 12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED. REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibilit y is assumed for use of superseded or voided pages.