American Standard 3357.128, 3358.128, 3355.128, 3356.128 User Manual

AFWALL™ FloWise® ADA RETROFIT
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES - CHECK LOCAL CODES.
When installed so top of seat is 432 to 483mm (17" to 19") from the finished floor.
BARRIER FREE
• Wall-mounted ushometer valve toilet
• Vitreous china
• Meets denition for HET (High Efciency Toilet)
• High Efciency (4.8 Lpf/1.28 gpf)
• EverClean® surface inhibits the growth of stain- and odor-causing bacteria, mold, and mildew on the surface
• Elongated bowl
• Powerful direct-fed siphon jet action
• Fully-glazed 2-1/8" trapway
• 10" x 12" water surface area
• Condensation channel
• 1-1/2" inlet spud
• 100% factory ush tested
3355.128 Elongated bowl only, top spud3356.128 Elongated bowl only, top spud with
slotted rim for bedpan holding (White only)
3357.128 Elongated bowl only, back spud3358.128 Elongated bowl only, back spud with
slotted rim for bedpan holding (White only)
AFWALL™ FloWise® ADA RETROFIT
1.28 GPF FLUSHOMETER TOILET
Afwall ADA 1.28 replaces standard wall-hung 3.5 or 1.6 models and roughs-in at 410mm (16-1/8") rim height to meet ADA with no need to modify the existing carrier or through wall supply (providing centerline of current outlet is 133mm [5-1/4"] above
nished oor).
Component Parts:
047007-0070A Inlet spud (furnished with bowl)736046-100 Flushometer valve rough-in adapter
kit (furnished with bowl)
Nominal Dimensions:
660 x 356 x 419mm (26" x 14" x 16-1/2")
For Top spud bowls, American Standard kit #736046-100 Flushometer Valve Conversion Kit containing a 25mm (1") chrome-plated street ell, a vacuum breaker, and a 330mm (13") tail piece included to meet minimum 152mm (6") code between bowl and vacuum breaker.
Recommended working pressure–between 25 psi at valve when ushing and 80 psi static
Fixture only, less seat, carrier, bolt caps, and ushometer valve
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
• CAN/CSA International B45
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specied:
Color: White Bone Silver Linen Black Seat: American Standard #5901.100 Heavy duty open
front less cover American Standard #5905.100 Extra heavy duty open front less cover
Flushometer Valve:American Standard Selectronic™ #6065.121.002
DC Power (Top Spud) American Standard Selectronic™ #6065.222.007 DC Power (Concealed Back Spud) American Standard Selectronic™ #6067.222.007 AC Power (Concealed Back Spud) American Standard Selectronic™ #6068.222.007 Multi AC Power (Concealed Back Spud)
© 2008 AS America Inc.
M71
Revised 11/08
3355.128/3356.128
FIN ISH ED WA LL
470 mm
(18 -1/ 2)
C/L OF SE AT POS T HOL ES 140 mm (5- 1/2) C ENTER
660 mm
(26 )
73m m (2- 7/8 )
133mm
(5-1/4)
191mm
(7-1/2)
292mm
(11-1/2)
(4) 22mm
(7/8)
HOLES
356 mm
(14 )
C/L OF OUTLET
121 mm
(4- 3/4 )
FINISHED
FLOOR
32mm (1-1/4)
419mm (16-1/2)
1" N.P.T. OR C.W.T. SUPPLY
AS REQUIRED TO FLUSH VALVE
368mm (14-1/2)
19mm
(3/4)
133mm
(5-1/4)
83mm (3-1/4)
62mm (2-3/8)
1-1/2 SPUD
C/L
229mm
(9)
FINISHED WALL
470mm (18-1/2)
C/L OF SEAT PO ST HOLES 140mm(5 -1/2) C ENTERS
660mm
(26)
133mm
(5-1/4)
191mm
(7-1/2)
(4) 22mm (7/8)
DIA. HOLES
356mm
(14)
C/L OF OUTLET
FINISHED
FLOOR
32mm (1-1/4)
419mm (16-1/2)
368mm (14-1/2)
(3/4)
19mm
133mm
(5-1/4)
83mm
(3-1/4)
C/L
229mm
(9)
127mm (5)
76mm(3) DIA. HOLE IN WALL FOR 1-1/2 SPUD
62mm
(2-3/8)
320mm
(12-9/16)
367mm
(14-7/16)
BARRIER FREE
AFWALL™ FloWise® ADA RETROFIT
1.28 GPF FLUSHOMETER TOILET
© 2008 AS America Inc.
3357.128/3358.128
NOTES:
Toilet designed to meet ADA accessibility standards when top of seat height set at 432 to 483mm (17" to 19") from nished oor.
PRODUCT 33 55.128 AND 3357.128 SHOWN, 3356.128 AND 3358.128 SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.
REQUIRES AMERICAN STANDARD KIT 736046 -100 TO UPGRADE EXISTING
*
INSTALLATION OF FLUSHOMETER VALVE AND COMPONENTS. WASTE OUTLET SE AL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING NOT RECOMMENDED). SUGGESTED 1/16 CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. FLUSHOMETER VALVE NOT INCLUDED WITH FIX TURE AND MUST BE ORDERED SEPARATELY. CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
M72
Revised 11/08
Loading...