American Standard 3351.101, 3352.101, 3353.101, 3354.101, 2257.101 Installation Manual

...
INSTALLATION INSTRUCTIONS
AFWALL® MILLENNIUM™ FLUSHOMETER WALL-MOUNTED TOILETS
Models 3351.101, 3352.101, 3353.101, 3354.101, 2257.101, 2257.101.NAF, 2633.101, 2634.101
Meets the American Disabilities Act Guidelines and ANSI A117.1 Requirements for the Physically Challenged
Thank you for selecting American Standard – the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR HANDLING
!
TO AVOID BREAKAGE AND POSSIBLE INJURY!
NOTE: For proper operation product requires a minimum of 30 psi working line pressure
RECOMMENDED TOOLS AND MATERIALS
Closet Carrier Support Putty Knife
Pictures may not exactly define contour of china
1
FINISHED WALL
Sealant Tape Measure
Carpenters Level Flush Valve
73mm
2
FIXTURE MOUNTING
(2-7/8")
41mm (1-5/8")
660mm
(26")
Fixture studs should project 58mm (2-1/4") from face of finished wall.
FINISHED WALL
58mm (2-1/4")
(4) STUDS
470mm
(18-1/2")
333mm
(13-1/8")
FINISHED
FLOOR
381mm
(15")
356mm
(14")
(4) Ø 22mm
(7/8") HOLES
229mm
(9")
NOTE: If carrier bolt does not extend or is flush with china, use retrofit caps 7381285-200.0070A (sold separately).
191mm (7-1/2")
133mm (5-1/4")
STANDARD BOLT CAP
WALL
STANDARD BOLT CAP
CHINA / TOILET
SAVE FOR FUTURE USE
SIDE VIEW
FRONT VIEW
Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2014
RETROFIT BOLT CAP
WALL
RETROFIT BOLT CAP
CHINA / TOILET
7301962-100 Rev. E
3
Place back-up nuts on both bottom bolts, and the top left-hand bolt only.
Adjust the two lower back-up nuts so that front
4
Using a level, adjust the top left back-up nut so that it is in the same vertical plane as the lower left back-up nut.
face of nuts and washers are positioned to allow a minimum 1/16" (2mm) gap between fixture and wall surface.
Adjust waste horn to project 7mm (5/16") from finished wall.
FINISHED WALL
FINISHED WALL
2mm (1/16") (IRREGULAR WALL SURFACE)
CLOSET CARRIER
SYSTEM
(3) NUTS
7mm (5/16" )
5
NOTE: Bearing nuts and washers must be set to take full loading from the fixture allowing 1/16" (2mm) clearance between fixture and wall.
Follow support manufacturer's recommended setting of closet outlet connection.
Place felt or neoprene gasket (wax ring not recommended) on closet outlet.
When the fixture is installed, closet outlet gasket must be compressed sufficiently to assure a gas and watertight seal.
The following steps require a helper:
LEVEL
WASTE HORN
Install bowl on support using cap nuts and fiber washers with the back-up nuts and washers.
DO NOT APPLY TOP RIGHT FIBER WASHER AND CAP NUT UNTIL OTHER CAP NUTS HAVE BEEN FIRMLY TIGHTENED USING A WRENCH.
Install top right cap nut with fiber washer and run up hand tight. Wrench tighten approximately 1/4 turn.
Apply sealant to gap between bowl and finished wall. Remove excess sealant.
In the United States:
American Standard Brands
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
American Standard B&K Mexico
Ecatepec 55540 Edo. Mexico
www.americanstandard.com.mx
In Mexico:
S. de R.L. de C.V. Via Morelos #330
Col. Santa Clara
Toll Free: 01-800-839-1200
- 2 -
7301962-100 Rev. E
Loading...
+ 4 hidden pages