American Standard 2981, 2980 User Manual

Installation
Instructions
THE
“”
COLLECTION
by
DECK-MOUNT BATH FILLER
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
2980 2981
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Required Tools
Flat Blade Screwdriver
*Wrench
Adjustable Wrench
Channel Locks
SPOUT ASSEMBLY
1
Turn off hot and cold water supplies before beginning.
Insert SPOUT SHANK (1) through center hole of MOUNTING LEDGE. Make sure that the RUBBER RING (2) is properly seated in RECESS at base of SPOUT (3).
Assemble RUBBER WASHER (4) and BRASS WASHER (5) onto SHANK (1). From underside of ledge secure SPOUT (3) into position with LOCKNUT (6).
*Hex key
*Supplied with Fitting
ROUGHING-IN DIMENSIONS
4-1/4"
MOUNTING
SURFACE
8-5/8"
2-7/8"
3/4-14 MALE N.P.T. INLETS
2
2-1/2D.
1-1/8 D.
1-1/16 D.
PREPARE TUBE AND TEE ASSEMBLY
Prepare TUBE and TEE ASSEMBLY (1) to fit center to center VALVE (2) location (between 6-1/2" and 12"). If necessary, cut and/or bend TUBING carefully. Make sure tube bend is close to the TEE (1) so that it will not effect the compression joint at the VALVE CONNECTION.
Remove COUPLING NUT (3) and FERRULE (4) from each VALVE (2) and slide onto TUBING (5).
3-1/2"
(H)
Certified to comply with ANSI A112.18.1M
ADJ. 6-1/2 TO 12
2-1/2D.
1-1/4
MAX.
4
3
3
(C)
12 MAX
M968212
2-1/16
D.
1-1/2 MAX.
1-3/16 D.
7-1/4
RECESS
4
6
1
5
3
3
4
1
2
MOUNTING LEDGE.
2-1/2D.
ADJ. 6-1/2 TO 12
2-1/2D.
MOUNTING
SURFACE
5
2
NOTE
VALVE inlet is 3/4-inch NPT male.
VALVE ASSEMBLY
3
Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks. Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4)
into mounting holes from underside of ledge. Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is
properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and attach to SPOUT SHANK (6) and tighten.
Thread of VALVE BODY (4) should extend at least 5/16 inch above MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).
Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and thread onto valves until snug against internal stop.
Tighten LOCKNUT (1) to secure VALVE (4) position.
Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4) and tighten COUPLING NUT (13) firmly.
Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of right VALVE using appropriate connector.
9
11
2 1
MOUNTING SURFACE
INSTALL HANDLES
4
5/16'' MIN.
10
4
9
10
HOT
MOUNTING
SURFACE
4
12
13
3
5
8
11
13
9
10
7
6
12
4
COLD
6
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the ADAPTER (1) without spline is facing up. See figure "A".
Thread HANDLE BASE (3) onto DECK ADAPTER (7)
Push HANDLE (4) onto ADAPTER (1).
Find correct position of HANDLE (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4).
Secure HANDLE (4) with HANDLE SCREW (5).
Push INDEX CAP (6) in hole of HANDLE (4).
SERVICE
5
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position. Pull out INDEX CAP (1) and remove HANDLE SCREW (2). Pull off HANDLE (3), and unscrew ESCUTCHEON (4). Pull off STEM ADAPTER (7). Remove SPRING CLIP (6). Lift STOP WASHER (5), turn 90° and replace. Replace SPRING CLIP (6) and STEM ADAPTER (7). Reinstall ESCUTCHEON (4) and HANDLE ASSEMBLY (1,2 & 3).
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90°.