American Standard 2903, 2806, 2935, 2933, 2664 User Manual

...
Page 1
INSTALLATION AND
OPERATION MANUAL
MODEL 2664
MODEL 2709
MODEL 2711
MODEL 2742
MODEL 2748
MODEL 2806
MODEL 2903
MODEL 2908
MODEL 2932
MODEL 2933
MODEL 2934
MODEL 2935
MODEL 2938
MODEL 2939
MODEL 2940
MODEL 2941
MODEL 2942
MODEL 2943
MODEL 2944
MODEL 2945
MODEL 3572
MODEL 3573
MODEL 3574
MODEL 3575
MODEL 3581
MODEL 3582
MODEL 3583
MODEL 3584
MODEL 6060
MODEL 7236
MODEL 3571
BATHTUBS, WHIRLPOOLS, AIR BATHS
AND COMBINATION TUBS WITH
OPTIONAL CHROMATHERAPY
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool and air bath versions are completely assembled with pump/blower and system piping. All you need to finish the installation are your selected fittings and electrical connections.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.
For questions or service issues, please call Technical Support 1-(800)-442-1902. Please do not contact or return product to the store.
© AS America, Inc. 2010 All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.
1
754532-100 Rev. A
Page 2
TABLE OF CONTENTS:
Cover
................................................................................................Page 1
Table of Contents
Safety Instructions Notice.................................................................Page 3
Installation, Framing and Post Installation
Clean-Up Instructions.......................................................................Page 4
Roughing-in References for Recess Type Installations.....................Page 5
Roughing-in References for Pier Type Installations...........................Page 6
Under Deck Mounting Instructions....................................................Page 6
Roughing-in References for All Model Series...................................Pages 7 - 26
..............................................................................Page 2
Electrical Installation Instructions
Whirlpool Heater Operation
......
.....................................................Pages 27 - 32
..........................................................Page 32
Remote Air Blower Location Option..................................................Pages 33 - 34
Operation: Single Speed Whirlpool...................................................Page 35
Operation: EcoSilent Whirlpool with Lights.......................................Page 36
Operation: Air Bath............................................................................Page 37
Operation: Air Bath with Lights..........................................................Pages 38 - 39
Operation: Combination Tub with Lights...........................................Pages 40 - 41
Cleaning and Maintenence...............................................................Page 42
Warranty
754532-100 Rev. A
......................................
.....................................................Page 43
2
Page 3
IMPORTANT SAFETY
INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS!
!
WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. Never drop or
insert any object into any opening. Do not operate this unit without the guard over the suction fitting.
!
WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water.
!
WARNING:
history should consult a physician before using this product.
!
WARNING:
cause overflow and slippery conditions. Exercise caution when entering and exiting.
!
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not recommended. Avoid
alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.
!
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a licensed electrician before using.
Risk of hyperthermia and possible drowning.
Risk of personal injury.
Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can
People using medications and/or having adverse medical
SAVE THESE INSTRUCTIONS
3
754532-100 Rev. A
Page 4
Installation and Framing Instructions
Each bath arrives ready for installation, completely equipped with the pump/blower electronics and plumbing necessary for operation. However, a drain/overflow kit is required for each bath and it is not included.
The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square.
!
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the bath by the plumbing at any time; handle by the shell only.
!
All bath units are factory tested for proper operation and watertight connections prior to shipping. Prior to installation, the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling.
The sumps of these baths are supported by feet and no additional sump
!
support is required. Once the bath is in place, the feet should be shimmed and secured accordingly so that the rim of the bath contacts the stringer or pier but supports no weight.
Provisions must be made in all installations for an access opening for servicing the
!
bath pump/blower. Unless an access opening of at least 12" x 24" (305mm x 610mm) is provided, warranty service will not be performed. It is strongly recommended that an additional opening be provided for access to drain components.
!
Each bath has a nominal length (L), width (W), and Height (H) along with a rim height. Unless otherwise noted in the following rough-in references, assume that the nominal tolerances are as much as +/-1/4 inch (6mm). Therefore, it is strongly recommended that the installer build the surrounding structure after receiving the actual bath. Structural measurements should be verified against the actual bath received to ensure proper fit.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent.
Stubborn dirt or stains may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
754532-100 Rev. A
4
Page 5
ROUGH-IN REFERENCES FOR RECESS TYPE INSTALLATIONS
C
NOTE:
FRONT EDGE OF BATH MUST BE SUPPORTED BY STUD WALL OR AMERICAN STANDARD APRON KIT
UNLESS AN ACCESS OPENING OF AT LEAST 12" x 24" (305 x 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
TYPICAL TILE FLANGE INSTALLATION
WOOD
STUDS
WATERPROOF DRYWALL OR CEMENT BOARD
STUD
TILE
ROOFING NAIL
SEALANT
D
W
E
LEVELING STRINGERS
ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED FOR BATH TUBS
(610 mm)
24"
12"
(305 mm)
TYPICAL TILE BEAD INSTALLATION
TILE
WALLBOARD
TUB
1" x 3" (25 x 76mm) WOOD STRINGER FULL LENGTH
STEEL
STUDS
STEEL
STUD
WATERPROOF DRYWALL OR CEMENT BOARD
TILE
SEALANT
TUB
1" x 3" (25 x 76mm) WOOD
STRINGER FULL LENGTH
SECURE THE BATH TO THE STUDS AS SHOWN
FOR WOOD OR STEEL STUD CONSTRUCTION.
WASHER
4" (102mm) DRYWALL SCREW
SEALANT
TILE
BEAD
BATH
STRIP
ADHESIVE
LEVELING STRINGER
1" x 4" (25mm x 102mm) not for support
NOTE: Tile bead kit not included and must be purchased separately.
5
754532-100 Rev. A
Page 6
ROUGH-IN REFERENCES FOR PIER TYPE INSTALLATIONS
AS DESIRED
F
CUTOUT
G
C
AS DESIRED
MOUNTING SURFACE
WATERPROOF SEALANT
CUTOUT
24"
(610 mm)
(305 mm)
12"
BATH
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)
IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
ACCESS PANEL MUST BE LOCATED ON THE SAME SIDE AS THE MOTOR.
ALLOW OPEN FRAMING ON PUMP/MOTOR END FOR SERVICE.
ACCESS PANELS NOT REQUIRED FOR BATH TUBS
UNDER DECK MOUNTING INSTRUCTIONS
Please note that care must be taken to protect the surface of the tub during all aspects of the installation. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
1. Install the tub per the installation instructions provided with the unit.
2. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.
3. Cut bath deck to your specifications.
4. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.
5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.
6. Replace the bath deck and secure it into place.
7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.
8. Remove excess sealant per the manufacturer's instructions.
Finished bath deck surface material must be
self-supporting and secured per local codes
754532-100 Rev. A
Waterproof
Bathtub
Sealant
Bath deck support material
Tub support structure per installation instructions provided with the tub
6
Page 7
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR WHIRLPOOLS AND BATH TUBS
Description
2664
Scala
Corner
2709
Ellisse Oval
2711
Ellisse
6' x 48"
2742
Town Square
6' x 42"
2748
Town Square
5' x 42"
2806
Heritage Oval
6' x 36"
2903
Savona Oval
5' x 42"
2908
Reminiscence
Oval
6060
Cadenza
Corner
7236
Virtuoso
6' x 36"
SIDE VIEW
L 83-1/2" (2121mm) W 63-3/4" (1619mm) H 19-3/4" (502mm)
L 69-1/4" (1759mm) W 38-1/2" (978mm) H 19-3/4" (502mm)
6'
L 72" (1829mm) W 48" (1219mm) H 21-1/2" (546mm)
L 71-1/2" (1816mm) W 41-3/4" (1060mm) H 22" (559mm)
L 59-1/2" (1511mm) W 41-5/8" (1057mm) H 23" (584mm)
L 72" (1829mm) W 35-3/4" (908mm) H 21-1/2" (546mm)
L 60" (1524mm) W 42-1/4" (1073mm) H 21-1/4" (540mm)
L 66" (1676mm) W 36" (914mm) H 24-1/4" (616mm)
L 76-3/4" (1949mm) W 65-3/8" (1661mm) H 21-1/2" (546mm)
L 72" (1829mm) W 36" (914mm) H 21-1/4" (540mm)
Dimensions
L-W-H
Drain /
Overflow
A 16" (406mm) B 13-1/4" (337mm)
A 15" (381mm) B 9-7/8" (251mm)
A 16-5/8" (422mm) B 12" (305mm)
A 16-1/4" (413mm) B 13-1/4" (337mm)
A 14-1/2" (368mm) B 14-1/2" (368mm)
A 17" (432mm) B 11" (279mm)
A 17" (432mm) B 9-1/2" (241mm)
A 17" (432mm) B 13" (330mm)
A 17" (432mm) B 13-3/4" (349mm)
A 17-3/4" (451mm) B 11" (279mm)
Height to Underside of Deck: C
C 18-1/4" (464mm)
C 18-1/4" (464mm)
C 19-1/2" (495mm)
C 20" (508mm)
C 21" (533mm)
C 19-1/2" (495mm)
C 19-1/4" (489mm)
C 18-1/4" (464mm)
C 19-1/2" (495mm)
C 19-1/4" (489mm)
H
Cut Out
Pier
G x F
Template Provided
Template Provided
70-1/2" (1791mm) x 46-1/2" (1181mm)
70" (1778mm) x 40-1/4" (1022mm)
58" (1473mm) x 40-1/8" (1019mm)
Template Provided
Template Provided
Template Provided
Template Provided 751680-100
70-1/2" (1791mm) x 34-1/2" (876mm)
END VIEW
Rough-In
Recess
E x D
N/A
As Desired
72-3/16" (1833mm) x 46-1/2" (1181mm)
71-11/16" (1821mm) x 40-1/4" (1022mm)
59-11/16" (1517mm) x 40-1/8" (1019mm)
As Desired
As Desired
As Desired
N/A
72-3/16" (1833mm) x 34-1/2" (876mm)
Tub Edge to
Centerline
Overflow: J
6-3/8" (162mm)
3" (76mm)
4" (102mm)
4" (102mm)
5-1/4" (133mm)
5-1/2" (140mm)
3" (76mm)
6" (152mm)
5-5/8" (130mm)
4" (102mm)
C
Weight with
Water / Floor
Loading
781 lb. (351 kg)/ 37 lb./sq.ft. (182 k
640 lb. (291 kg)/ 35 lb./sq.ft. (171 kg/sq.m)
950 lb. (431 kg)/ 40 lb./sq.ft. (196 kg/sq.m)
690 lb. (313 kg)/ 33 lb./sq.ft. (161 kg/sq.m)
611 lb. (277 kg)/ 40 lb./sq.ft. (196 kg/sq.m)
744 lb. (338 kg)/ 41 lb./sq.ft. (200 kg/sq.m)
640 lb. (291 kg)/ 35 lb./sq.ft. (171 kg/sq.m)
659 lb. (299 kg)/ 40 lb./sq.ft. (191 kg/sq.m)
824 lb. (374 kg)/ 25 lb./sq.ft. (117 kg/sq.m)
751 lb. (338 kg)/ 42 lb./sq.ft. (204 kg/sq.m)
g/sq.m)
A
Product
Weight
94 lb. (43 kg.)
107 lb. (49 kg.)
133 lb. (60 kg.)
115 lb. (52 kg.)
110 lb. (50 kg.)
135 lb. (61 kg.)
107 lb. (49 kg.)
95 lb. (43 kg.)
108 lb. (49 kg.)
101 lb. (45 kg.)
DRAIN / OVERFLOW
B
Gallon to Overflow
80 gal. (303 l.)
64 gal. (242 l.)
95 gal. (359 l.)
69 gal. (261 l.)
60 gal. (227 l.)
73 gal. (276 l.)
64 gal. (242 l.)
68 gal. (257 l.)
86 gal. (352 l.)
78 gal. (296 l.)
Whirlpool Operating
Volume
58 gal. (220 l.)
53 gal. (200 l.)
74 gal. (280 l.)
60 gal. (227 l.)
55 gal. (208 l.)
44 gal. (166 l.)
53 gal. (200 l.)
55 gal. (208 l.)
71 gal. (269 l.)
69 gal. (262 l.)
TABLE 1
7
754532-100 Rev. A
Page 8
ROUGH-IN REFERENCES
MODEL SERIES 2664
60"
64- 1/ 4"
(1632mm)
42- 1/ 2"
(108 0m m)
63- 1/ 2"
63- 3/ 4"
(1600mm)
(1619mm)
21-3/ 4"
(55 2m m)
CUTOUT D IM EN SI ON
C
(1524mm)
59- 1/ 4" ( 150 5m m)
REC OM ME ND ED FITT IN G LOCATI ON
2-1 /2 " x 11" (64 x 2 79 mm)
8-1 /2 "
(216mm)
3/4 "( 19m m)
OF DR AI N OU TLET
L
28- 1/ 2" ( 72 4mm)
10" x 10"
(25 4m m x 25 4mm)
DRA IN O UT LE T
CUTOUT
16"
(40 6m m)
(104 1m m)
41"
53- 3/ 8"
(1356mm)
1" (2 5m m) INT EGRAL TILE FLA NG E (2 ) SIDES
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
30- 1/ 2"
(77 5m m)
38- 1/ 2"
(97 8m m)
19-1/ 4"
(489 mm)
(76mm )
MODEL SERIES 2709
69- 1/ 4"
9-7 /16" (24 0m m)
12" (305mm) x 9" (229mm) CUTOUT IN FLOOR FOR DRAIN
3"
OF DRAIN
C
L
OUTLET
(1759mm)
OUTLINE OF CUTOUT
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
754532-100 Rev. A
8
Page 9
(305mm)
48"
(1219mm)
12"
ROUGH-IN REFERENCES
MODEL SERIES 2711
72"
36- 1/ 2"
(92 7m m)
(1829mm)
OUT LI NE O F CUTOUT 70- 1/ 2" X 4 6-1/2" (1791 X 1181m m)
9" x 14" (22 9 x 35 6m m) FLO OR CUTOUT
4" (102 mm )
C/L O F DRA IN
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
REC OM ME ND ED
FIT TI NG
LOCATION
2-1 /2 " X 11"
13"
(330m m)
18"
(457m m)
36"
(914mm)
INTEGR AL
FITTING
DECK
6"
(152mm)
GRAB BAR
FITTING AREA
MODEL SERIES 2908
OVER FLOW
C/L O F DRA IN OUT LE T
OPTIONAL
DECK FITTING
(1676mm)
9" X 12" (22 9 x 30 5m m) FLO OR CUTOUT
2-1 /2 " RE F. (64 mm )
OUT LI NE O F
CUTOUT
AREA
66"
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
9
754532-100 Rev. A
Page 10
35-3/4"
(908mm)
11"
(279mm)
18"
(457mm)
INTEG RAL
FITTI NG
DECK
5-1/2"
(140mm)
ROUGH-IN REFERENCES
MODEL SERIES 2806
72"
(1829mm)
9" x 13" (229 x 330mm) FLOOR CUTOUT
C/L O F DR AI N
OVE RF LO W
OUT LI NE
OF CU TO UT
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
4-1/4"
(1073mm)
21-1/8"
(537mm)
3"
(76mm)
C
OF DRAIN
L
OUTLET
MODEL SERIES 2903
60"
9-1/2"
(241mm)
CUTOUT IN FLOOR FOR DRAIN
(1524mm)
12" (305mm) X 9"(229mm)
OUTLINE OF CUTOUT - USE TEMPLATE
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
754532-100 Rev. A
10
Page 11
ROUGH-IN REFERENCES
MODEL SERIES 2742
(102mm)
13-1/4"
(337mm)
41-3/4"
(1060mm)
4"
3/4"
(19mm)
35-3/4"
(908mm)
C/L OF DRAIN OUTLET
26-3/4"
(679mm)
71-1/2"
(1816mm)
FLOOR CUTOUT 5" X 15" (127 X 381mm)
INTEGRAL FITTING DECK 3" x 14" (76 x 356mm)
OUTLINE OF CUTOUT
70" X 40-1/4"
(1778 X 1022mm)
3" (76mm)
EDGE
OF FLOOR
CUTOUT
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
(368mm)
41-5/8"
(1057mm)
14-1/2"
MODEL SERIES 2748
59-1/2"
(1511mm)
29-7/8"
(759mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
INTEGRAL FITTING DECK 3" X 14" (76 X 356mm)
FLOOR CUTOUT 5" X 12" (127 X 305mm)
3"
(76mm)
3/4"
(19mm)
OUTLINE OF CUTOUT 58-1/4" X 40-1/4" (1480 X 1022mm)
5-1/4"
(133mm)
C/L OF DRAIN OUTLET
EDGE OF FLOOR CUTOUT
11
754532-100 Rev. A
Page 12
ROUGH-IN REFERENCES
MODEL SERIES 6060
65-3/8"
(1661mm)
13-5/8"
(346mm)
(143mm)
38-3/8"
(975mm)
C/L
SEAT AREA
7" x 15" CUTOUT
(178mm x 381mm)
5-5/8"
OUTLINE OF
CUTOUT
C/L OF
DRAIN
10"
(254mm)
(1384mm)
4-1/2"
(114mm)
76-3/4" REF.
(1949mm)
54-1/2"
(1605mm)
63-3/16"
RECOMMENDED FITTING LOCATION 2-1/2" x 15" (64 x 381mm)
USE CUTOUT TEMPLATE SUPPLIED WITH PACKAGED PRODUCT.
PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS
NOTE: APRON ASSEMBLY WILL PROVIDE REQUIRED ACCESS FOR SERVICING
OUTLINE OF CUTOUT
70-1/2" x 34-1/2"
(1791mm X 876mm)
36"
(914mm)
11"
(279mm)
C/L OF DRAIN
36"
(914mm)
MODEL SERIES 7236
(1829mm)
7 x 14 CUTOUT (178 x 356mm)
4" (102mm)
RECOMMENDED FITTING LOCATION 2-1/2" x 11" (64 x 279mm)
72"
18-1/2"
(470mm)
3/4" (19mm) TYP.
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
754532-100 Rev. A
12
Page 13
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR STUDIO 5' X 32" WHIRLPOOLS AND BATH TUBS
Description
2932
Studio
5' x 32"
2932
Studio
5' x 32"
2932
Studio
5' x 32"
2933
Studio
5' x 32"
w/Tile Flange
SIDE VIEW
Deck
Trim
Option
L 59-1/2" (1511mm)
Zero
W 31-1/2" (800mm)
(5/8")
H 22-1/2" (572mm)
L 59-3/4" (1518mm)
2"
W 31-3/4" (806mm) H 22-1/2" (572mm)
L 60" (1524mm)
4"
W 32" (813mm) H 22-1/2" (572mm)
L 60" (1524mm)
N/A
W 31-7/8" (810mm) H 22-1/2" (572mm)
Dimensions
L-W-H
Drain /
Overflow
A 17-3/4" (451mm) B 10-3/4" (273mm)
A 17-3/4" (451mm) B 10-7/8" (276mm)
A 17-3/4" (451mm) B 11" (279mm)
A 17-3/4" (451mm) B 11" (279mm)
H
Height to Underside of Deck: C
C 21-7/8" (556mm)
C 20-1/2" (521mm)
18-1/2" (470mm)
C 20-1/2" (521mm)
END VIEW
Cut Out
Pier
G x F
58" (1473mm) x 30" (762mm)
58-1/4" (1480mm) x 30-1/4" (768mm)
58-1/2" (1486mm) x 30-1/2" (775mm)
N/A
Rough-In
Recess
E x D
59-11/16" (1516mm) x 30" (762mm)
59-15/16" (1522mm) x 30-1/4" (768mm)
60-3/16" (1529mm) x 30-1/2" (775mm)
60-3/16" (1529mm) x 30-3/8" (772mm)
C
Tub Edge to
Centerline
Overflow: J
A
B
Weight with
Water / Floor
Loading
581 lb. (264 kg)/ 44 lb./sq.ft. (213 kg/sq.m)
581 lb. (264 kg)/ 44 lb./sq.ft. (213 kg/sq.m)
581 lb. (264 kg)/ 44 lb./sq.ft. (213 kg/sq.m)
581 lb. (264 kg)/ 44 lb./sq.ft. (213 kg/sq.m)
DRAIN / OVERFLOW
Product
Weight
90 lb. (198 kg.)
90 lb. (198 kg.)
90 lb. (198 kg.)
90 lb. (198 kg.)
Gallon to Overflow
59 gal. (224 l.)
59 gal. (224 l.)
59 gal. (224 l.)
59 gal. (224 l.)
Whirlpool Operating
Volume
54 gal. (205 l.)
54 gal. (205 l.)
54 gal. (205 l.)
54 gal. (205 l.)
TABLE 2
OVERFLOW
C/L DRAIN
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
FLOOR CUTOUT
ROUGH-IN REFERENCES
MODEL SERIES 2932 & 2933
60" NOMINAL
(1524mm)
OUTLINE OF
CUTOUT
32" NOMINAL
(813mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
13
754532-100 Rev. A
Page 14
SPECIFICATIONS:
L
W
J
SIDE VIEW
H
END VIEW
C
A
GENERAL SPECIFICATIONS FOR STUDIO 5' X 36" WHIRLPOOLS AND BATH TUBS
Description
2934
Studio
5' x 36"
2934
Studio
5' x 36"
2934
Studio
5' x 36"
2935
Studio
5' x 36"
w/Tile Flange
Deck
Trim
Option
Zero (5/8")
2"
4"
N/A
Dimensions
L-W-H
L 59-1/2" (1511mm) W 35-1/2" (902mm) H 22-1/2" (572mm)
L 59-3/4" (1518mm) W 35-3/4" (908mm) H 22-1/2" (572mm)
L 60" (1524mm) W 36" (914mm) H 22-1/2" (572mm)
L 60" (1524mm) W 35-7/8" (911mm) H 22-1/2" (572mm)
Drain /
Overflow
A 17-3/4" (451mm) B 10-3/4" (273mm)
A 17-3/4" (451mm) B 10-7/8" (276mm)
A 17-3/4" (451mm) B 11" (279mm)
A 17-3/4" (451mm) B 11" (279mm)
Height to Underside of Deck: C
C 21-7/8" (556mm)
C 20-1/2" (521mm)
18-1/2" (470mm)
C 20-1/2" (521mm)
Cut Out
Pier
G x F
58" (1473mm) x 34" (864mm)
58-1/4" (1480mm) x 34-1/4" (870mm)
58-1/2" (1486mm) x 34-1/2" (876mm)
N/A
Rough-In
Recess
E x D
59-11/16" (1516mm) x 34" (864mm)
59-15/16" (1522mm) x 34-1/4" (870mm)
60-3/16" (1529mm) x 34-1/2" (876mm)
60-3/16" (1529mm) x 34-3/8" (873mm)
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
686 lb. (311 kg)/ 46 lb./sq.ft. (223 kg/sq.m)
686 lb. (311 kg)/ 46 lb./sq.ft. (223 kg/sq.m)
686 lb. (311 kg)/ 46 lb./sq.ft. (223 kg/sq.m)
686 lb. (311 kg)/ 46 lb./sq.ft. (223 kg/sq.m)
DRAIN / OVERFLOW
B
Product
Gallon to
Weight
Overflow
95 lb. (209 kg.)
95 lb. (209 kg.)
95 lb. (209 kg.)
95 lb. (209 kg.)
71 gal. (269 l.)
71 gal. (269 l.)
71 gal. (269 l.)
71 gal. (269 l.)
Whirlpool Operating
Volume
64 gal. (243 l.)
64 gal. (243 l.)
64 gal. (243 l.)
64 gal. (243 l.)
TABLE 3
OVERFLOW
C/L DRAIN
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
FLOOR CUTOUT
ROUGH-IN REFERENCES
MODEL SERIES 2934 & 2935
60" NOMINAL
(1524mm)
OUTLINE OF
CUTOUT
36" NOMINAL
(914mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
754532-100 Rev. A
14
Page 15
SPECIFICATIONS:
L
W
J
SIDE VIEW
H
END VIEW
C
A
B
GENERAL SPECIFICATIONS FOR STUDIO 5-1/2' X 36" WHIRLPOOLS AND BATH TUBS
Description
2938
Studio
5-1/2' x 36"
2938
Studio
5-1/2' x 36"
2938
Studio
5-1/2' x 36"
2939
Studio
5-1/2' x 36"
w/Tile Flange
Deck
Trim
Option
Zero (5/8")
2"
4"
N/A
Dimensions
L-W-H
L 65-1/2" (1664mm) W 35-1/2" (902mm) H 22-1/2" (572mm)
L 65-3/4" (1670mm) W 35-3/4" (908mm) H 22-1/2" (572mm)
L 66" (1676mm) W 36" (914mm) H 22-1/2" (572mm)
L 66" (1676mm) W 35-7/8" (911mm) H 22-1/2" (572mm)
Drain /
Overflow
A 17-3/4" (451mm) B 10-3/4" (273mm)
A 17-3/4" (451mm) B 10-7/8" (276mm)
A 17-3/4" (451mm) B 11" (279mm)
A 17-3/4" (451mm) B 11" (279mm)
Height to
Underside of Deck: C
C 21-7/8" (556mm)
C 20-1/2" (521mm)
18-1/2" (470mm)
C 20-1/2" (521mm)
Cut Out
Pier
G x F
64" (1626mm) x 34" (864mm)
64-1/4" (1632mm) x 34-1/4" (870mm)
64-1/2" (1638mm) x 34-1/2" (876mm)
N/A
Rough-In
Recess
E x D
65-11/16" (1668mm) x 34" (864mm)
65-15/16" (1675mm) x 34-1/4" (870mm)
66-3/16" (1681mm) x 34-1/2" (876mm)
66-3/16" (1681mm) x 34-3/8" (873mm)
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
766 lb. (348 kg)/ 46 lb./sq.ft. (227 kg/sq.m)
766 lb. (348 kg)/ 46 lb./sq.ft. (227 kg/sq.m)
766 lb. (348 kg)/ 46 lb./sq.ft. (227 kg/sq.m)
766 lb. (348 kg)/ 46 lb./sq.ft. (227 kg/sq.m)
DRAIN / OVERFLOW
Product
100 lb. (220 kg.)
100 lb. (220 kg.)
100 lb. (220 kg.)
100 lb. (220 kg.)
Weight
Gallon to Overflow
80 gal. (303 l.)
80 gal. (303 l.)
80 gal. (303 l.)
80 gal. (303 l.)
Whirlpool Operating
Volume
73 gal. (277 l.)
73 gal. (277 l.)
73 gal. (277 l.)
73 gal. (277 l.)
TABLE 4
OVERFLOW
C/L DRAIN
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
FLOOR CUTOUT
ROUGH-IN REFERENCES
MODEL SERIES 2938 & 2939
66" NOMINAL
(1524mm)
OUTLINE OF
CUTOUT
36" NOMINAL
(914mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
15
754532-100 Rev. A
Page 16
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR STUDIO 6' X 36" WHIRLPOOLS AND BATH TUBS
Description
2940
Studio
6' x 36"
2940
Studio
6' x 36"
2940
Studio
6' x 36"
2941
Studio
6' x 36"
w/Tile Flange
SIDE VIEW
Deck
Trim
Option
L 71-1/2" (1816mm)
Zero
W 35-1/2" (902mm)
(5/8")
H 22-1/2" (572mm)
L 71-3/4" (1822mm)
2"
W 35-3/4" (908mm) H 22-1/2" (572mm)
L 72" (1829mm)
4"
W 36" (914mm) H 22-1/2" (572mm)
L 72" (1829mm)
N/A
W 35-7/8" (911mm) H 22-1/2" (572mm)
Dimensions
L-W-H
Drain /
Overflow
A 17-3/4" (451mm) B 10-3/4" (273mm)
A 17-3/4" (451mm) B 10-7/8" (276mm)
A 17-3/4" (451mm) B 11" (279mm)
A 17-3/4" (451mm) B 11" (279mm)
H
Height to
Underside of Deck: C
C 21-7/8" (556mm)
C 20-1/2" (521mm)
18-1/2" (470mm)
C 20-1/2" (521mm)
END VIEW
Cut Out
Pier
G x F
70" (1778mm) x 34" (864mm)
70-1/4" (1784mm) x 34-1/4" (870mm)
70-1/2" (1791mm) x 34-1/2" (876mm)
N/A
Rough-In
Recess
E x D
71-11/16" (1821mm) x 34" (864mm)
71-15/16" (1827mm) x 34-1/4" (870mm)
72-3/16" (1833mm) x 34-1/2" (876mm)
72-3/16" (1833mm) x 34-3/8" (873mm)
C
Tub Edge to
Centerline
Overflow: J
A
B
Weight with
Water / Floor
Loading
846 lb. (384 kg)/ 47 lb./sq.ft. (230 kg/sq.m)
846 lb. (384 kg)/ 47 lb./sq.ft. (230 kg/sq.m)
846 lb. (384 kg)/ 47 lb./sq.ft. (230 kg/sq.m)
846 lb. (384 kg)/ 47 lb./sq.ft. (230 kg/sq.m)
DRAIN / OVERFLOW
Product
105 lb. (231 kg.)
105 lb. (231 kg.)
105 lb. (231 kg.)
105 lb. (231 kg.)
Weight
Gallon to Overflow
89 gal. (337 l.)
89 gal. (337 l.)
89 gal. (337 l.)
89 gal. (337 l.)
Whirlpool Operating
Volume
81 gal. (307 l.)
81 gal. (307 l.)
81 gal. (307 l.)
81 gal. (307 l.)
TABLE 5
OVERFLOW
C/L DRAIN
9" x 15"
(229 x 305mm)
DRAIN ASS’Y
FLOOR CUTOUT
ROUGH-IN REFERENCES
MODEL SERIES 2940 & 2941
72" NOMINAL
(1524mm)
OUTLINE OF
CUTOUT
36" NOMINAL
(813mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
754532-100 Rev. A
16
Page 17
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR STUDIO 6' X 42" WHIRLPOOLS AND BATH TUBS
Description
2942
Studio
6' x 42"
2942
Studio
6' x 42"
2942
Studio
6' x 42"
2943
Studio
6' x 42"
w/Tile Flange
SIDE VIEW
Deck
Trim
Option
L 71-1/2" (1816mm)
Zero
W 41-1/2" (1054mm)
(5/8")
H 22-1/2" (572mm)
L 71-3/4" (1822mm)
2"
W 41-3/4" (1060mm) H 22-1/2" (572mm)
L 72" (1829mm)
4"
W 42" (1067mm) H 22-1/2" (572mm)
L 72" (1829mm)
N/A
W 41-7/8" (1063mm) H 22-1/2" (572mm)
Dimensions
L-W-H
Drain /
Overflow
A 17-3/4" (451mm) B 10-3/4" (273mm)
A 17-3/4" (451mm) B 10-7/8" (276mm)
A 17-3/4" (451mm) B 11" (279mm)
A 17-3/4" (451mm) B 11" (279mm)
H
Height to Underside of Deck: C
C 21-7/8" (556mm)
C 20-1/2" (521mm)
18-1/2" (470mm)
C 20-1/2" (521mm)
END VIEW
Cut Out
Pier G x F
70" (1778mm) x 40" (1016mm)
70-1/4" (1784mm) x 40-1/4" (1022mm)
70-1/2" (1791mm) x 40-1/2" (1029mm)
N/A
Rough-In
Recess
E x D
71-11/16" (1821mm) x 40" (1016mm)
71-15/16" (1827mm) x 40-1/4" (1022mm)
72-3/16" (1833mm) x 40-1/2" (1029mm)
72-3/16" (1833mm) x 40-3/8" (1026mm)
C
Tub Edge to
Centerline
Overflow: J
A
B
Weight with
Water / Floor
Loading
943 lb. (428 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
943 lb. (428 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
943 lb. (428 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
943 lb. (428 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
DRAIN / OVERFLOW
Product
110 lb. (242 kg.)
110 lb. (242 kg.)
110 lb. (242 kg.)
110 lb. (242 kg.)
Weight
Gallon to Overflow
100 gal. (379 l.)
100 gal. (379 l.)
100 gal. (379 l.)
100 gal. (379 l.)
Whirlpool Operating
Volume
91 gal. (345 l.)
91 gal. (345 l.)
91 gal. (345 l.)
91 gal. (345 l.)
TABLE 6
OUTLINE OF
CUTOUT
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
ROUGH-IN REFERENCES
MODEL SERIES 2942 & 2943
OVERFLOW
C/L DRAIN
72" NOMINAL
(1524mm)
9" x 15" (229 x 305mm) DRAIN ASS’Y FLOOR CUTOUT
36" NOMINAL
(813mm)
17
754532-100 Rev. A
Page 18
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS
Description
2944 Studio Corner
2944 Studio Corner
SIDE VIEW
Deck
Trim
Zero
L 83-15/16" (2132mm)
(5/8")
W 61-3/8" (1559mm) H 21-1/2" (546mm)
2"
L 84-1/4" (2139mm) W 31-13/16" (808mm) H 21-1/2" (546mm)
Dimensions
L-W-H
Drain /
Overflow
A 15" (381mm) B 13-1/2" (343mm)
A 15" (381mm) B 13-5/8" (346mm)
H
END VIEW
Height to Underside of Deck: C
C 20-7/8" (530mm)
C 19-1/2" (495mm)
Cut Out
Pier
G x F
Rough-In
Recess
E x D
N/A
N/A
ROUGH-IN REFERENCES
C
Tub Edge to
Centerline
Overflow: J
A
B
Weight with
Water / Floor
Loading
988 lb. (448 kg)/ 27 lb./sq.ft. (133 kg/sq.m)
988 lb. (448 kg)/ 27 lb./sq.ft. (133 kg/sq.m)
DRAIN / OVERFLOW
Product
130 lb. (59 kg.)
130 lb. (59 kg.)
Weight
Gallon to Overflow
103 gal. (390 l.)
103 gal. (390 l.)
Whirlpool Operating
Volume
65 gal. (246 l.)
65 gal. (246 l.)
TABLE 7
61-3/4" NOMINAL
(1568mm)
OUTLINE
OF CUTOUT
MODEL SERIES 2944
59-3/4" NOMINAL
9" x 18"
(229 x 457mm)
FLOOR CUTOUT
45-5/8"L
(1159mm)
84" NOMINAL
(2134mm)
(1518mm)
27-1/2"
(699mm)
PROVIDE ACCESS TO PUMP SERVING ON ALL INSTALLATIONS
NOTE: PUMP EXTENDS APPROXIMATELY 1-1/4" BEYOND TUB DECK
754532-100 Rev. A
18
Page 19
SPECIFICATIONS:
L
W
J
SIDE VIEW
H
END VIEW
C
A
GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS
Description
2945
Studio
Deck
Trim
N/A N/A N/A57 lb.
Dimensions
L-W-H
L 60" (1524mm) W 32" (813mm) H 22" (559mm)
Drain /
Overflow
A 15-3/4" (400mm) B 10-1/4" (260mm)
Height to Underside of Deck: C
C 22-1/2" (572mm)
Cut Out
Pier G x F
Rough-In
Recess
E x D
60-3/16" (1528mm) x 30-1/2" (774mm)
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
597 lb. (271 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
ROUGH-IN REFERENCES
DRAIN / OVERFLOW
B
Product
Weight
(26 kg.)
Gallon to Overflow
54 gal. (246 l.)
Whirlpool Operating
Volume
TABLE 8
(411mm)
32"
(813mm)
16-3/8"
10-1/4"
(260mm)
MODEL SERIES 2945
60"
(1524mm)
57"
2"(50mm) DRAIN O.D.
(1448mm)
OUTLINE OF SKID RESISTANT SURFACE
4"
(102mm)
1-1/2" (38mm)
1-1/2" (38mm)
4" (102mm)
19
754532-100 Rev. A
Page 20
SPECIFICATIONS:
L
W
J
GENERAL SPECIFICATIONS FOR GREEN TEA WHIRLPOOLS AND BATH TUBS
Description
Green Tea
5' x 36"
Green Tea
5-1/2' x 36"
Green Tea
6' x 36"
Green Tea
5' x 42"
Green Tea
6' x 42"
SIDE VIEW
3571
3572
3573
3574
3575
Dimensions
L-W-H
L 60" (1524mm) W 36" (914mm) H 21" (533mm)
L 66" (1676mm) W 36" (914mm) H 21" (533mm)
L 72" (1829mm) W 36" (914mm) H 21" (533mm)
L 72" (1829mm) W 42" (1067mm) H 21" (533mm)
L 72" (1829mm) W 42" (1067mm) H 21" (533mm)
Drain /
Overflow
A 16" (406mm) B 11-1/2" (349mm)
A 16" (406mm) B 11-1/2" (349mm)
A 16" (406mm) B 11-1/2" (349mm)
A 16" (406mm) B 11-1/2" (349mm)
A 16" (40mm) B 11-1/2" (349mm)
Height to Underside of Deck: C
C 19" (483mm)
C 19" (483mm)
C 19" (483mm)
C 19" (483mm)
C 19" (483mm)
H
58-1/2" (1485mm) x 34-1/2" (876mm)
64-1/2" (1638mm) x 34-1/2" (876mm)
70-1/2" (1791mm) x 34-1/2" (876mm)
58-1/2" (1485mm) x 40-1/2"
(1029mm)
70-1/2" (1791mm) x 40-1/2" (1029mm)
Cut Out
Pier
G x F
END VIEW
Rough-In
Recess
E x D
60-3/16" (1529mm) x 34-1/2" (876mm)
66-3/16" (1681mm) x 34-1/2" (876mm)
72-3/16" (1834mm) x 34-1/2" (876mm)
60-3/16" (1528mm) x 40-1/2" (1029mm)
72-3/16" (1834mm) x 40-1/2" (1029mm)
Tub Edge to
Centerline
Overflow: J
3-1/2" (89mm)
3-3/4" (95mm)
3-1/2" (89mm)
3-1/8" (79mm)
3-1/2" (89mm)
C
Water / Floor
519 lb. (236 kg)/ 35 lb./sq.ft. (171 kg/sq.m)
592 lb. (269 kg)/ 36 lb./sq.ft. (176 kg/sq.m)
665 lb. (302 kg)/ 37 lb./sq.ft. (181 kg/sq.m)
656 lb. (298 kg)/ 38 lb./sq.ft. (186 kg/sq.m)
785 lb. (356 kg)/ 37 lb./sq.ft. (181 kg/sq.m)
Weight with
Loading
A
B
Product
Weight
86 lb. (39 kg.)
100 lb. (45 kg.)
115 lb. (52 kg.)
115 lb. (52 kg.)
127 lb. (57 kg.)
DRAIN / OVERFLOW
Gallon to Overflow
52 gal. (197 l.)
59 gal. (223 l.)
66 gal. (250 l.)
65 gal. (246 l.)
79 gal. (299 l.)
Whirlpool Operating
Volume
38 gal. (144 l.)
44 gal. (166 l.)
49 gal. (185 l.)
47 gal. (178 l.)
58 gal. (219 l.)
TABLE 9
754532-100 Rev. A
20
Page 21
ROUGH-IN REFERENCES
MODEL SERIES 3571
60"
(1524mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
36"
(914mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
9"
(229mm)
CUTOUT IN FLOOR FOR DRAIN
OUTLINE OF CUTOUT 58.5" x 34.5" (1486 x 876mm)
MODEL SERIES 3572
66"
(1676mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
C
L
36"
(914mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
9"
(229mm)
CUTOUT IN FLOOR FOR DRAIN
OUTLINE OF CUTOUT 64.5" x 34.5" (1638 x 876mm)
21
C
L
754532-100 Rev. A
Page 22
ROUGH-IN REFERENCES
MODEL SERIES 3573
72"
(1829mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
36"
(914mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
9"
(229mm)
CUTOUT IN FLOOR FOR DRAIN
OUT LI NE O F CUTOUT 70.5" x 34.5" (1780 x 876mm)
MODEL SERIES 3574
60"
(1524mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
C
L
42"
(1067mm)
754532-100 Rev. A
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
9"
(229mm)
CUTOUT IN FLOOR FOR DRAIN
OUT LI NE O F CUTOUT 58.5" x 40.5" (1486 x 1029mm)
22
C
L
Page 23
ROUGH-IN REFERENCES
MODEL SERIES 3575
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
72"
(1829mm)
9"
(229mm)
CUTOUT IN FLOOR FOR DRAIN
OUTLINE OF CUTOUT 70.5" x 40.5" (1780 x 1029mm)
14-3/4"
(375mm)
11-1/2"
(292mm)
42"
(1067mm)
C
L
23
754532-100 Rev. A
Page 24
SPECIFICATIONS:
L
W
J
SIDE VIEW
H
END VIEW
C
GENERAL SPECIFICATIONS FOR SERIN WHIRLPOOLS AND BATH TUBS
Description
3581 Serin
5' x 32"
3582 Serin
5-1/2' x 36"
3583 Serin Oval
3584 Serin
6' x 42"
Dimensions
L-W-H
L 60" (1524mm) W 32" (813mm) H 23" (584mm)
L 66" (1676mm) W 36" (914mm) H 23" (584mm)
L 68" (1727mm) W 38" (965mm) H 23" (584mm)
L 72" (1829mm) W 42" (1067mm) H 23" (584mm)
Drain /
Overflow
A 16-3/4" (425mm) B 10-1/4" (260mm)
A 16-7/8" (429mm) B 9-3/4" (248mm)
A 17-1/4" (438mm) B 11-1/2" (292mm)
A 17" (432mm) B 10-1/4" (260mm)
Height to Underside of Deck: C
C 20" (508mm)
C 20" (508mm)
C 20" (508mm)
C 20" (508mm)
Cut Out
Pier
G x F
58-1/2" (1486mm) x 30-1/2" (775mm)
64-1/2" (1638mm) x 34-1/2" (876mm)
Template Provided
70-1/2" (1791mm) x 40-1/2" (1029mm)
Rough-In
Recess
E x D
60-3/16" (1529mm) x 30-1/2" (775mm)
66-3/16" (1681mm) x 34-1/2" (876mm)
68-3/16" (1732mm) x 36-1/2" (927mm)
72-3/16" (1834mm) x 40-1/2" (1029mm)
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
597 lb. (271 kg)/ 45 lb./sq.ft. (219 kg/sq.m)
806 lb. (365 kg)/ 49 lb./sq.ft. (239 kg/sq.m)
680 lb. (308 kg)/ 68 lb./sq.ft. (331 kg/sq.m)
1043lb. (473 kg)/ 50 lb./sq.ft. (243 kg/sq.m)
A
Product
Weight
57 lb. (26 kg.)
65 lb. (29 kg.)
60 lb.
(27 kg.)
68 lb. (31 kg.)
DRAIN / OVERFLOW
B
Gallon to Overflow
54 gal. (246 l.)
97 gal. (441 l.)
90 gal. (409 l.)
125 gal. (568 l.)
Whirlpool Operating
Volume
TABLE 10
9-3/4"
(248mm)
32"
(813mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
ROUGH-IN REFERENCES
MODEL SERIES 3581
C
L
60"
(1524mm)
30"
(762mm)
INTEG RAL FITTI NG DECK
OVERFLOW
OUTLINE OF CUTOUT
4-1/8"
(105mm)
9" x 12" (227 x 305mm)
CUTOUT IN FLOOR FOR DRAIN
754532-100 Rev. A
24
Page 25
9-3/4"
(248mm)
ROUGH-IN REFERENCES
MODEL SERIES 3582
66"
33"
(838mm)
(1676mm)
C/L
DRAIN
9" x 12" (227 x 305mm) FLOOR CUTOUT
4-1/8" (105mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
36"
(914mm)
11-1/2"
(292mm)
4"
(102mm)
MODEL SERIES 3583
68"
34"
(864mm)
(1727mm)
C/L
DRAIN
OUTLINE OF CUTOUT
INTEGRAL FAUCET DECK
9"x12" (227x305mm) FLOOR CUTOUT
4-7/8"
(124mm)
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
INTEGRAL
FAUCET DECK
4-3/4"
(121mm)
OUTLINE OF CUTOUT
USE CUT-OUT TEMPLATE SUPPLLIED WITH PACKAGED TUB
OUTLINE OF SKID RESISTANT SURFACE
25
754532-100 Rev. A
Page 26
PROVIDE ACCESS
TO PUMP
SERVING ON
ALL INSTALLATIONS
10-1/4"
(260mm)
42"
(1067mm)
INTEGRAL
FAUCET DECK
ROUGH-IN REFERENCES
MODEL SERIES 3584
72"
36"
(914mm)
(1829mm)
DRAIN
OUTLINE OF
CUTPUT
C/L
9" x 12" (227 x 305mm) FLOOR CUTOUT
OUTLINE OF SKID RESISTANT SURFACE
4-7/8"
(124mm)
754532-100 Rev. A
26
Page 27
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
!
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
Refer to the schematics below for the appropriate bath electrical installation. Dedicated15A circuits with GFCI (Ground Fault Circuit Interrupter) protection are required.
At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of electrical shock. Turn of the power and do not use until the source of the problem has been identifed and corrected.
ELECTRICAL
FEED
GFCI
ELECTRICAL
FEED
GFCI
AIR SWITCH ACTIVATED WHIRLPOOL PUMP
120V, 60HZ 15A GFCI
120V, 60HZ 15A GFCI
JUNCTION BOX (CANADA)
White
Black
Green/Copper
GFCI OUTLET (USA)
27
754532-100 Rev. A
Page 28
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ELECTRICAL
FEED
GFCI
120V, 60HZ 15A GFCI
ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL)
ELECTRICAL
FEED
ELECTRONIC ACTIVATED AIR BATH WITH LIGHTS (5 BUTTON PANEL)
754532-100 Rev. A
120V, 60HZ 15A GFCI
GFCI
28
Page 29
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ECOSILENT PUMP HAS P3JJ PLUG
ELECTRICAL
FEED
GFCI
120V, 60HZ 15A GFCI
ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL (1 BUTTON PANEL)
ECOSILENT PUMP HAS P3JJ PLUG
ELECTRICAL
FEED
GFCI
120V, 60HZ 15A GFCI
ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL WITH LIGHTS (3 BUTTON PANEL)
29
754532-100 Rev. A
Page 30
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
USE THREE GFCI OUTLETS (USA MARKET)
ELECTRICAL
FEED
GFCI
ELECTRICAL
FEED
GFCI
120V, 60HZ 15A GFCI (FOR HEATER)
120V, 60HZ 15A GFCI
WHIRLPOOL HEATER IS
FACTORY INSTALLED ON
COMBINATION TUBS
ECOSILENT PUMP
HAS P3JJ PLUG
ELECTRICAL
FEED
GFCI
120V, 60HZ 15A GFCI
ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)
754532-100 Rev. A
30
Page 31
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
USE THREE JUNCTION BOXES
(CANADA MARKET)
ELECTRICAL
FEED
GFCI
ELECTRICAL
FEED
GFCI
Green/Copper
Green/Copper
120V, 60HZ 15A GFCI (FOR HEATER)
White
Black
120V, 60HZ 15A GFCI
White
Black
WHIRLPOOL HEATER IS
FACTORY INSTALLED ON
COMBINATION TUBS
TO
BOX
ECOSILENT PUMP
HAS P3JJ PLUG
ELECTRICAL
FEED
GFCI
Green/Copper
120V, 60HZ 15A GFCI
White
Black
ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)
TO
BOX
31
754532-100 Rev. A
Page 32
ELECTRICAL INSTALLATION INSTRUCTIONS (continued)
Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3.
(HEATER)
E-Z INSTALL
HEATER ON
WHIRLPOOL
HEATER
The conductor is secured to the lugs using set screws. The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the home’s electrical panel or approved local bonding point as shown in Figure 3.
NOTE: For all “EcoSilent” pump configurations, the pump housing is plastic. Therefore, the first copper conductor attached to the heater must be grounded directly to the home’s electrical panel or approved local bonding point. this type of configuration does not need the second copper conductor shown in Figure 3.
WHIRLPOOL HEATER OPERATION
WARNING: Prior to operation, review the Important Safety Instructions listed at the beginning of this instruction manual.
Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath.
Pressure Switch
The heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the heater to turn on.
(PUMP/MOTOR)
SECOND COPPER
CONDUCTOR
TO GROUND
RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP/MOTOR FRAME LUG AND FROM PUMP/MOTOR LUG TO APPROVED GROUND AS SHOWN
FIRST COPPER
PUMP/MOTOR FRAME WITH BONDING LUGS
(NOT ON “ECOSILENT” MODELS)
FIGURE 3: GROUNDING DIAGRAM
WHIRLPOOL
HEATER “ON” LIGHT
E-Z INSTALL
FACTORY INSTALLED - NOT FOR RESALE
HEATER P/N: 753174-100
HEATER
FIGURE 4: WHIRLPOOL HEATER INDICATOR LIGHT
CONDUCTOR
Bonding Lug on Heater Housing
Indicator Light
This light turns on whenever the heater is operating.
High-Limit Switch
The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap water. It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician. To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. (2) Drain water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. (4) The heater circuit will automatically reset in less than 15 minutes. (5) Restore power to the heater. (6) Whirlpool bath is now ready to use.
754532-100 Rev. A
32
Page 33
REMOTE BLOWER LOCATION OPTION
IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular
installation makes this effort practical.
NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting
board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final desired position of air blower. Follow all instructions listed below.
TYPICAL VIEW
NOTE: Installing the blower in a remote location will reduce the system efficiency.
NOTE: Relocating a blower motor still requires a service access for the blower.
NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel
cable (754025-0073A), a longer flexible blower hose (753960-2030A), and up to two lighting cable extensions for combo models (754512-0070A).
A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location. Electrical connections should be performed by a licensed electrician.
The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.
1.
Disconnect the blower from the flexible hose as shown in photo 2. Do NOT remove the check valve manifold that is mounted to the underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 2.
2.
TYPICAL VIEW
Replace the flexible hose shown in photo 2 with the longer flexible hose (P/N 753960-2030A) using the existing hope clamps.
NOTE: Do NOT remove the original cable coming out of the blower. Instead, plug the longer cable (P/N 754025-0073A) into the existing cable that is coming out of the blower as shown in photo 3. Then plug the remaining end of the longer cable into the control panel which remains on the tub wall.
TO CONTROL PANEL
Do NOT move check valve manifold
TO BLOWER
3.
754025-0073A CABLE
(INCLUDES ADAPTER
EXISTING CABLE
BOX SHOWN)
33
754532-100 Rev. A
Page 34
REMOTE BLOWER LOCATION OPTION (continued)
FOR THE COMBINATION WHIRLPOOL / AIR BATH CONFIGURATIONS ONLY:
Up to two additional control box extensions (P/N 754512-0070A) are required as shown in photo 4 (below). Simply extend the cables going to the blower by adding in the extension cables. Be careful not to damage the cable connections and never plug in cables while power is applied to blower and/or pump.
4.
PUMP
LONGER CONTROL PANEL CABLE (754025-0073A)
CONTROL PANEL
754532-100 Rev. A
LIGHTS CONTROL BOX EXTENSIONS
(754512-0070A)
34
BLOWER
Page 35
Operation: Single Speed Whirlpool
AIR SWITCH ELECTRONIC SWITCH
BATHING:
• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater, it will automatically maintain the water temperature.
• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.
• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.
• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started. Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.
IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above the highest jet.
STARTING WHIRLPOOL:
• Press on/off button to start whirlpool.
STOPPING WHIRLPOOL:
• Press on/off button again to stop whirlpool.
AIR VOLUME CONTROL ADJUSTMENTS:
• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control counterclockwise for more turbulence, and clockwise for less.
FLOW JET VOLUME ADJUSTMENTS:
• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and clockwise for soft.
The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet
flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.
35
754532-100 Rev. A
Page 36
Operation: EcoSilent Whirlpool with Lights
DISPLAY COLORS
ST
1
3-BUTTON ELECTRONIC SWITCH
BATHING:
• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater, it will automatically maintain the water temperature.
• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.
• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.
• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started. Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.
• IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above the highest jet.
2
3
4
5
6
7
8
9
10
11
ND
TH
TH
TH
TH
TH
TH
TH
TH
TH
RETURN TO SLOW RAINBOW CYCLE
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
WHITE
TURQUOISE
BLUE
MAGENTA
RED
ORANGE
YELLOW
GREEN
To start whirlpool pump, press “on” button.
To stop whirlpool pump, press “off” button.
To turn on Chromatherapy lights, press light button once. The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow cycle and so on per the display color table shown above.
AIR VOLUME CONTROL ADJUSTMENTS:
• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control counterclockwise for more turbulence, and clockwise for less.
FLOW JET VOLUME ADJUSTMENTS:
• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and clockwise for soft.
The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet
flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.
754532-100 Rev. A
36
Page 37
BATHING:
Operation: Air Bath
• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE SYSTEM:
ON/OFF: Press this button once to turn air-blower on.
Press again to turn air-blower off.
AIR SPEED INCREASE: Pressing this button will increase to the next higher speed.
AIR SPEED DECREASE: Pressing this button will decrease to the next lower speed.
WAVE FUNCTION: Press this button to start the wave function (button will light).
Blower speed will continuously vary between high and low. Press again to exit wave function (button light will go out).
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
DRYING CYCLE OPTIONS
STANDARD DRYING CYCLE
An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24 hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.
37
754532-100 Rev. A
Page 38
BATHING:
Operation: Air Bath with Lights
• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:
ON/OFF: Press this button once to turn air-blower on.
Press again to turn air-blower off.
AIR SPEED INCREASE: Pressing this button will increase to the next higher speed.
AIR SPEED DECREASE: Pressing this button will decrease to the next lower speed.
WAVE FUNCTION: Press this button to start the wave function (button will light).
Blower speed will continuously vary between high and low. Press again to exit wave function (button light will go out).
DISPLAY COLORS
ST
1
ND
2
TH
3
TH
4
TH
5
TH
6
TH
7
TH
8
TH
9
TH
10
TH
11
RETURN TO SLOW RAINBOW CYCLE
• To turn on Chromatherapy lights, press light button once.
The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow
cycle and so on per the display color table shown above.
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
WHITE
TURQUOISE
BLUE
MAGENTA
RED
ORANGE
YELLOW
GREEN
754532-100 Rev. A
38
Page 39
Operation: Air Bath with Lights (continued)
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
STANDARD DRYING CYCLE An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24 hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.
DRYING CYCLE OPTIONS
39
754532-100 Rev. A
Page 40
BATHING:
Operation: Combination Tub with Lights
Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWI SE
• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.
OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:
• Press this button to turn blower on.
• Press this button again to turn blower off.
• Press and hold button to increase blower speed. Release button at desired speed.
• Press and hold button to decrease speed. Release button at desired speed.
• Press button to turn whirlpool pump on.
• Press button to turn whirlpool pump off.
DISPLAY COLORS
ST
1
ND
2
TH
3
TH
4
TH
5
TH
6
TH
7
TH
8
TH
9
TH
10
TH
11
RETURN TO SLOW RAINBOW CYCLE
• To turn on Chromatherapy lights, press light button once. The cycle will start on white.
• Turn off and on within 3 seconds; it will change to slow rainbow
cycle and so on per the display color table shown above.
SLOW RAINBOW CYCLE
FAST RAINBOW CYCLE
WHITE
TURQUOISE
BLUE
MAGENTA
RED
ORANGE
YELLOW
GREEN
754532-100 Rev. A
40
Page 41
Operation: Combination Tub with Lights (continued)
EXITING THE BATH
• Be sure to turn off the air blower before draining bath.
• Open drain by rotating drain knob clockwise.
STANDARD DRYING CYCLE An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the purge cycle.
24H PROGRAMMABLE DRYING CYCLE
The system must be stopped prior to activation or deactivation.
Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24 hrs. In the event of a power failure, the program will be automatically deactivated.
Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.
DRYING CYCLE OPTIONS
41
754532-100 Rev. A
Page 42
Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and maintenance.
Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its lasting luster with proper care and maintenance.
CLEANING AND MAINTENANCE:
Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.
Remove bath mat after use and hang to dry. Allowing bath mat to dry in the tub may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not turn on jets when such cleaners are present.
Do not use: Lestoil® Cleaner; Lysol® Disinfectant (spray or concentrate); or Lysol® Basin, Tub and Tile Cleaner; Windex® Cleaner; Mr. Clean® Cleaner; Dow® Disinfectant Bathroom Cleaner*; or other cleaning products in aerosol cans.
HARSH CHEMICALS, SHARP AND ABRASIVE OBJECTS
SHOULD NEVER BE USED ON ACRYLIC SURFACES
• Do not use wire brushes, knives or sharp objects to remove stains or other surface blemishes.
• Use of abrasive cleaners or powders will dull the surface. If the glossy surface looses its sheen, dulled areas can
be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax.
Do not wax surfaces where you walk or stand.
• Do not allow nail polish remover, acetone, dry-cleaning fluid, paint remover, or other solvents to come into contact with the surface.
• Clean the surrounding surface immediately after using caustic drain cleaners.
Do not permit drain cleaner to enter circulation system.
• Burning cigarettes will irreparably damage the surface of the whirlpool.
CLEANING/PURGING THE CIRCULATION SYSTEM
Once every month the circulating system must be purged and cleaned. Follow the steps outlined below:
Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher (not laundry)
1.
detergent and one-half cup of household bleach to filled whirlpool.
Activate whirlpool system in accordance with operating instructions and run system for two minutes.
2.
Drain and refill whirlpool with cold water. Circulate for five minutes.
3.
Drain whirlpool completely after step 3 (above) is completed.
4.
For Troubleshooting and Repair Parts please log on to www.americanstandard-us.com
* Lestoil® is a registered trademark of The Clorox Company. Lysol® is a registered trademark of The Linden Company. Windex® is a registered trademark of S.C. Johnson and Son, Inc. Mr. Clean® is a registered trademark of The Proctor and Gamble Company. Dow® is a registered trademark of The Dow Chemical Company.
754532-100 Rev. A
42
Page 43
AS America, Inc. Limited Lifetime Warranty for Premium Acrylic Air Baths
AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option, repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment, to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser.
This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof of purchase.
This limited warranty does not apply to commercial installations. The warranty for commercial installations is three (3) years.
THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS. In no event will American Standard be liable for the cost of repair or replacement of any installation materials including but not limited to tiles, marble etc.
This limited warranty DOES NOT COVER the following:
1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of proper maintenance and cleaning as directed in the owner’s manual and use of other than genuine American Standard replacement parts, in all cases whether caused by a plumbing contractor, service company, the owner or any other person.
2. Deterioration through normal wear and tear and the expense of normal maintenance.
3. Commercial application.
4. Options and accessories. American Standard’s limited warranty on these items is one year for parts only and excludes labor. This one year limited warranty covers accessories manufactured by American Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against defects of material or workmanship. Warranty coverage begins on the date the accessory was originally purchased by the owner.
5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty.
6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED, OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these limitations and exclusions may not apply to you.)
7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly distrib
utors, retailers, dealers, installation contractors and users of plumbing products should determine
whether there are any code restrictions on the installation or use of a specific product.)
This warranty gives you specific legal rights. You may have other legal rights that vary from state to state. For service under this warranty, you should contact the following:
By Mail: American Standard Brands P.O. Box 6820 Piscataway, N.J. 08855 Attention: Customer Care Center
43
By Telephone:
1-800-442-1902
754532-100 Rev. A
Page 44
754532-100 Rev. A
44