REMINISCENCE
DROP-IN™
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
330mm
(13)
457mm
(18)
914mm
(36)
INTEGRAL
FITTING DECK
152mm
(6)
C/L OF OVERFLOW
149mm REF.
(5-7/8)
RIM AT
DRAIN END
C/L OF
DRAIN
OUTLET
229 x 305mm
(9 X 12)
FLOOR
CUTOUT
ON/OFF
SWITCH
64mm REF.
(2-1/2)
OUTLINE OF
2908.XXXW SERIES
WHIRLPOOL
INSTALLATION INSTRUCTIONS
1676mm
(66)
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
* see your American Standard Distributor
CUTOUT
SAFE-T-HEATER
REMOVABLE BLANK
LEVELING STRINGER
(NOT FOR SUPPORT)
PROVIDE ACCESS
TO PUMP FOR SERVICE
ON ALL INSTALLATIONS
73mm
(2-7/8)
PUMP
INTEGRAL
SUPPORT
FEET
79mm
(3-1/8)
ROUGH
FLOOR
1-1/2 N.P.T.M. THREADS
1-1/2 O.D.TAILPIECE
70mm
(2-3/4)
464mm
(18-1/4)
117mm
(4-5/8)
616mm
(24-1/4)
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
GENERAL SPECIFICATIONS FOR 2908 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
SYSTEM I PUMP
SYSTEM II PUMP
WHIRLPOOL ELECTRICAL SPECIFICATIONS
66 x 36 x 24-1/4 In. (1676 x 914 x 616mm)
40 x 18 In. (1016 x 457mm)
53 x 28 In. (1330 x 718mm)
40 Lbs./Sq. Ft. (191 Kgs/Sq. m.)
95 Lbs. (43 Kg.)
659 Lbs. (299 Kg.)
68 Gal. (257 L.)
55 Gal. (208 L.)
15 In. (381mm)
23.8
44.5
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 or 20 amp
GFI Outlet
• Cement, Plaster,
Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752535-100 Rev. F
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
2. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
3. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
SEE TEMPLATE
18-1/4
(464mm)
MOUNTING SURFACE
WATERPROOF
SEALANT
BATH
SEE CUTOUT TEMPLATE
PROVIDED.
AS DESIRED
SEE TEMPLATE
24
(610mm)
ACCESS PANEL
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
12
(305 mm)
752535-100 Rev. F
(2)