GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
3
CUBE (FT
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP 1.6 HP, 9.7 AMPS,120V.
C/L OF DRAIN
OUTLET
102mm
(4)
19mm
(3/4)
32mm
(1-1/4)
235mm
(9-1/4)
711mm
1676mm
(66)
FINISHED
WALL
229 X 305mm
(9 X 12) FLOOR CUTOUT
(28)
203mm
(8)
(2-3/4)
66 x 32 x 20 In. (1676 x 813 x 508mm)
OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT
ON/OFF
SWITCH
PUMP
FINISHED
WALL
32mm (1-1/4) DIA. HOLE
1/2 N.P.T. SHOWER
44mm (1-3/4) DIA. HOLES
FOR CONTROL VALVES
32mm (1-1/4) DIA. HOLE FOR
1/2 N.P.T. SPOUT
70mm
32mm
(1-1/4)
SUPPORT
STRINGER
117mm (4-5/8)
201 Lbs. (90 Kg.)
701 Lbs. (315 Kg.)
60 Gal. (227 L)
42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)
55 Lbs./Sq.Ft. (223 Kgs./Sq.m)
40 Gal. (152 L)
14 In. (356mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
1651-1982mm
(65-78)
OPTIONAL
508mm
(20)
476mm
(18-3/4)
MIN.
13.9
33.7
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
791031-100 Rev. H
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
FRAMING AND INSTALLATION
THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST
BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ANY FINISH MATERIAL, SUCH
AS TILE OR WALLBOARD, MUST BE SELF SUPPORTING IF IT CONTACTS THE RIM OF BATH.
TYPICAL RECESS INSTALLATION
476mm
(18-3/4)
1680mm
(66-1/8)
TILE
TILE BEAD
STRIP
SEALANT
ADHESIVE
LEVELING
STRINGER
762mm
(30)
813mm
(32)
TUB WIDTH
LEVELING
STRINGERS
610 mm
(24)
BATH
WHIRLPOOL ONLY:
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
305mm
(12)
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
775mm
(30-1/2)
CUTOUT
476mm
(18-3/4)
LEVELING
SURFACE
WATERPROOF
SEALANT
1638mm
(64-1/2)
CUTOUT
AS
DESIRED
610mm
ACCESS PANEL
BATH
WHIRLPOOL ONLY:
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
(24)
305mm
(12)
791031-100 Rev. H (2)
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the
electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded
neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE
15 AMP MAXIMUM GFCI CIRCUIT.
ELECTRICAL INSTALLATION
120 VAC
WHITE
GND.
SEPARATE 15 AMP
GFCI OUTLET
WHIRLPOOL MOUNTED
AIR SWITCH or
WALL TIMER
BLACK
PUMP/MOTOR
791031-100 Rev. H
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
(3)
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
Motor
Hi-Performance
50' 100'
150' 200'
Rating
120V Power Line
1.6
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings
are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
POST INSTALLATION CLEAN-UP
12 12 10 8
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or
stains may be removed using granular Spic and Span® mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ENAMEL SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing
with a white automotive-type polishing compound and waxing with a liquid wax.
791031-100 Rev. H