American Standard 2470.XXXW User Manual

STRATFORD™
AMERICAST BRAND ENGINEERED MATERIAL
2470.XXXW SERIES WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
C/L OF 1/2 SUPPLIES
AS REQUIRED
76mm
(3)
813mm
(32)
203mm
(8)
406mm
(16)
C/L OF SHOWER
CURTAIN ROD
1930mm (76)
OPTIONAL TO FLOOR
SAFE-T-HEATER
REMOVABLE BLANK
1/2 SUPPLIES
AS REQ'D
324mm
(12-3/4)
70mm
(2-3/4)
C/L OF OVERFLOW
1-1/2 N.P.T. THREADS
1-1/2 O.D. TAILPIECE
GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW WHIRLPOOL MIN. OPERATING VOL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS.
3
CUBE (FT
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP 1.6 HP, 9.7 AMPS,120V.
C/L OF DRAIN OUTLET
102mm (4)
19mm (3/4)
32mm (1-1/4)
235mm
(9-1/4)
711mm
1676mm
(66)
FINISHED WALL
229 X 305mm (9 X 12) FLOOR CUTOUT
(28)
203mm (8)
(2-3/4)
66 x 32 x 20 In. (1676 x 813 x 508mm)
OUTLINE OF 1638 X 775mm (64-1/2 X 30-1/2) CUTOUT
ON/OFF
SWITCH
PUMP
FINISHED WALL
32mm (1-1/4) DIA. HOLE 1/2 N.P.T. SHOWER
44mm (1-3/4) DIA. HOLES FOR CONTROL VALVES
32mm (1-1/4) DIA. HOLE FOR 1/2 N.P.T. SPOUT
70mm
32mm (1-1/4)
SUPPORT STRINGER
117mm (4-5/8)
201 Lbs. (90 Kg.)
701 Lbs. (315 Kg.)
60 Gal. (227 L)
42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)
55 Lbs./Sq.Ft. (223 Kgs./Sq.m)
40 Gal. (152 L)
14 In. (356mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
1651-1982mm
(65-78)
OPTIONAL
508mm
(20)
476mm (18-3/4)
MIN.
13.9
33.7
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
* see your American Standard Distributor List of Required Components (not included):
• Drain 1583.470*
• Bath Filler* * see your American Standard Distributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4 Stringers
• Drop Cloth
• 15 amp GFCI Outlet
• Cement, Plaster, Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
791031-100 Rev. H
© American Standard Inc. 2005 All product names listed herein are trademarks of American Standard Inc. unless otherwise noted.
FRAMING AND INSTALLATION
THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST
BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ANY FINISH MATERIAL, SUCH AS TILE OR WALLBOARD, MUST BE SELF SUPPORTING IF IT CONTACTS THE RIM OF BATH.
TYPICAL RECESS INSTALLATION
476mm (18-3/4)
1680mm (66-1/8)
TILE
TILE BEAD STRIP
SEALANT
ADHESIVE
LEVELING STRINGER
762mm
(30)
813mm
(32)
TUB WIDTH
LEVELING STRINGERS
610 mm
(24)
BATH
WHIRLPOOL ONLY: UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610MM) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
305mm
(12)
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
775mm
(30-1/2)
CUTOUT
476mm
(18-3/4)
LEVELING SURFACE
WATERPROOF SEALANT
1638mm
(64-1/2)
CUTOUT
AS
DESIRED
610mm
ACCESS PANEL
BATH
WHIRLPOOL ONLY: UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610MM) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
(24)
305mm
(12)
791031-100 Rev. H (2)
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE
15 AMP MAXIMUM GFCI CIRCUIT.
ELECTRICAL INSTALLATION
120 VAC
WHITE
GND.
SEPARATE 15 AMP
GFCI OUTLET
WHIRLPOOL MOUNTED
AIR SWITCH or
WALL TIMER
BLACK
PUMP/MOTOR
791031-100 Rev. H
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
(3)
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
Motor
Hi-Performance
50' 100'
150' 200'
Rating
120V Power Line
1.6
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running.
POST INSTALLATION CLEAN-UP
12 12 10 8
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ENAMEL SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-type polishing compound and waxing with a liquid wax.
791031-100 Rev. H
(4)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE