CAMBRIDGE™
AMERICAST BRAND ENGINEERED MATERIAL
2460.XXXW SERIES 2461.XXXW SERIES WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
|
|
|
|
1524mm |
|
|
|
|
|
|
203mm |
(60) |
|
|
|
|
19mm |
|
|
70mm |
|
|
|
|
|
(8) |
FINISHED |
|
|
||
|
|
(2-3/4) |
|
|
|||
|
(3/4) |
|
|
WALL |
|
SERVICING ON ALL INSTALLATIONS |
|
|
|
|
|
PROVIDE ACCESS TO PUMP FOR |
|||
406mm |
102mm |
|
|
PUMP |
|||
(16) |
|
|
|||||
(4) |
|
|
|
||||
|
|
|
|
|
|||
|
|
|
|
229mm x 305mm |
|
||
|
|
|
|
(9 x 12) |
|
||
|
102mm |
|
|
FLOOR |
|
||
|
|
|
CUTOUT |
|
|||
|
(4) |
|
|
|
|||
813mm |
|
|
|
ON / OFF |
|||
|
|
|
|
||||
(32) |
|
|
|
|
SWITCH |
||
|
|
|
|
|
|||
|
60mm+13mm |
|
|
|
|||
|
|
|
|
|
|
||
|
(2-3/8)+(1/2) |
|
|
|
|
|
|
|
|
|
25mm |
64mm |
|
|
|
C/L OF 1/2 |
|
(1) |
(2-1/2) |
|
|
|
|
|
C/L OF |
|
|
|
|
||
SUPPLIES |
|
|
|
|
|
||
|
DRAIN |
|
|
|
|
||
AS REQ'D |
|
|
|
|
|
||
|
|
|
|
|
|
SHOWER ARM- 1/2 N.P.T.
32mm(1-1/4) DIA. HOLE
C/L OF CURTAIN ROD |
|
711mm |
|||
USUALLY 1930mm(76) FROM |
|
|
|
|
|
|
|
|
(28) |
||
FINISHED FLOOR |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
FINISHED |
|
C/L OF |
(2) 54mm(2-1/8) |
|
102mm |
|
WALL |
|
|
VALVES |
|
(4) |
|
|
||
|
|
DIA. HOLES |
|
|
|
|
|
OPTIONAL |
|
|
102mm |
SPOUT- |
|
|
|
TO FLOOR |
|
102mm |
|
|
|||
406mm |
|
(4) |
1/2 N.P.T. |
|
SAFE-T-HEATER |
||
USUALLY |
(4) |
|
|
||||
(16) |
|
|
76mm |
|
|||
BETWEEN |
|
|
|
|
REMOVABLE BLANK |
||
1651 & 1981mm |
|
|
|
|
(3) |
|
|
(65 & 78) |
24mm |
|
|
|
|
■ |
|
|
|
|
|
|
|
||
|
(15/16) |
|
|
|
|
SEE |
441mm |
|
451mm |
|
|
|
|
||
|
|
|
|
|
NOTE |
||
|
|
|
|
|
(17-3/8) |
||
|
(17-3/4) |
|
|
|
|
||
|
|
|
|
|
|
||
|
|
|
|
|
70mm |
||
|
|
|
|
|
|
||
|
|
|
|
|
|
(2-3/4) |
|
|
|
|
|
|
|
|
ROUGH |
|
|
117mm |
|
|
|
|
FLOOR |
|
|
|
|
1-1/2 N.P.T. THREADS |
|||
|
|
(4-5/8) |
|
|
|||
|
|
|
|
1-1/2 O.D. TAILPIECE |
|||
|
|
|
|
|
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
•Drain 1583.470*
•Bath Filler*
* see your American Standard Distributor
GENERAL SPECIFICATIONS FOR 2460/2461 WHIRLPOOL
INSTALLED SIZE |
|
|
|
|
60 x 32 x 17-3/4 In. (1524 x 813 x 451mm) |
||||||||||||||
|
|
|
|||||||||||||||||
WEIGHT |
|
|
|
|
|
|
|
|
|
190 Lbs. (86 Kg.) |
|||||||||
WEIGHT w/WATER |
|
|
|
|
|
|
607 Lbs. (273 Kg.) |
||||||||||||
GAL. TO OVERFLOW |
|
|
|
|
|
|
|
|
|
|
50 Gal. (190 L) |
||||||||
WHIRLPOOL MIN. OPERATING VOL. |
|
|
|
|
|
39 Gal. (148 L) |
|||||||||||||
|
|
|
|
|
|||||||||||||||
BATHING WELL AT SUMP |
|
|
|
|
41 x 20 In. (1041 x 508mm) |
||||||||||||||
|
|
|
|
||||||||||||||||
BATHING WELL AT RIM |
|
|
|
|
|
54 x 26 In. (1372 x 660mm) |
|||||||||||||
|
|
|
|
|
|||||||||||||||
WATER DEPTH TO OVERFLOW |
|
|
|
|
|
|
14 In. (356mm) |
||||||||||||
|
|
|
|
|
|
||||||||||||||
FLOOR LOADING |
|
|
|
|
46 Lbs./Sq.Ft. (220 Kgs./Sq.m) |
||||||||||||||
|
|
|
|
||||||||||||||||
(PROJECTED AREA) |
|
|
|
|
|
|
|
|
|
|
|||||||||
PTS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15.6 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
CUBE (FT3) |
|
|
|
|
31.5 |
||||||||||||||
|
|
|
|
||||||||||||||||
|
|
|
WHIRLPOOL ELECTRICAL SPECIFICATIONS |
||||||||||||||||
SYSTEM I PUMP |
|
|
|
|
1.6 HP, 9.7 AMPS,120V. |
||||||||||||||
SAFETY HEATER |
|
|
|
|
|
|
12 AMPS, 120V. |
GENERAL INSTALLATION INFORMATION
List of Required Tools and Supplies:
Tools |
Supplies |
||
• |
Level |
• |
Nails |
• |
Tape Measure |
• |
Putty |
• |
Pipe Wrench |
• |
Caulking (waterproof) |
• |
Slip Joint Pliers |
• |
1 x 3 or 2 x 4 |
• |
Screw Driver |
|
Stringers |
• |
Standard |
• |
Drop Cloth |
|
Woodworking Tools |
• |
15 amp GFCI |
• |
Personal Safety |
|
Outlet |
|
Equipment |
• |
Cement, Plaster, |
• |
Caulking Gun |
|
Grout |
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© American Standard Inc. 2003
791033-100 Rev. I All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
FRAMING AND INSTALLATION
BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS INSTALLATION DIAGRAM.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST
BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: LEVELING SUPPORT STRINGER SHOULD BE AS INDICATED. THE BATH IS SUPPORTED FROM THE APRON AND THE REAR TILING FLANGE. NO SUPPORT UNDER THE SUMP IS NECESSARY.
POSITION BATHTUB/WHIRLPOOL WITHIN THE RECESS, CHECK LEVEL, FRONT TO BACK, SIDE TO SIDE, AND SHIM AS NECESSARY. ALSO CHECK DRAIN CLEARANCE HOLE IN THE SUBFLOOR.
TO SECURE THE TUB TO WOOD STUDS USE ROOFING NAILS IMMEDIATELY ABOVE THE FLANGE OF THE TUB. TO SECURE THE TUB TO STEEL STUDS USE DRYWALL SCREWS AND FLATWASHERS.
CAUTION: TAKE EXTRA CARE WHEN DRIVING NAILS OR SCREWS TO AVOID DAMAGING THE TUB.
THE TILE OR SIMILAR FINISHED FLOOR WILL BE BUTTED AGAINST THE BOTTOM OF THE TUB APRON, ALSO HOLDING THE TUB IN PLACE.
TYPICAL RECESS INSTALLATION
441mm (17-3/8)
1527mm (60-1/8)
|
|
|
|
m |
|
|
|
m |
|
|
3 |
|
||
1 |
|
|
) |
|
8 |
|
|
|
|
|
|
|
2 |
|
|
|
3 |
WIDTH |
|
|
( |
|
|
|
TUB |
|
229 X 305mm (9 X 12) FLOOR CUTOUT
305mm
(12)
610 mm
(24)
WHIRLPOOL ONLY:
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
SUGGESTED WHIRLPOOL/BATH INSTALLATION METHOD
WOOD STUDS
STUD
SHIM
DRY WALL
TILE
ROOFING NAIL
SEALANT
TUB
51 x 102mm (2 x 4) WOOD
STRINGER FULL LENGTH
STEEL STUDS
STEEL
STUD
SHIM
WASHER
DRY WALL
TILE
SEALANT
4" (102mm) DRYWALL
SCREW
TUB
51 x 102mm (2 x 4) WOOD
STRINGER FULL LENGTH
SECURE THE BATH TO THE STUDS
AS SHOWN FOR WOOD OR STEEL STUD
CONSTRUCTION.
791033-100 Rev. I |
(2) |
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1.DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2.Grounding is required. The unit should be installed by a licensed electrician and grounded.
3.Install to permit access for servicing.
4.All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. ADDING THE SAFE-T-HEATER REQUIRES A SEPARATE
15 AMP MAXIMUM GFCI CIRCUIT.
ELECTRICAL INSTALLATION |
|
|
SEPARATE 15 AMP |
|
GFCI OUTLET |
|
120 VAC |
|
WHIRLPOOL MOUNTED |
|
AIR SWITCH or |
|
WALL TIMER |
WHITE |
BLACK |
|
PUMP/MOTOR |
|
GND. |
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
791033-100 Rev. I |
(3) |
WIRE SELECTION GUIDE |
|
|
|
|
||
|
|
|
|
|
|
|
|
Maximum distance from |
The sizes shown on this |
||||
|
|
fusebox to motor |
|
|||
Motor |
|
|
|
|
|
chart are recommendations |
50' |
100' |
150' |
|
200' |
||
Hi-Performance |
|
for copper conductors |
||||
Rating |
|
|
|
|
|
only. Always follow |
|
120V Power Line |
|
||||
|
|
|
local and national |
|||
1.6 |
12 |
12 |
10 |
|
8 |
electrical codes |
|
|
|||||
|
|
|
|
|
|
|
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running.
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ENAMEL SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-type polishing compound and waxing with a liquid wax.
791033-100 Rev. I |
(4) |
SPIC AND SPAN |
® |
IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE |
|
|