American Standard 2397.202TC, 2394, 2396.202, 2396.202TC, 2397.202 User Manual

...
PRINCETON™ RECESS BATH W/ LUXURY LEDGE
BARRIER FREE
Americast® brand engineered material
2395.202 Right Hand Outlet ❏ 2395.202TC Same as above w/tub cover ❏ 2394.202 Left Hand Outlet ❏ 2394.202TC Same as above w/tub cover
• Acid resistant porcelain nish
• Recess bath with integral apron and tiling ange
• Integral lumbar support
• Extra wide ledge for placement of toiletries
• Beveled headrest
• Full slip-resistant coverage
• End drain outlet
PRINCETON™ RECESS BATH W/ LUXURY LEDGE for Above Floor Rough Installations
2396.202 Left Hand Outlet for above
oor installation
2396.202TC Same as above w/tub cover ❏ 2397.202 Right Hand Outlet for above
oor installation
2397.202TC Same as above w/tub cover
PRINCETON™ RECESS BATH
WITH LUXURY LEDGE
AMERICAST® BRAND ENGINEERED MATERIAL
To Be Specied:
Color: Bath Faucet*: Faucet Finish: Drain: 1583.470 Drain Finish:
*See faucet section for additional models available
Nominal Dimensions: 1524 x 864 x 356mm (445mm for above oor installation) (60" x 34" x 14") (17-1/2" for above oor installation)
Bathing Well Dimensions: 1423 x 635 x 337mm (56" x 25" x 13-1/4")
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.4 for Americast Plumbing Fixtures
• ASTM F-462 for Slip-resistant Bathing Facilities
• ANSI Z124.1 Ignition Test
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
Americast® brand engineered material is a composition of porcelain bonded to enameling grade metal, bonded to a patented structural composite.
SEE REVERSE FOR PRODUCT DIMENSIONS AND SPECIFICATIONS
© 2008 AS America Inc.
H117
Revised 2/08
PRINCETON™ RECESS BATH
152 4mm
(60 )
864 mm
(34 )
32m m
(1- 1/4)
FIN ISHED
WAL L
19m m (3/ 4)
FINISHED WALL
C/L OF DRAIN
197 mm (7- 3/4)
ROU GH FLO OR
356 mm
(14 )
FIN ISHED WAL L
464m m
(18- 1/4)
149 mm
(5- 7/8)
SEE FITTING SPECS
FOR DIMENSION
C/L OF
SPO UT
C/L OF
VAL VES
C/L OF SHO WER AR M
346 mm
(13 -5/8)
25m m (1)
165 1-1981 mm
(65 -78)
OPT IONAL
70m m
(2- 3/4)
117 mm
(4- 5/8)
1-1/ 2 N.P. T.
THRE ADS
1-1/ 2 O.D.
TAIL PIECE
102m m (4)
64mm
(2-1 /2)
305 mm
(12 )
SEE NOT E
89m m
(3- 1/2)
C/L OF
SUP PLIES
229mm x 305mm (9 x 12) CUTOUT
TIL ING FL ANGE
GENERAL SPECIFICATIONS FOR 2394/2395 BATHING POOL
60 x 34 x 14 In. (1524 x 864 x 356mm)
118 Lbs. (54 Kg.)
468 Lbs. (213 Kg.)
42 Gal. (159 L) 42 x 19 In. (1067 x 483mm) 56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
33 Lbs./Sq.Ft. (159 Kgs./Sq.m)
6.7
20.1
INSTAL LED SIZE WEIGHT WEIGHT w/WATER GAL. T O OVERFLOW BATHIN G WELL AT SUMP BATHIN G WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJE CTED AREA) PTS. CUBE ( FT3)
GENERAL SPECIFICATIONS FOR 2396/2397 BATHING POOL
60 x 34 x 17-1/2 In. (1524 x 864 x 445mm)
126 Lbs. (57 Kg.)
476 Lbs. (216 Kg.)
42 Gal. (159 L)
42 x 19 In. (1067 x 483mm) 56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
34 Lbs./Sq.Ft. (163 Kgs./Sq.m)
8.1
24.1
INSTAL LED SIZE WEIGHT WEIGHT w/WATER GAL. T O OVERFLOW BATHIN G WELL AT SUMP BATHIN G WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJE CTED AREA) PTS. CUBE ( FT3)
STUD
SHIM
DRY WA LL
TILE
SEALAN T
TUB
ROOFIN G NAI L
STEEL
STUD
SHIM
DRY WA LL
WASHER
TILE
SEALAN T
TUB
4" (10 2mm) DRYWAL L SCREW
WOOD STUD S STEEL STU DS
Below is shown typical cross sections of the tub
rim showing typical wall constructions.
51 x 102mm (2 x 4) WOOD STRIN GER F ULL L ENGT H
BARRIER FREE
WITH LUXURY LEDGE
AMERICAST® BRAND ENGINEERED MATERIAL
NOTE: Dimensions shown for 2394/2395 only. Refer to installation instruction for 2392/2393 above oor installation.
© 2008 AS America Inc.
NOTES:
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS. (2395.202).
SHOWN WITH POP-UP C.D. & O.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH FITTING.
CONCEALED PIPING NOT FURNISHED.
BATH FAUCET NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.4 These measurements are subject to change or cancellation. No responsibilit y is assumed for use of superseded or voided leaet.
H118
Revised 2/08
Loading...