American Standard 2391.202TC, 2392.202TC, 2390.202TC User Manual

PRINCETON™ RECESS BATH
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USEABLE BUILDING FACILITIES-CHECK LOCAL CODES. INSTALL WITH SEAT AT HEAD END.
BARRIER FREE
Americast® brand engineered material
2391.202 Right Hand Outlet ❏ 2391.202TC Same as above w/tub cover ❏ 2390.202 Left Hand Outlet ❏ 2390.202TC Same as above w/tub cover
• Acid resistant porcelain nish
Recess bath with integral apron and tiling ange
• Integral lumbar support
• Beveled headrest
• Full slip-resistant coverage
• End drain outlet
PRINCETON™ RECESS BATH for Above Floor Rough Installation
2392.202 Left Hand Outlet for above
oor installation
2392.202TC Same as above w/tub cover ❏ 2393.202 Right Hand Outlet for above
oor installation
2393.202TC Same as above w/tub cover
Nominal Dimensions:
1524 x 762 x 356mm (445mm for above oor installation) 60" x 30" x 14" (17-1/2” for above oor installation)
PRINCETON™
RECESS BATH
AMERICAST® BRAND ENGINEERED MATERIAL
To Be Specied - Required:
Color: Bath Faucet*: Faucet Finish: Drain: 1583.470 Drain Finish:
*See faucet section for additional models available
Bathing Well Dimensions: 1423 x 635 x 337mm (56" x 25" x 13-1/4")
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.4 for Americast Plumbing Fixtures
• ASTM F-462 for Slip-resistant Bathing Facilities
• ANSI Z124.1 Ignition Test
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
Americast® brand engineered material is a composition of porcelain bonded to enameling grade metal, bonded to a patented structural composite.
SEE REVERSE FOR PRODUCT DIMENSIONS AND SPECIFICATIONS
© 2008 AS America Inc.
H111
Revised 2/08
229mm x 305mm (9 x 12) CUTOUT
152 4mm
(60 )
762 mm
(30 )
32m m
(1- 1/4 )
FIN ISH ED
WAL L
19m m (3/ 4)
FINISHED WALL
C/L OF DRAIN
197 mm (7- 3/4 )
ROU GH
FLO OR
356 mm
(14 )
FIN ISH ED WAL L
362 mm
(14 -1/ 4)
48m m
(1- 7/8 )
SEE FITTING SPECS
FOR DIMENSION
C/L OF
SPO UT
C/L OF
VAL VES
C/L OF SHO WER ARM
346 mm
(13 -5/ 8)
25m m (1)
165 1-1 981mm
(65 -78 )
OPT ION AL
70m m
(2- 3/4 )
117 mm
(4- 5/8 )
1-1 /2 N.P .T.
THR EAD S
1-1 /2 O.D .
TAI LPI ECE
102 mm (4)
64m m
(2- 1/2 )
305 mm
(12 )
SEE NOT E
89m m
(3- 1/2 )
C/L OF
SUP PLI ES
TIL ING FLAN GE
GENERAL SPECIFICATIONS FOR 2390/2391 BATHING POOL
60 x 30 x 14 In. (1524 x 762 x 356mm)
110 Lbs. (50 Kg.)
460 Lbs. (209 Kg.)
42 Gal. (159 L) 42 x 19 In. (1067 x 483mm) 56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
37 Lbs./Sq.Ft. (175 Kgs./Sq.m)
6.2
18.1
INSTAL LED SIZE WEIGHT WEIGHT w/WATER GAL. T O OVERFLOW BATHIN G WELL AT SUMP BATHIN G WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJE CTED AREA) PTS. CUBE ( FT3)
GENERAL SPECIFICATIONS FOR 2392/2393 BATHING POOL
60 x 30 x 17-1/2 In. (1524 x 762 x 445mm)
119 Lbs. (54 Kg.)
469 Lbs. (213 Kg.)
42 Gal. (159 L) 42 x 19 In. (1067 x 483mm) 56 x 25 In. (1423 x 635mm)
9-1/2 In. (241mm)
38 Lbs./Sq.Ft. (182 Kgs./Sq.m)
7.4
21.2
INSTAL LED SIZE WEIGHT WEIGHT w/WATER GAL. T O OVERFLOW BATHIN G WELL AT SUM P BATHIN G WELL AT RIM WATER DEPTH TO OVER FLOW FLOOR LOADING (PROJE CTED AREA) PTS. CUBE ( FT3)
STUD
SHIM
DRY WA LL
TILE
SEALAN T
TUB
ROOFIN G NAI L
STEEL
STUD
SHIM
DRY WA LL
WASHER
TILE
SEALAN T
TUB
4" (10 2mm) DRYWAL L SCREW
WOOD STUD S STEEL STU DS
Below is shown typical cross sections of the tub
rim showing typical wall constructions.
51 x 102mm (2 x 4) WOOD STRIN GER F ULL L ENGT H
PRINCETON™
BARRIER FREE
RECESS BATH
AMERICAST® BRAND ENGINEERED MATERIAL
NOTE: Dimensions shown for 2390/2391 only. Refer to installation instruction for 2392/2393 above oor installation.
© 2008 AS America Inc.
NOTES:
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS. (2391.202).
SHOWN WITH POP-UP C.D. & O.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH FITTING.
CONCEALED PIPING NOT FURNISHED.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.4 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.
H112
Revised 2/08