American Standard 2390.202 User Manual

AMERICAST® LIMITED LIFETIME WARRANTY
If an American-Standard Americast® brand product is found to be defective in materials or workmanship, after inspection by an authorized American-Standard representative, American-Standard will repair or, at its option, exchange the product for a similar model. This warranty extends for the lifetime of the product, so long as it remains in use in its original place of installation, except that the warranty applies to a bathing vessel’s slip-resisting surface only for the first year after the product’s initial installation.
This warranty applies only to the original purchaser and installation of these products.
This warranty does not apply to whirlpool components or to faucets, drains, mounting rims, grab bars or other accessories. If manufactured or supplied by American-Standard, such whirlpool components and accessories are covered under separate limited warranties.
This warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser of this product should check with a local building or plumbing contractor to assure local code compliance before installation.
This warranty shall be void if the Americast® brand product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American­Standard’s instructions; or if it was modified in a manner inconsistent with the product as shipped by American-Standard.
American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor shall American-
Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or
provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case this warranty does not affect such statutory rights.
For service under these warranties, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following address:
In the United States:
AMERICAN STANDARD, INC.
P.O. Box 6820
Piscataway, New Jersey 08855
Attn: Director of Consumer Affairs
For residents of the United States, warranty information may also be obtained by
calling the following toll free number: (800)442-1902
In Canada:
AMERICAN STANDARD, INC.
2480 Stanfield Road
Mississauga, Ontario Canada L4Y 1S2
Toll Free: (800) 387-0369
In Mexico:
IDEAL STANDARD, S.A. de C.V
Customer Service Manager
Planta Santa Clara,Via Morelos #330
Santa Clara Coatitla
Ecatepec de Morelos 55540,
Estado de Mexico, Mexico
Princeton™ Bath
2390.202
2392.202
2391.202
2393.202
Installation Instructions
Observe Local Plumbing and Building Codes
Introduction: Thank you for selecting American-Standard...products which
have been the benchmarks of fine quality for over 100 years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also carefully unpack and examine your new plumbing fixture.
1
FRAMING INSTRUCTIONS
Note recess is 1527 x 813mm (60-1/8 x 32). Cut a 229 x 305mm (9 x 12) hole in sub floor for drain, centered 362mm (14-1/4) as shown for below floor rough. Locate studs as required, then ensure rough opening dimensions are proper and supports are plumb and square.
*Install stringer as shown (346mm [13-5/8] for through the floor drain or
435mm [17-1/8] for above the floor drain.)
813mm
(32)
LEVELING SUPPORT STRINGER 51 x 102mm (2 X 4)
229 x 305mm
(9 x 12) FLOOR
CUTOUT
FOR DRAIN
*
762mm
(30)
362mm
(14-1/4)
1527mm
(60-1/8)
TUB WIDTH
© American Standard Inc. 2002
790043-400 (Rev. G )
AMERICAN STANDARD
2
AMERICAN STANDARD
DRAIN
Install the overflow and drain assembly onto the tub per manufacturer's instructions.
FINISHED
WALL
3
Position bathtub within the recess, check level, front to back, side to side. Also check drain clearance hole in sub floor. To secure the tub to wood studs, use roofing nails immediately above the flange of the tub. To secure the tub to steel studs, use drywall screws and flat washers. (See Step 4)
Caution: Take Extra Care When Driving Nails or Screws To Avoid Damaging The Tub.
The tile or similar finished floor will be butted against the bottom of the
tub apron also holding the tub in place.
UNDERLAYMENT
FINISHED TILE FLOOR
Below is shown typical cross sections of the tub rim showing
4
typical wall constructions.
NAIL
OR
DRYWALL
SCREW
EVERY STUD
SUB FLOOR
WOOD STUDS STEEL STUDS
STUD
SHIM
DRY WALL
TILE
ROOFING NAIL
SEALANT
TUB
STEEL
STUD
SHIM
DRY WALL
TILE
SEALANT
TUB
WASHER
4" (102mm) DRYWALL SCREW
23mm 15/16"
*
64mm 2-1/2"
ROUGH
FLOOR
BELOW FLOOR ROUGH
2390.202 2391.202
23mm 15/16"
*
349mm 13-3/4"
ROUGH
FLOOR
ABOVE FLOOR ROUGH
2392.202 2393.202
DIA.
64mm 2-1/2"
DIA.
64mm 2-1/2"
64mm 2-1/2"
9" X 12" HOLE IN SUB FLOOR
FOR BELOW FLOOR ROUGH
356mm
14"
19mm
3/4"
DRAIN OUTLET
1524mm
60"
SUPPORT STRINGER
FINISHED WALL
445mm 17-1/2"
*PLUMBER NOTE: PROVIDE FULL
LENGTH SUPPORT STRINGER AT THIS POINT
229 x 305mm
60mm 2-3/8"
197mm
7-3/4"
STD. 1-1/2
FINISHED WALL
89mm 3-1/2"
FULL LENGTH
762mm
30"
19mm
48mm 1-7/8"
362mm 14-1/4"
3/4"
790043-400 (Rev. G)
51 x 102mm (2 x 4) WOOD STRINGER FULL LENGTH
LEFT HAND TUB ILLUSTRATED
RIGHT HAND TUB IS REVERSED
5
ROUGHING-IN
48mm
(1-7/8)
362mm (14-1/4)
762mm
(30)
197mm (7-3/4)
9 x 12 HOLE IN SUB-FLOOR
1524mm
FULL LENGTH SUPPORT STRINGER
OUTLINE OF SKID PATTERN
(60)
FINISHED WALL
19mm (3/4)
Princeton™ Bath
w/Integral Overflow
2390.202.ICH
2392.202.ICH
2390.202.IPB
2392.202.IPB
2391.202.ICH
2393.202.ICH
2391.202.IPB
2393.202.IPB
Installation Instructions
Observe Local Plumbing and Building Codes
Introduction:
Thank you for selecting American-Standard...products which have been the benchmarks of fine quality for over 100 years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also carefully unpack and examine your new plumbing fixture.
89mm
(3-1/2)
PROVIDE FULL
LENGTH SUPPORT
STRINGER
AT THIS POINT
PROVIDE FULL
LENGTH SUPPORT
STRINGER
AT THIS POINT
1-1/2 N.P.S.M.
1-1/2 TUBING
THREAD INSIDE
DRAIN
SHOE
THREADS
435mm
(17-1/8)
ABOVE FLOOR ROUGH
2392.202 ICH
2393.202 ICH
346mm
(13-5/8)
BELOW FLOOR ROUGH
2390.202 ICH
2391.202 ICH
LEFT HAND TUB ILLUSTRATED RIGHT TUB IS REVERSED
60mm
(2-3/8)
FINISHED
WALL
445mm
(17-1/2)
356mm
(14)
ROUGH FLOOR
ROUGH FLOOR
1
FRAMING INSTRUCTIONS
Note recess is 1527 x 813mm (60-1/8 x 32). Cut a 229 x 305mm (9 x 12) hole in sub floor for drain, centered 362mm (14-1/4) as shown for below floor rough. Locate studs as required, then ensure rough opening dimensions are proper and supports are plumb and square.
*Install stringer as shown (346mm [13-5/8] for through the floor drain or
435mm [17-1/8] for above the floor drain.)
813mm
(32)
LEVELING SUPPORT STRINGER 51 x 102mm (2 X 4)
229 x 305mm
(9 x 12) FLOOR
CUTOUT
FOR DRAIN
*
762mm
(30)
362mm
(14-1/4)
1527mm
(60-1/8)
The Drain Assembly is enclosed with tub models
IMPORTANT
listed above-locate and retain for tub installation before discarding tub carton
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
TUB WIDTH
© American Standard Inc. 2003
791174-100 Rev. G
AMERICAN STANDARD
2
DRAIN INSTALLATION
Remove Lift and Turn Stopper and Tailpiece Assembly from box and check that all
1
parts are included. Remove Lift and Turn Stopper Assembly from Tailpiece by setting Stopper to closed position, and turning Stopper Knob counter-clockwise. (Re-install Stopper after Drain installation is completed.)
Apply plumbers putty around drain hole and pipe thread compound on threaded
2
end of tailpiece. Set Tailpiece in drain hole. (Lift and Turn Stopper Assembly should be removed,
3
and reinstalled after tub installation is completed.) From underside of tub: Place Rubber Wedge Seal on Tailpiece, small end toward tub,
4
and center in hole, place Brass Washer on Tailpiece, and thread on Locking Nut, flange side first. Tighten Locking Nut to obtain a uniform seal between Wedge Seal and hole in tub.
DO NOT OVERTIGHTEN!
Final hook up to tub waste can be made using either internal threads in Tailpiece (1-1/2 tubing 1-1/2—28 thd.), or external threads on Tailpiece (1-1/2—11-1/2 NPSM) for appropriate tub fittings.
1
TURN TO
REMOVE
STOPPER IN
CLOSED POSITION
(UNSCREW STOPPER ONCE IN
CLOSED POSITION TO REMOVE)
3
SET
TAILPIECE
OPEN POSITION
LIFT AND TURN STOPPER ASSEMBLY
APPLY PIPE JOINT COMPOUND TO THREADS
APPLY PLUMBERS PUTTY
STOPPER IN
2
2
STOPPER ASSEMBLY
TAILPIECE
RUBBER DRAIN SEAL
BRASS DRAIN WASHER
BRASS DRAIN NUT
STOPPER KNOB
3
INSTALLATION
Position bathtub within the recess, check level, front to back, side to side. Also check drain clearance hole in sub floor. To secure the tub to wood studs, use roofing nails immediately above the flange of the tub. To secure the tub to steel studs, use drywall screws and flat washers. (See Step 4)
Caution: Take Extra Care When Driving Nails or Screws To Avoid Damaging The Tub.
tub apron also holding the tub in place.
NOTE: Warranty will be voided if the drain is installed after the tub has been set in place.
4
DRY WALL
ROOFING NAIL
SEALANT
TUB
The tile or similar finished floor will be butted against the bottom of the
UNDERLAYMENT
FINISHED TILE FLOOR
NAIL
OR
DRYWALL
SCREW
EVERY STUD
SUB FLOOR
Below is shown typical cross sections of the tub rim showing typical wall constructions.
STUD
SHIM
STEEL
STUD
SHIM
TILE
DRY WALL
TILE
SEALANT
TUB
WASHER
4" DRYWALL SCREW
791174-100 Rev. G
ASSEMBLE AND TIGHTEN
2 x 4 WOOD
4
STRINGER FULL LENGTH
2 x 4 WOOD STRINGER FULL LENGTH
WOOD STUDS STEEL STUDS
Loading...